2023-03-13 10:31:27 +01:00
|
|
|
import enum
|
2022-05-23 17:50:08 +02:00
|
|
|
from typing import Optional
|
2023-01-19 13:21:12 +01:00
|
|
|
import struct
|
2022-05-23 17:50:08 +02:00
|
|
|
|
2022-11-29 16:53:29 +01:00
|
|
|
from eive_tmtc.config.definitions import CustomServiceList
|
2023-03-14 10:11:01 +01:00
|
|
|
from eive_tmtc.pus_tm.defs import PrintWrapper
|
2022-05-23 17:50:08 +02:00
|
|
|
from spacepackets.ecss import PusTelecommand
|
2022-08-12 10:18:21 +02:00
|
|
|
from tmtccmd.config import TmtcDefinitionWrapper, OpCodeEntry
|
|
|
|
from tmtccmd.config.tmtc import tmtc_definitions_provider
|
2022-07-04 15:22:53 +02:00
|
|
|
|
2023-11-10 19:23:06 +01:00
|
|
|
from tmtccmd.tmtc import DefaultPusQueueHelper
|
2022-07-08 16:25:46 +02:00
|
|
|
from tmtccmd.util import ObjectIdU32
|
2023-11-10 19:23:06 +01:00
|
|
|
from tmtccmd.pus.s200_fsfw_mode import Mode, pack_mode_data, Subservice
|
2022-11-29 16:53:29 +01:00
|
|
|
import eive_tmtc.config.object_ids as oids
|
|
|
|
from eive_tmtc.config.object_ids import get_object_ids
|
2023-05-25 11:31:06 +02:00
|
|
|
from tmtccmd.fsfw.tmtc_printer import FsfwTmTcPrinter
|
2022-05-23 17:50:08 +02:00
|
|
|
|
|
|
|
RTD_IDS = [
|
|
|
|
oids.RTD_0_PLOC_HSPD,
|
|
|
|
oids.RTD_1_PLOC_MISSIONBRD,
|
|
|
|
oids.RTD_2_4K_CAM,
|
|
|
|
oids.RTD_3_DAC_HSPD,
|
|
|
|
oids.RTD_4_STR,
|
|
|
|
oids.RTD_5_RW1_MX_MY,
|
|
|
|
oids.RTD_6_DRO,
|
|
|
|
oids.RTD_7_SCEX,
|
|
|
|
oids.RTD_8_X8,
|
|
|
|
oids.RTD_9_HPA,
|
|
|
|
oids.RTD_10_PL_TX,
|
|
|
|
oids.RTD_11_MPA,
|
|
|
|
oids.RTD_12_ACU,
|
|
|
|
oids.RTD_13_PLPCDU_HSPD,
|
|
|
|
oids.RTD_14_TCS_BRD,
|
2022-05-23 18:34:28 +02:00
|
|
|
oids.RTD_15_IMTQ,
|
2022-05-23 17:50:08 +02:00
|
|
|
]
|
|
|
|
|
2023-03-14 10:11:01 +01:00
|
|
|
RTD_NAMES = {
|
|
|
|
oids.RTD_0_PLOC_HSPD: "RTD 0 PLOC Heatspreader",
|
|
|
|
oids.RTD_1_PLOC_MISSIONBRD: "RTD 1 PLOC Missionboard",
|
|
|
|
oids.RTD_2_4K_CAM: "RTD 2 4K Camera",
|
|
|
|
oids.RTD_3_DAC_HSPD: "RTD 3 DAC HSPC",
|
|
|
|
oids.RTD_4_STR: "RTD 4 Startracker",
|
|
|
|
oids.RTD_5_RW1_MX_MY: "RTD 5 RW1 MX MY",
|
|
|
|
oids.RTD_6_DRO: "RTD 6 DRO",
|
|
|
|
oids.RTD_7_SCEX: "RTD 7 SCEX",
|
|
|
|
oids.RTD_8_X8: "RTD 8 X8",
|
|
|
|
oids.RTD_9_HPA: "RTD 9 HPA",
|
|
|
|
oids.RTD_10_PL_TX: "RTD 10 PL TX",
|
|
|
|
oids.RTD_11_MPA: "RTD 11 MPA",
|
|
|
|
oids.RTD_12_ACU: "RTD 12 ACU",
|
|
|
|
oids.RTD_13_PLPCDU_HSPD: "RTD 13 PL PCDU Heatspreader",
|
|
|
|
oids.RTD_14_TCS_BRD: "RTD 14 TCS Board",
|
|
|
|
oids.RTD_15_IMTQ: "RTD 15 iMTQ",
|
|
|
|
}
|
|
|
|
|
2022-05-23 17:50:08 +02:00
|
|
|
|
2023-01-19 13:21:12 +01:00
|
|
|
class CommandId:
|
|
|
|
WRITE_CONFIG = 6
|
|
|
|
|
|
|
|
|
2023-03-13 10:35:33 +01:00
|
|
|
class RtdId(enum.IntEnum):
|
|
|
|
RTD_0_PLOC_HSPC = 0
|
|
|
|
RTD_1_PLOC_MISSIONBRD = 1
|
|
|
|
RTD_2_4K_CAM = 2
|
|
|
|
RTD_3_DAC_HSPD = 3
|
|
|
|
RTD_4_STR = 4
|
|
|
|
RTD_5_RW1_MX_MY = 5
|
|
|
|
RTD_6_DRO = 6
|
|
|
|
RTD_7_SCEX = 7
|
|
|
|
RTD_8_X8 = 8
|
|
|
|
RTD_9_HPA = 9
|
|
|
|
RTD_10_PL_TX = 10
|
|
|
|
RTD_11_MPA = 11
|
|
|
|
RTD_12_ACU = 12
|
|
|
|
RTD_13_PLPCDU_HSPD = 13
|
|
|
|
RTD_14_TCS_BRD = 14
|
|
|
|
RTD_15_IMTQ = 15
|
|
|
|
|
|
|
|
|
2023-03-13 10:31:27 +01:00
|
|
|
class SetId(enum.IntEnum):
|
|
|
|
TEMPERATURE = 1
|
|
|
|
|
|
|
|
|
2023-11-22 10:17:05 +01:00
|
|
|
class CmdStr:
|
|
|
|
ON = "on"
|
|
|
|
OFF = "off"
|
|
|
|
NORMAL = "normal"
|
|
|
|
WRITE_CONFIG = "write_cfg"
|
2022-05-23 17:50:08 +02:00
|
|
|
|
|
|
|
|
2023-11-22 10:17:05 +01:00
|
|
|
class CmdInfo:
|
2022-05-23 17:50:08 +02:00
|
|
|
ON = "Switch handler on"
|
|
|
|
OFF = "Switch handler off"
|
|
|
|
NORMAL = "Switch handler normal"
|
2023-01-19 13:21:12 +01:00
|
|
|
WRITE_CONFIG = "Write config"
|
2022-05-23 17:50:08 +02:00
|
|
|
|
|
|
|
|
2022-08-12 10:18:21 +02:00
|
|
|
@tmtc_definitions_provider
|
|
|
|
def specify_rtd_cmds(defs: TmtcDefinitionWrapper):
|
2022-07-05 02:12:54 +02:00
|
|
|
oce = OpCodeEntry()
|
2023-11-22 10:17:05 +01:00
|
|
|
oce.add(keys=CmdStr.ON, info=CmdInfo.ON)
|
|
|
|
oce.add(keys=CmdStr.NORMAL, info=CmdInfo.NORMAL)
|
|
|
|
oce.add(keys=CmdStr.OFF, info=CmdInfo.OFF)
|
|
|
|
oce.add(keys=CmdStr.WRITE_CONFIG, info=CmdInfo.WRITE_CONFIG)
|
2022-07-05 02:12:54 +02:00
|
|
|
defs.add_service(
|
|
|
|
name=CustomServiceList.RTD.value, info="RTD commands", op_code_entry=oce
|
2022-05-23 17:50:08 +02:00
|
|
|
)
|
|
|
|
|
|
|
|
|
2022-08-08 16:32:18 +02:00
|
|
|
def pack_rtd_commands(
|
2023-11-22 10:17:05 +01:00
|
|
|
cmd_str: str, object_id: Optional[ObjectIdU32], q: DefaultPusQueueHelper
|
2022-08-08 16:32:18 +02:00
|
|
|
):
|
2022-05-23 17:50:08 +02:00
|
|
|
if object_id is not None and object_id not in RTD_IDS:
|
|
|
|
print("Specified object ID not a valid RTD ID")
|
|
|
|
object_id = None
|
|
|
|
if object_id is None:
|
|
|
|
tgt_rtd_idx = prompt_rtd_idx()
|
|
|
|
object_id_dict = get_object_ids()
|
|
|
|
object_id = object_id_dict.get(RTD_IDS[tgt_rtd_idx])
|
2023-11-22 10:17:05 +01:00
|
|
|
if cmd_str == CmdStr.ON:
|
2023-01-16 15:05:33 +01:00
|
|
|
app_data = pack_mode_data(object_id=object_id.as_bytes, mode=Mode.ON, submode=0)
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(
|
|
|
|
PusTelecommand(
|
2023-01-17 18:37:16 +01:00
|
|
|
service=200, subservice=Subservice.TC_MODE_COMMAND, app_data=app_data
|
2022-07-04 15:22:53 +02:00
|
|
|
)
|
2022-05-23 17:50:08 +02:00
|
|
|
)
|
2023-11-22 10:17:05 +01:00
|
|
|
if cmd_str == CmdStr.NORMAL:
|
2022-05-23 18:34:28 +02:00
|
|
|
app_data = pack_mode_data(
|
2023-01-16 15:05:33 +01:00
|
|
|
object_id=object_id.as_bytes, mode=Mode.NORMAL, submode=0
|
2022-05-23 18:34:28 +02:00
|
|
|
)
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(
|
|
|
|
PusTelecommand(
|
2023-01-17 18:37:16 +01:00
|
|
|
service=200, subservice=Subservice.TC_MODE_COMMAND, app_data=app_data
|
2022-07-04 15:22:53 +02:00
|
|
|
)
|
2022-05-23 17:50:08 +02:00
|
|
|
)
|
2023-11-22 10:17:05 +01:00
|
|
|
if cmd_str == CmdStr.OFF:
|
2022-05-23 18:34:28 +02:00
|
|
|
app_data = pack_mode_data(
|
2023-01-16 15:05:33 +01:00
|
|
|
object_id=object_id.as_bytes, mode=Mode.OFF, submode=0
|
2022-05-23 18:34:28 +02:00
|
|
|
)
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(
|
|
|
|
PusTelecommand(
|
2023-01-17 18:37:16 +01:00
|
|
|
service=200, subservice=Subservice.TC_MODE_COMMAND, app_data=app_data
|
2022-07-04 15:22:53 +02:00
|
|
|
)
|
2022-05-23 17:50:08 +02:00
|
|
|
)
|
2023-11-22 10:17:05 +01:00
|
|
|
if cmd_str in CmdStr.WRITE_CONFIG:
|
2023-01-20 10:35:30 +01:00
|
|
|
command = object_id.as_bytes + struct.pack("!I", CommandId.WRITE_CONFIG)
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(PusTelecommand(service=8, subservice=128, app_data=command))
|
2022-05-23 17:50:08 +02:00
|
|
|
|
|
|
|
|
2023-05-24 13:44:45 +02:00
|
|
|
def handle_rtd_hk(object_id: bytes, hk_data: bytes, pw: PrintWrapper):
|
2023-03-14 10:11:01 +01:00
|
|
|
rtd_name = RTD_NAMES.get(object_id)
|
|
|
|
if rtd_name is None:
|
|
|
|
rtd_name = "unknown RTD device"
|
|
|
|
pw.dlog(f"Received RTD HK for RTD {rtd_name} with object ID {object_id}")
|
|
|
|
fmt_str = "!ffBB"
|
|
|
|
fmt_len = struct.calcsize(fmt_str)
|
|
|
|
(rtd_val, temp_celcius, last_err_byte, error_byte) = struct.unpack(
|
|
|
|
fmt_str, hk_data[0 : 0 + fmt_len]
|
|
|
|
)
|
|
|
|
pw.dlog(f"Temperature Celcius: {temp_celcius}")
|
|
|
|
pw.dlog(f"RTD Value: {rtd_val}")
|
|
|
|
pw.dlog(f"Error Byte: {error_byte}")
|
|
|
|
pw.dlog(f"Last Error Byte: {last_err_byte}")
|
2023-05-24 13:44:45 +02:00
|
|
|
FsfwTmTcPrinter.get_validity_buffer(hk_data[fmt_len:], 4)
|
2023-03-14 10:11:01 +01:00
|
|
|
|
|
|
|
|
2022-05-23 17:50:08 +02:00
|
|
|
def prompt_rtd_idx():
|
|
|
|
while True:
|
|
|
|
rtd_idx = input("Please specify RTD index [0-15]: ")
|
|
|
|
if not rtd_idx.isdigit():
|
|
|
|
print("Invalid input")
|
|
|
|
continue
|
|
|
|
rtd_idx = int(rtd_idx)
|
|
|
|
if rtd_idx < 0 or rtd_idx > 15:
|
|
|
|
print("Invalid device index")
|
|
|
|
continue
|
|
|
|
return rtd_idx
|