From f9e04ed9a2d0077ba8cc15718f067cd547dbb10a Mon Sep 17 00:00:00 2001 From: meggert Date: Mon, 20 Mar 2023 15:42:45 +0100 Subject: [PATCH 1/2] updated gyr bias --- mission/controller/acs/AcsParameters.h | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/mission/controller/acs/AcsParameters.h b/mission/controller/acs/AcsParameters.h index fca8ed8e..5b185ea4 100644 --- a/mission/controller/acs/AcsParameters.h +++ b/mission/controller/acs/AcsParameters.h @@ -768,10 +768,10 @@ class AcsParameters : public HasParametersIF { double gyr2orientationMatrix[3][3] = {{0, 0, -1}, {0, -1, 0}, {-1, 0, 0}}; double gyr3orientationMatrix[3][3] = {{0, 0, -1}, {0, 1, 0}, {1, 0, 0}}; - double gyr0bias[3] = {0.06318149743589743, 0.4283235025641024, -0.16383500000000004}; - double gyr1bias[3] = {-0.12855128205128205, 1.6737307692307695, 1.031724358974359}; - double gyr2bias[3] = {0.15039212820512823, 0.7094475589743591, -0.22298363589743594}; - double gyr3bias[3] = {0.0021730769230769217, -0.6655897435897435, 0.034096153846153845}; + double gyr0bias[3] = {0.0, 0.4, -0.1}; + double gyr1bias[3] = {0.0956745283018868, 2.0854575471698116, 1.2505990566037737}; + double gyr2bias[3] = {0.1, 0.7, -0.2}; + double gyr3bias[3] = {-0.10721698113207549, -0.6111650943396226, 0.1716462264150944}; /* var = sigma^2, sigma = RND*sqrt(freq), following values are RND^2 and not var as freq is * assumed to be equal for the same class of sensors */ From 11c54e270f96db00ceea885f5a26d540f730c9f4 Mon Sep 17 00:00:00 2001 From: meggert Date: Mon, 20 Mar 2023 15:50:50 +0100 Subject: [PATCH 2/2] changelog --- CHANGELOG.md | 5 +++++ 1 file changed, 5 insertions(+) diff --git a/CHANGELOG.md b/CHANGELOG.md index e5ca13ae..6c7c5f65 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -21,6 +21,11 @@ will consitute of a breaking change warranting a new major release: - Fixed transition for dual power lane assemblies: When going from dual side submode to single side submode, perform logical commanding first, similarly to when going to OFF mode. +## Changed + +- Updated GYR bias values to newest measurements. This also corrects the ADIS values to always + consit of just one digit. + # [v1.38.0] 2023-03-17 eive-tmtc: v2.19.2