#ifndef MISSION_CONTROLLER_CONTROLLERDEFINITIONS_THERMALCONTROLLERDEFINITIONS_H_ #define MISSION_CONTROLLER_CONTROLLERDEFINITIONS_THERMALCONTROLLERDEFINITIONS_H_ #include #include namespace thermalControllerDefinitions { enum SetIds : uint32_t { SENSOR_TEMPERATURES, DEVICE_TEMPERATURES, SUS_TEMPERATURES, COMPONENT_TEMPERATURES }; enum PoolIds : lp_id_t { SENSOR_PLOC_HEATSPREADER, SENSOR_PLOC_MISSIONBOARD, SENSOR_4K_CAMERA, SENSOR_DAC_HEATSPREADER, SENSOR_STARTRACKER, SENSOR_RW1, SENSOR_DRO, SENSOR_SCEX, SENSOR_X8, SENSOR_HPA, SENSOR_TX_MODUL, SENSOR_MPA, SENSOR_ACU, SENSOR_PLPCDU_HEATSPREADER, SENSOR_TCS_BOARD, SENSOR_MAGNETTORQUER, SENSOR_TMP1075_1, SENSOR_TMP1075_2, SUS_0_N_LOC_XFYFZM_PT_XF, SUS_6_R_LOC_XFYBZM_PT_XF, SUS_1_N_LOC_XBYFZM_PT_XB, SUS_7_R_LOC_XBYBZM_PT_XB, SUS_2_N_LOC_XFYBZB_PT_YB, SUS_8_R_LOC_XBYBZB_PT_YB, SUS_3_N_LOC_XFYBZF_PT_YF, SUS_9_R_LOC_XBYBZB_PT_YF, SUS_4_N_LOC_XMYFZF_PT_ZF, SUS_10_N_LOC_XMYBZF_PT_ZF, SUS_5_N_LOC_XFYMZB_PT_ZB, SUS_11_R_LOC_XBYMZB_PT_ZB, COMPONENT_RW, TEMP_Q7S, TEMP_BATTERY, TEMP_RW0, TEMP_RW1, TEMP_RW2, TEMP_RW3, TEMP_STAR_TRACKER, TEMP_SYRLINKS_POWER_AMPLIFIER, TEMP_SYRLINKS_BASEBAND_BOARD, TEMP_MGT, }; /** * @brief This dataset can be used to store the collected temperatures of all temperature sensors */ class SensorTemperatures : public StaticLocalDataSet<18> { public: SensorTemperatures(HasLocalDataPoolIF* owner) : StaticLocalDataSet(owner, SENSOR_TEMPERATURES) {} SensorTemperatures(object_id_t objectId) : StaticLocalDataSet(sid_t(objectId, SENSOR_TEMPERATURES)) {} lp_var_t sensor_ploc_heatspreader = lp_var_t(sid.objectId, PoolIds::SENSOR_PLOC_HEATSPREADER, this); lp_var_t sensor_ploc_missionboard = lp_var_t(sid.objectId, PoolIds::SENSOR_PLOC_MISSIONBOARD, this); lp_var_t sensor_4k_camera = lp_var_t(sid.objectId, PoolIds::SENSOR_4K_CAMERA, this); lp_var_t sensor_dac_heatspreader = lp_var_t(sid.objectId, PoolIds::SENSOR_DAC_HEATSPREADER, this); lp_var_t sensor_startracker = lp_var_t(sid.objectId, PoolIds::SENSOR_STARTRACKER, this); lp_var_t sensor_rw1 = lp_var_t(sid.objectId, PoolIds::SENSOR_RW1, this); lp_var_t sensor_dro = lp_var_t(sid.objectId, PoolIds::SENSOR_DRO, this); lp_var_t sensor_scex = lp_var_t(sid.objectId, PoolIds::SENSOR_SCEX, this); lp_var_t sensor_x8 = lp_var_t(sid.objectId, PoolIds::SENSOR_X8, this); lp_var_t sensor_hpa = lp_var_t(sid.objectId, PoolIds::SENSOR_HPA, this); lp_var_t sensor_tx_modul = lp_var_t(sid.objectId, PoolIds::SENSOR_TX_MODUL, this); lp_var_t sensor_mpa = lp_var_t(sid.objectId, PoolIds::SENSOR_MPA, this); lp_var_t sensor_acu = lp_var_t(sid.objectId, PoolIds::SENSOR_ACU, this); lp_var_t sensor_plpcdu_heatspreader = lp_var_t(sid.objectId, PoolIds::SENSOR_PLPCDU_HEATSPREADER, this); lp_var_t sensor_tcs_board = lp_var_t(sid.objectId, PoolIds::SENSOR_TCS_BOARD, this); lp_var_t sensor_magnettorquer = lp_var_t(sid.objectId, PoolIds::SENSOR_MAGNETTORQUER, this); lp_var_t sensor_tmp1075_1 = lp_var_t(sid.objectId, PoolIds::SENSOR_TMP1075_1, this); lp_var_t sensor_tmp1075_2 = lp_var_t(sid.objectId, PoolIds::SENSOR_TMP1075_2, this); }; /** * @brief This dataset can be used to store the collected temperatures of all device temperature * sensors */ class DeviceTemperatures : public StaticLocalDataSet<1> { public: DeviceTemperatures(HasLocalDataPoolIF* owner) : StaticLocalDataSet(owner, SENSOR_TEMPERATURES) {} DeviceTemperatures(object_id_t objectId) : StaticLocalDataSet(sid_t(objectId, DEVICE_TEMPERATURES)) {} lp_var_t q7s = lp_var_t(sid.objectId, PoolIds::SUS_0_N_LOC_XFYFZM_PT_XF, this); }; /** * @brief This dataset can be used to store the collected temperatures of all SUS temperature * sensors */ class SusTemperatures : public StaticLocalDataSet<12> { public: SusTemperatures(HasLocalDataPoolIF* owner) : StaticLocalDataSet(owner, SUS_TEMPERATURES) {} SusTemperatures(object_id_t objectId) : StaticLocalDataSet(sid_t(objectId, DEVICE_TEMPERATURES)) {} lp_var_t sus_0_n_loc_xfyfzm_pt_xf = lp_var_t(sid.objectId, PoolIds::SUS_0_N_LOC_XFYFZM_PT_XF, this); lp_var_t sus_6_r_loc_xfybzm_pt_xf = lp_var_t(sid.objectId, PoolIds::SUS_6_R_LOC_XFYBZM_PT_XF, this); lp_var_t sus_1_n_loc_xbyfzm_pt_xb = lp_var_t(sid.objectId, PoolIds::SUS_1_N_LOC_XBYFZM_PT_XB, this); lp_var_t sus_7_r_loc_xbybzm_pt_xb = lp_var_t(sid.objectId, PoolIds::SUS_7_R_LOC_XBYBZM_PT_XB, this); lp_var_t sus_2_n_loc_xfybzb_pt_yb = lp_var_t(sid.objectId, PoolIds::SUS_2_N_LOC_XFYBZB_PT_YB, this); lp_var_t sus_8_r_loc_xbybzb_pt_yb = lp_var_t(sid.objectId, PoolIds::SUS_8_R_LOC_XBYBZB_PT_YB, this); lp_var_t sus_3_n_loc_xfybzf_pt_yf = lp_var_t(sid.objectId, PoolIds::SUS_3_N_LOC_XFYBZF_PT_YF, this); lp_var_t sus_9_r_loc_xbybzb_pt_yf = lp_var_t(sid.objectId, PoolIds::SUS_9_R_LOC_XBYBZB_PT_YF, this); lp_var_t sus_4_n_loc_xmyfzf_pt_zf = lp_var_t(sid.objectId, PoolIds::SUS_4_N_LOC_XMYFZF_PT_ZF, this); lp_var_t sus_10_n_loc_xmybzf_pt_zf = lp_var_t(sid.objectId, PoolIds::SUS_10_N_LOC_XMYBZF_PT_ZF, this); lp_var_t sus_5_n_loc_xfymzb_pt_zb = lp_var_t(sid.objectId, PoolIds::SUS_5_N_LOC_XFYMZB_PT_ZB, this); lp_var_t sus_11_r_loc_xbymzb_pt_zb = lp_var_t(sid.objectId, PoolIds::SUS_11_R_LOC_XBYMZB_PT_ZB, this); }; /** * @brief This dataset can be used to store the collected temperatures of all components */ class ComponentTemperatures : public StaticLocalDataSet<2> { public: ComponentTemperatures(HasLocalDataPoolIF* owner) : StaticLocalDataSet(owner, COMPONENT_TEMPERATURES) {} ComponentTemperatures(object_id_t objectId) : StaticLocalDataSet(sid_t(objectId, COMPONENT_TEMPERATURES)) {} lp_var_t rw = lp_var_t(sid.objectId, PoolIds::COMPONENT_RW, this); }; } // namespace thermalControllerDefinitions #endif /* MISSION_CONTROLLER_CONTROLLERDEFINITIONS_THERMALCONTROLLERDEFINITIONS_H_ */