2020-12-29 11:29:03 +01:00
|
|
|
# -*- coding: utf-8 -*-
|
2022-05-23 11:24:55 +02:00
|
|
|
"""ACU commands
|
|
|
|
@author J. Meier, R. Mueller
|
2020-12-29 11:29:03 +01:00
|
|
|
@date 21.12.2020
|
|
|
|
"""
|
2022-11-14 10:56:14 +01:00
|
|
|
import struct
|
2022-06-10 11:02:08 +02:00
|
|
|
|
2022-05-23 11:24:55 +02:00
|
|
|
from config.definitions import CustomServiceList
|
2022-11-14 10:56:14 +01:00
|
|
|
from pus_tm.defs import PrintWrapper
|
2022-08-27 16:28:33 +02:00
|
|
|
from tmtc.power.common_power import (
|
2022-10-18 10:44:32 +02:00
|
|
|
pack_common_gomspace_cmds,
|
2022-08-27 16:28:33 +02:00
|
|
|
add_gomspace_cmd_defs,
|
|
|
|
req_hk_cmds,
|
2022-10-18 10:44:32 +02:00
|
|
|
pack_common_power_cmds,
|
2022-10-18 11:01:01 +02:00
|
|
|
SetIds,
|
2022-11-14 10:56:14 +01:00
|
|
|
OBC_ENDIANNESS,
|
|
|
|
unpack_array_in_data,
|
2022-08-27 16:28:33 +02:00
|
|
|
)
|
2022-08-12 10:18:21 +02:00
|
|
|
from tmtccmd.config import TmtcDefinitionWrapper, OpCodeEntry
|
|
|
|
from tmtccmd.config.tmtc import tmtc_definitions_provider
|
2022-07-04 15:22:53 +02:00
|
|
|
|
2022-08-08 16:32:18 +02:00
|
|
|
from tmtccmd.tc import DefaultPusQueueHelper
|
2022-05-23 11:24:55 +02:00
|
|
|
import gomspace.gomspace_common as gs
|
|
|
|
from config.object_ids import ACU_HANDLER_ID
|
2022-07-08 16:25:46 +02:00
|
|
|
from tmtccmd.util import ObjectIdU32
|
2022-05-23 11:24:55 +02:00
|
|
|
|
|
|
|
|
|
|
|
class ACUConfigTable:
|
|
|
|
mppt_mode = gs.TableEntry(bytearray([0x00, 0x00]), gs.TableEntry.uint8_size)
|
|
|
|
mppt_d_mode = gs.TableEntry(bytearray([0x00, 0x01]), gs.TableEntry.uint8_size)
|
|
|
|
vboost = gs.TableEntry(bytearray([0x00, 0x02]), gs.TableEntry.uint16_size)
|
|
|
|
vbat_max_hi = gs.TableEntry(bytearray([0x00, 0x10]), gs.TableEntry.uint16_size)
|
|
|
|
vbat_max_lo = gs.TableEntry(bytearray([0x00, 0x12]), gs.TableEntry.uint16_size)
|
|
|
|
ov_mode = gs.TableEntry(bytearray([0x00, 0x1A]), gs.TableEntry.uint8_size)
|
|
|
|
|
|
|
|
|
|
|
|
class ACUHkTable:
|
|
|
|
temperature1 = gs.TableEntry(bytearray([0x00, 0x1C]), gs.TableEntry.uint16_size)
|
|
|
|
temperature2 = gs.TableEntry(bytearray([0x00, 0x1D]), gs.TableEntry.uint16_size)
|
|
|
|
temperature3 = gs.TableEntry(bytearray([0x00, 0x1E]), gs.TableEntry.uint16_size)
|
|
|
|
# Ground WDT value (remaining seconds until reboot)
|
|
|
|
wdt_gnd_left = gs.TableEntry(bytearray([0x00, 0x74]), gs.TableEntry.uint32_size)
|
|
|
|
|
|
|
|
|
|
|
|
class OpCodes:
|
|
|
|
TEST = ["0", "test"]
|
|
|
|
|
|
|
|
|
|
|
|
class Info:
|
|
|
|
TEST = "ACU Test"
|
|
|
|
|
|
|
|
|
2022-08-12 10:18:21 +02:00
|
|
|
@tmtc_definitions_provider
|
|
|
|
def add_acu_cmds(defs: TmtcDefinitionWrapper):
|
2022-07-05 02:12:54 +02:00
|
|
|
oce = OpCodeEntry()
|
2022-08-27 01:01:04 +02:00
|
|
|
add_gomspace_cmd_defs(oce)
|
2022-08-27 16:28:33 +02:00
|
|
|
|
2022-07-05 02:12:54 +02:00
|
|
|
oce.add(keys=OpCodes.TEST, info=Info.TEST)
|
|
|
|
defs.add_service(
|
2022-05-23 11:24:55 +02:00
|
|
|
name=CustomServiceList.ACU.value,
|
2022-05-23 11:25:33 +02:00
|
|
|
info="ACU Device",
|
2022-07-05 02:12:54 +02:00
|
|
|
op_code_entry=oce,
|
2022-05-23 11:24:55 +02:00
|
|
|
)
|
|
|
|
|
|
|
|
|
2022-08-08 16:32:18 +02:00
|
|
|
def pack_acu_commands(object_id: ObjectIdU32, q: DefaultPusQueueHelper, op_code: str):
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("Handling ACU command")
|
2022-10-18 10:44:32 +02:00
|
|
|
pack_common_power_cmds("ACU", object_id, q, op_code)
|
|
|
|
pack_common_gomspace_cmds("ACU", object_id, q, op_code)
|
2022-08-27 16:28:33 +02:00
|
|
|
acu_req_hk_cmds(q, op_code)
|
2022-07-04 15:22:53 +02:00
|
|
|
pack_test_cmds(object_id=object_id, q=q)
|
2022-05-23 11:24:55 +02:00
|
|
|
|
2020-12-29 11:29:03 +01:00
|
|
|
|
2022-08-27 16:28:33 +02:00
|
|
|
def acu_req_hk_cmds(q: DefaultPusQueueHelper, op_code: str):
|
2022-10-18 11:01:01 +02:00
|
|
|
req_hk_cmds("ACU", q, op_code, ACU_HANDLER_ID, [SetIds.CORE, SetIds.AUX])
|
2022-08-27 16:28:33 +02:00
|
|
|
|
|
|
|
|
2020-12-29 11:29:03 +01:00
|
|
|
class ACUTestProcedure:
|
|
|
|
"""
|
|
|
|
@brief Use this class to define the tests to perform for the ACU.
|
|
|
|
@details Setting all to True will run all tests.
|
|
|
|
Setting all to False will only run the tests set to True.
|
|
|
|
"""
|
2022-01-18 14:03:56 +01:00
|
|
|
|
2020-12-29 11:29:03 +01:00
|
|
|
all = False
|
|
|
|
reboot = False
|
|
|
|
read_gnd_wdt = False
|
|
|
|
gnd_wdt_reset = False
|
|
|
|
ping = False
|
|
|
|
read_temperature1 = False
|
|
|
|
read_temperature2 = False
|
2022-05-23 11:24:55 +02:00
|
|
|
read_temperature3 = False
|
|
|
|
read_mppt_mode = False
|
|
|
|
read_vboost = False
|
|
|
|
read_vbat_max_hi = False
|
|
|
|
read_vbat_max_lo = False
|
|
|
|
read_ov_mode = False
|
|
|
|
off = False
|
2020-12-29 11:29:03 +01:00
|
|
|
|
|
|
|
|
2022-08-08 16:32:18 +02:00
|
|
|
def pack_test_cmds(object_id: ObjectIdU32, q: DefaultPusQueueHelper):
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.reboot:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Reboot")
|
|
|
|
q.add_pus_tc(gs.pack_reboot_command(object_id))
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.read_gnd_wdt:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Reading ground watchdog timer value")
|
|
|
|
q.add_pus_tc(
|
|
|
|
gs.pack_get_param_command(
|
|
|
|
object_id.as_bytes,
|
2022-09-01 16:58:31 +02:00
|
|
|
gs.TableIds.HK,
|
2022-07-04 15:22:53 +02:00
|
|
|
ACUHkTable.wdt_gnd_left.parameter_address,
|
|
|
|
ACUHkTable.wdt_gnd_left.parameter_size,
|
|
|
|
)
|
2021-08-03 15:28:28 +02:00
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.gnd_wdt_reset:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Testing ground watchdog reset")
|
|
|
|
q.add_pus_tc(gs.pack_gnd_wdt_reset_command(object_id))
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.ping:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Ping Test")
|
2020-12-29 11:29:03 +01:00
|
|
|
ping_data = bytearray([0, 1, 2, 3, 4, 5, 6, 7, 8, 9])
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(gs.pack_ping_command(object_id, ping_data))
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.read_temperature3:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Reading temperature 3")
|
|
|
|
q.add_pus_tc(
|
|
|
|
gs.pack_get_param_command(
|
|
|
|
object_id.as_bytes,
|
2022-09-01 16:58:31 +02:00
|
|
|
gs.TableIds.HK,
|
2022-07-04 15:22:53 +02:00
|
|
|
ACUHkTable.temperature3.parameter_address,
|
|
|
|
ACUHkTable.temperature3.parameter_size,
|
|
|
|
)
|
2022-01-18 14:03:56 +01:00
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.read_vboost:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Reading vboost value")
|
|
|
|
q.add_pus_tc(
|
|
|
|
gs.pack_get_param_command(
|
|
|
|
object_id.as_bytes,
|
2022-09-01 16:58:31 +02:00
|
|
|
gs.TableIds.CONFIG,
|
2022-07-04 15:22:53 +02:00
|
|
|
ACUConfigTable.vboost.parameter_address,
|
|
|
|
ACUConfigTable.vboost.parameter_size,
|
|
|
|
)
|
2022-01-18 14:03:56 +01:00
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.read_vbat_max_hi:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Reading vbat_max_hi")
|
|
|
|
q.add_pus_tc(
|
|
|
|
gs.pack_get_param_command(
|
|
|
|
object_id.as_bytes,
|
2022-09-01 16:58:31 +02:00
|
|
|
gs.TableIds.CONFIG,
|
2022-07-04 15:22:53 +02:00
|
|
|
ACUConfigTable.vbat_max_hi.parameter_address,
|
|
|
|
ACUConfigTable.vbat_max_hi.parameter_size,
|
|
|
|
)
|
2022-01-18 14:03:56 +01:00
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.read_vbat_max_lo:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Reading vbat_max_lo")
|
|
|
|
q.add_pus_tc(
|
|
|
|
gs.pack_get_param_command(
|
|
|
|
object_id.as_bytes,
|
2022-09-01 16:58:31 +02:00
|
|
|
gs.TableIds.CONFIG,
|
2022-07-04 15:22:53 +02:00
|
|
|
ACUConfigTable.vbat_max_lo.parameter_address,
|
|
|
|
ACUConfigTable.vbat_max_lo.parameter_size,
|
|
|
|
)
|
2022-01-18 14:03:56 +01:00
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
if ACUTestProcedure.all or ACUTestProcedure.read_ov_mode:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("ACU: Reading ov_mode")
|
|
|
|
q.add_pus_tc(
|
|
|
|
gs.pack_get_param_command(
|
|
|
|
object_id.as_bytes,
|
2022-09-01 16:58:31 +02:00
|
|
|
gs.TableIds.CONFIG,
|
2022-07-04 15:22:53 +02:00
|
|
|
ACUConfigTable.ov_mode.parameter_address,
|
|
|
|
ACUConfigTable.ov_mode.parameter_size,
|
|
|
|
)
|
2022-01-18 14:03:56 +01:00
|
|
|
)
|
2022-11-14 10:56:14 +01:00
|
|
|
|
|
|
|
|
|
|
|
def acu_config_table_handler(pw: PrintWrapper, custom_data: bytes):
|
|
|
|
mppt_mode = custom_data[0]
|
|
|
|
mppt_delta_mode = custom_data[1]
|
|
|
|
vboost_list = unpack_array_in_data(custom_data, 0x02, 2, 6, "H")
|
|
|
|
vbat_max_hi = struct.unpack(f"{OBC_ENDIANNESS}H", custom_data[0x10 : 0x10 + 2])[0]
|
|
|
|
vbat_max_lo = struct.unpack(f"{OBC_ENDIANNESS}H", custom_data[0x12 : 0x12 + 2])[0]
|
|
|
|
mppt_period = struct.unpack(f"{OBC_ENDIANNESS}I", custom_data[0x14 : 0x14 + 4])[0]
|
|
|
|
max_dv = struct.unpack(f"{OBC_ENDIANNESS}H", custom_data[0x18 : 0x18 + 2])[0]
|
|
|
|
ov_mode = custom_data[0x1A]
|
|
|
|
pw.dlog(f"{'mppt_mode'.ljust(15)}: {mppt_mode}")
|
|
|
|
pw.dlog(f"{'mppt_delta_mode'.ljust(15)}: {mppt_delta_mode}")
|
|
|
|
pw.dlog(f"{'vboost_list'.ljust(15)}: {vboost_list}")
|
|
|
|
pw.dlog(f"{'vbat_max_hi'.ljust(15)}: {vbat_max_hi}")
|
|
|
|
pw.dlog(f"{'vbat_max_lo'.ljust(15)}: {vbat_max_lo}")
|
|
|
|
pw.dlog(f"{'mppt_period'.ljust(15)}: {mppt_period}")
|
|
|
|
pw.dlog(f"{'max_dv'.ljust(15)}: {max_dv}")
|
|
|
|
pw.dlog(f"{'ov_mode'.ljust(15)}: {ov_mode}")
|