#ifndef MISSION_TCS_TMP1075DEFINITIONS_H_
|
|
#define MISSION_TCS_TMP1075DEFINITIONS_H_
|
|
|
|
#include <fsfw/datapoollocal/StaticLocalDataSet.h>
|
|
|
|
#include <cstdint>
|
|
|
|
#include "fsfw/devicehandlers/DeviceHandlerIF.h"
|
|
|
|
namespace TMP1075 {
|
|
static const uint8_t TEMP_REG_ADDR = 0x0;
|
|
static const uint8_t CFGR_ADDR = 0x1;
|
|
|
|
/* Writing this information to the configuration register sets the tmp1075
|
|
* to shutdown mode and starts a single temperature conversion */
|
|
static const uint16_t ONE_SHOT_MODE = 0x8100;
|
|
|
|
static const DeviceCommandId_t NONE = 0x0; // Set when no command is pending
|
|
static const DeviceCommandId_t GET_TEMP = 0x1;
|
|
static const DeviceCommandId_t START_ADC_CONVERSION = 0x2;
|
|
|
|
static const uint8_t GET_TEMP_REPLY_SIZE = 2;
|
|
static const uint8_t CFGR_CMD_SIZE = 3;
|
|
static const uint8_t POINTER_REG_SIZE = 1;
|
|
|
|
static const uint32_t TMP1075_DATA_SET_ID = GET_TEMP;
|
|
|
|
static const uint8_t MAX_REPLY_LENGTH = GET_TEMP_REPLY_SIZE;
|
|
|
|
enum Tmp1075PoolIds : lp_id_t { TEMPERATURE_C_TMP1075 };
|
|
|
|
class Tmp1075Dataset : public StaticLocalDataSet<2> {
|
|
public:
|
|
Tmp1075Dataset(HasLocalDataPoolIF* owner) : StaticLocalDataSet(owner, TMP1075_DATA_SET_ID) {}
|
|
|
|
Tmp1075Dataset(object_id_t objectId) : StaticLocalDataSet(sid_t(objectId, TMP1075_DATA_SET_ID)) {}
|
|
|
|
lp_var_t<float> temperatureCelcius = lp_var_t<float>(sid.objectId, TEMPERATURE_C_TMP1075, this);
|
|
};
|
|
} // namespace TMP1075
|
|
|
|
#endif /* MISSION_TCS_TMP1075DEFINITIONS_H_ */
|