# -*- coding: utf-8 -*- """ @file tmtcc_tc_acu.py @brief ACU tests @author J. Meier @date 21.12.2020 """ from tmtccmd.pus_tc.packer import TcQueueT from tmtccmd.pus_tc.base import PusTelecommand from tmtccmd.core.definitions import QueueCommands from gomspace.gomspace_common import * from pus_tc.p60dock import P60DockConfigTable from config.object_ids import ObjIdIds from tmtccmd.core.object_id_manager import get_object_id class ACUTestProcedure: """ @brief Use this class to define the tests to perform for the ACU. @details Setting all to True will run all tests. Setting all to False will only run the tests set to True. """ all = False reboot = False read_gnd_wdt = False gnd_wdt_reset = False ping = False read_temperature1 = False read_temperature2 = False read_temperature3 = True read_mppt_mode = True read_vboost = True read_vbat_max_hi = True read_vbat_max_lo = True read_ov_mode = True class ACUConfigTable: mppt_mode = TableEntry(bytearray([0x00, 0x00]), TableEntry.uint8_size) mppt_d_mode = TableEntry(bytearray([0x00, 0x01]), TableEntry.uint8_size) vboost = TableEntry(bytearray([0x00, 0x02]), TableEntry.uint16_size) vbat_max_hi = TableEntry(bytearray([0x00, 0x10]), TableEntry.uint16_size) vbat_max_lo = TableEntry(bytearray([0x00, 0x12]), TableEntry.uint16_size) ov_mode = TableEntry(bytearray([0x00, 0x1A]), TableEntry.uint8_size) class ACUHkTable: temperature1 = TableEntry(bytearray([0x00, 0x1C]), TableEntry.uint16_size) temperature2 = TableEntry(bytearray([0x00, 0x1D]), TableEntry.uint16_size) temperature3 = TableEntry(bytearray([0x00, 0x1E]), TableEntry.uint16_size) # Ground WDT value (remaining seconds until reboot) wdt_gnd_left = TableEntry(bytearray([0x00, 0x74]), TableEntry.uint32_size) def pack_acu_test_into(object_id: bytearray, tc_queue: TcQueueT) -> TcQueueT: tc_queue.appendleft((QueueCommands.PRINT, "Testing ACU")) tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Enabling ACU connected to X1 slot (channel 0)")) p60dock_object_id = get_object_id(ObjIdIds.P60DOCK_HANDLER_ID) command = pack_set_param_command(p60dock_object_id, P60DockConfigTable.out_en_0.parameter_address, P60DockConfigTable.out_en_0.parameter_size, Channel.on) command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.reboot: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Reboot")) command = pack_reboot_command(object_id) command = PusTelecommand(service=8, subservice=128, ssc=22, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.read_gnd_wdt: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Reading ground watchdog timer value")) command = pack_get_param_command(object_id, TableIds.hk, ACUHkTable.wdt_gnd_left.parameter_address, ACUHkTable.wdt_gnd_left.parameter_size) command = PusTelecommand(service=8, subservice=128, ssc=20, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.gnd_wdt_reset: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Testing ground watchdog reset")) command = pack_gnd_wdt_reset_command(object_id) command = PusTelecommand(service=8, subservice=128, ssc=21, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.ping: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Ping Test")) ping_data = bytearray([0, 1, 2, 3, 4, 5, 6, 7, 8, 9]) command = pack_ping_command(object_id, ping_data) command = PusTelecommand(service=8, subservice=128, ssc=22, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.read_temperature3: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Reading temperature 3")) command = pack_get_param_command(object_id, TableIds.hk, ACUHkTable.temperature3.parameter_address, ACUHkTable.temperature3.parameter_size) command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.read_vboost: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Reading vboost value")) command = pack_get_param_command(object_id, TableIds.config, ACUConfigTable.vboost.parameter_address, ACUConfigTable.vboost.parameter_size) command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.read_vbat_max_hi: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Reading vbat_max_hi")) command = pack_get_param_command(object_id, TableIds.config, ACUConfigTable.vbat_max_hi.parameter_address, ACUConfigTable.vbat_max_hi.parameter_size) command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.read_vbat_max_lo: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Reading vbat_max_lo")) command = pack_get_param_command(object_id, TableIds.config, ACUConfigTable.vbat_max_lo.parameter_address, ACUConfigTable.vbat_max_lo.parameter_size) command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) if ACUTestProcedure.all or ACUTestProcedure.read_ov_mode: tc_queue.appendleft((QueueCommands.PRINT, "ACU: Reading ov_mode")) command = pack_get_param_command(object_id, TableIds.config, ACUConfigTable.ov_mode.parameter_address, ACUConfigTable.ov_mode.parameter_size) command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Turning off ACU")) command = pack_set_param_command(p60dock_object_id, P60DockConfigTable.out_en_0.parameter_address, P60DockConfigTable.out_en_0.parameter_size, Channel.off) command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command) tc_queue.appendleft(command.pack_command_tuple()) return tc_queue