# -*- coding: utf-8 -*- """ @file tmp1075.py @brief TMP1075 tests @author J. Meier @date 06.01.2021 """ import enum import struct from tmtccmd.config import CmdTreeNode from eive_tmtc.config.definitions import CustomServiceList from eive_tmtc.pus_tm.defs import PrintWrapper from spacepackets.ecss.tc import PusTelecommand from tmtccmd.config.tmtc import ( tmtc_definitions_provider, TmtcDefinitionWrapper, OpCodeEntry, ) from tmtccmd.fsfw.tmtc_printer import FsfwTmTcPrinter from tmtccmd.tmtc import DefaultPusQueueHelper from tmtccmd.pus.s200_fsfw_mode import Mode, pack_mode_data from tmtccmd.pus.tc.s3_fsfw_hk import create_request_one_hk_command, make_sid from tmtccmd.util import ObjectIdU32 class CmdStr: OFF = "off" ON = "on" NML = "nml" HK = "hk" class CmdInfo: OFF = "Off" ON = "On" NML = "Normal" HK = "HK" class Tmp1075ActionId(enum.IntEnum): GET_TEMP = 1 START_ADC_CONV = 2 class SetId(enum.IntEnum): TEMPERATURE = 1 def pack_tmp1075_test_into( object_id: ObjectIdU32, cmd_str: str, q: DefaultPusQueueHelper ): q.add_log_cmd( f"Testing Tmp1075 Temperature Sensor Handler with object id: {object_id}" ) obyt = object_id.as_bytes if cmd_str == CmdStr.OFF: q.add_log_cmd("TMP1075: Set Normal Off") mode_data = pack_mode_data(obyt, Mode.OFF, 0) q.add_pus_tc(PusTelecommand(service=200, subservice=1, app_data=mode_data)) if cmd_str == CmdStr.NML: q.add_log_cmd("TMP1075: Set Mode Normal") mode_data = pack_mode_data(obyt, Mode.NORMAL, 0) q.add_pus_tc(PusTelecommand(service=200, subservice=1, app_data=mode_data)) if cmd_str == CmdStr.ON: q.add_log_cmd("TMP1075: Set Mode On") mode_data = pack_mode_data(obyt, Mode.ON, 0) q.add_pus_tc(PusTelecommand(service=200, subservice=1, app_data=mode_data)) if cmd_str == CmdStr.HK: q.add_log_cmd("TMP1075: Request One-Shot HK") q.add_pus_tc(create_request_one_hk_command(make_sid(obyt, SetId.TEMPERATURE))) return q def create_tmp_sens_node() -> CmdTreeNode: node = CmdTreeNode("tmp_1075", "TMP1075 Temperatur Sensors") node.add_child(CmdTreeNode(CmdStr.OFF, CmdInfo.OFF)) node.add_child(CmdTreeNode(CmdStr.ON, CmdInfo.ON)) node.add_child(CmdTreeNode(CmdStr.NML, CmdInfo.NML)) node.add_child(CmdTreeNode(CmdStr.HK, CmdInfo.HK)) return node @tmtc_definitions_provider def add_tmp_sens_cmds(defs: TmtcDefinitionWrapper): oce = OpCodeEntry() oce.add(CmdStr.OFF, CmdInfo.OFF) oce.add(CmdStr.ON, CmdInfo.ON) oce.add(CmdStr.NML, CmdInfo.NML) oce.add(CmdStr.HK, CmdInfo.HK) defs.add_service(CustomServiceList.TMP1075.value, "TMP1075 Temperature Sensor", oce) def handle_tmp_1075_hk_data(set_id: int, hk_data: bytes, pw: PrintWrapper): if set_id == SetId.TEMPERATURE: temp = struct.unpack("!f", hk_data[0:4])[0] pw.dlog(f"TMP1075 Temperature: {temp}") pw.dlog(FsfwTmTcPrinter.get_validity_buffer(hk_data[4:], 1))