# -*- coding: utf-8 -*- """ @file tmtcc_tc_heater.py @brief Command sequence to test the HeaterHandler @author J. Meier @date 30.01.2021 """ from tmtccmd.core.definitions import QueueCommands from tmtccmd.pus_tc.packer import TcQueueT from tmtccmd.pus_tc.base import PusTelecommand class SwitchNumbers: HEATER_0 = 0 HEATER_1 = 1 HEATER_2 = 2 HEATER_3 = 3 HEATER_4 = 4 HEATER_5 = 5 HEATER_6 = 6 HEATER_7 = 7 NUMBER_OF_SWITCHES = 8 class ActionIds: SWITCH_HEATER = bytearray([0x0, 0x0, 0x0, 0x0]) def pack_heater_test_into(object_id: bytearray, tc_queue: TcQueueT): tc_queue.appendleft((QueueCommands.PRINT, "Testing Heater Switching")) heater_number = int(input("Type number of heater to switch: ")) if heater_number >= SwitchNumbers.NUMBER_OF_SWITCHES: print("Invalid heater switch number") return action = int(input("Turn switch on or off? (0 - off, 1 - on): ")) if action != 0 and action != 1: print("Invalid action defined. Must be 0 (off) or 1 (on") debug_string = "Switching heater " + str(heater_number) tc_queue.appendleft((QueueCommands.PRINT, debug_string)) command = pack_switch_heater_command(object_id, heater_number, action) command = PusTelecommand(service=8, subservice=128, ssc=300, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) def pack_switch_heater_command(object_id: bytearray, switch_nr: int, switch_action: int) -> bytearray: """ Function to generate the command switch a heater @param object_id The object id of the HeaterHandler object. @param switch_nr The switch number identifying the heater to switch @param switch_action Action to perform. 0 - Sets switch off, 1 - Sets switch on. """ action_id = ActionIds.SWITCH_HEATER command = object_id + action_id command.append(switch_nr) command.append(switch_action) return command