# -*- coding: utf-8 -*- """ACU commands @author J. Meier, R. Mueller @date 21.12.2020 """ from config.definitions import CustomServiceList from tmtc.power.common_power import ( pack_gomspace_cmds, add_gomspace_cmd_defs, req_hk_cmds, ) from tmtccmd.config import TmtcDefinitionWrapper, OpCodeEntry from tmtccmd.config.tmtc import tmtc_definitions_provider from tmtccmd.tc import DefaultPusQueueHelper from tmtccmd.tc.pus_3_fsfw_hk import ( make_sid, generate_one_diag_command, generate_one_hk_command, ) import gomspace.gomspace_common as gs from gomspace.gomspace_common import GomspaceOpCodes from gomspace.gomspace_common import GsInfo as GsInfo from config.object_ids import ACU_HANDLER_ID from tmtc.power.p60dock import P60DockConfigTable from tmtccmd.tc.pus_8_funccmd import make_fsfw_action_cmd from tmtccmd.util import ObjectIdU32 class ACUConfigTable: mppt_mode = gs.TableEntry(bytearray([0x00, 0x00]), gs.TableEntry.uint8_size) mppt_d_mode = gs.TableEntry(bytearray([0x00, 0x01]), gs.TableEntry.uint8_size) vboost = gs.TableEntry(bytearray([0x00, 0x02]), gs.TableEntry.uint16_size) vbat_max_hi = gs.TableEntry(bytearray([0x00, 0x10]), gs.TableEntry.uint16_size) vbat_max_lo = gs.TableEntry(bytearray([0x00, 0x12]), gs.TableEntry.uint16_size) ov_mode = gs.TableEntry(bytearray([0x00, 0x1A]), gs.TableEntry.uint8_size) class ACUHkTable: temperature1 = gs.TableEntry(bytearray([0x00, 0x1C]), gs.TableEntry.uint16_size) temperature2 = gs.TableEntry(bytearray([0x00, 0x1D]), gs.TableEntry.uint16_size) temperature3 = gs.TableEntry(bytearray([0x00, 0x1E]), gs.TableEntry.uint16_size) # Ground WDT value (remaining seconds until reboot) wdt_gnd_left = gs.TableEntry(bytearray([0x00, 0x74]), gs.TableEntry.uint32_size) class OpCodes: TEST = ["0", "test"] class Info: TEST = "ACU Test" @tmtc_definitions_provider def add_acu_cmds(defs: TmtcDefinitionWrapper): oce = OpCodeEntry() add_gomspace_cmd_defs(oce) oce.add(keys=OpCodes.TEST, info=Info.TEST) defs.add_service( name=CustomServiceList.ACU.value, info="ACU Device", op_code_entry=oce, ) def pack_acu_commands(object_id: ObjectIdU32, q: DefaultPusQueueHelper, op_code: str): q.add_log_cmd("Handling ACU command") pack_gomspace_cmds("ACU", object_id, q, op_code) acu_req_hk_cmds(q, op_code) pack_test_cmds(object_id=object_id, q=q) def acu_req_hk_cmds(q: DefaultPusQueueHelper, op_code: str): req_hk_cmds( "ACU", q, op_code, ACU_HANDLER_ID, [gs.SetIds.ACU_CORE, gs.SetIds.ACU_AUX] ) class ACUTestProcedure: """ @brief Use this class to define the tests to perform for the ACU. @details Setting all to True will run all tests. Setting all to False will only run the tests set to True. """ all = False reboot = False read_gnd_wdt = False gnd_wdt_reset = False ping = False read_temperature1 = False read_temperature2 = False read_temperature3 = False read_mppt_mode = False read_vboost = False read_vbat_max_hi = False read_vbat_max_lo = False read_ov_mode = False off = False def pack_test_cmds(object_id: ObjectIdU32, q: DefaultPusQueueHelper): if ACUTestProcedure.all or ACUTestProcedure.reboot: q.add_log_cmd("ACU: Reboot") q.add_pus_tc(gs.pack_reboot_command(object_id)) if ACUTestProcedure.all or ACUTestProcedure.read_gnd_wdt: q.add_log_cmd("ACU: Reading ground watchdog timer value") q.add_pus_tc( gs.pack_get_param_command( object_id.as_bytes, gs.TableIds.hk, ACUHkTable.wdt_gnd_left.parameter_address, ACUHkTable.wdt_gnd_left.parameter_size, ) ) if ACUTestProcedure.all or ACUTestProcedure.gnd_wdt_reset: q.add_log_cmd("ACU: Testing ground watchdog reset") q.add_pus_tc(gs.pack_gnd_wdt_reset_command(object_id)) if ACUTestProcedure.all or ACUTestProcedure.ping: q.add_log_cmd("ACU: Ping Test") ping_data = bytearray([0, 1, 2, 3, 4, 5, 6, 7, 8, 9]) q.add_pus_tc(gs.pack_ping_command(object_id, ping_data)) if ACUTestProcedure.all or ACUTestProcedure.read_temperature3: q.add_log_cmd("ACU: Reading temperature 3") q.add_pus_tc( gs.pack_get_param_command( object_id.as_bytes, gs.TableIds.hk, ACUHkTable.temperature3.parameter_address, ACUHkTable.temperature3.parameter_size, ) ) if ACUTestProcedure.all or ACUTestProcedure.read_vboost: q.add_log_cmd("ACU: Reading vboost value") q.add_pus_tc( gs.pack_get_param_command( object_id.as_bytes, gs.TableIds.config, ACUConfigTable.vboost.parameter_address, ACUConfigTable.vboost.parameter_size, ) ) if ACUTestProcedure.all or ACUTestProcedure.read_vbat_max_hi: q.add_log_cmd("ACU: Reading vbat_max_hi") q.add_pus_tc( gs.pack_get_param_command( object_id.as_bytes, gs.TableIds.config, ACUConfigTable.vbat_max_hi.parameter_address, ACUConfigTable.vbat_max_hi.parameter_size, ) ) if ACUTestProcedure.all or ACUTestProcedure.read_vbat_max_lo: q.add_log_cmd("ACU: Reading vbat_max_lo") q.add_pus_tc( gs.pack_get_param_command( object_id.as_bytes, gs.TableIds.config, ACUConfigTable.vbat_max_lo.parameter_address, ACUConfigTable.vbat_max_lo.parameter_size, ) ) if ACUTestProcedure.all or ACUTestProcedure.read_ov_mode: q.add_log_cmd("ACU: Reading ov_mode") q.add_pus_tc( gs.pack_get_param_command( object_id.as_bytes, gs.TableIds.config, ACUConfigTable.ov_mode.parameter_address, ACUConfigTable.ov_mode.parameter_size, ) ) if ACUTestProcedure.all or ACUTestProcedure.off: q.add_log_cmd("P60 Dock: Turning off ACU") q.add_pus_tc( gs.pack_set_param_command( ACU_HANDLER_ID, P60DockConfigTable.out_en_0.parameter_address, P60DockConfigTable.out_en_0.parameter_size, gs.Channel.off, ) )