eive-tmtc/eive_tmtc/tmtc/power/pdu1.py

238 lines
7.9 KiB
Python

# -*- coding: utf-8 -*-
"""PDU1 is mounted on the X2 slot of the P60 dock
@author J. Meier
@date 17.12.2020
"""
from eive_tmtc.config.definitions import CustomServiceList
from eive_tmtc.config.object_ids import PDU_1_HANDLER_ID
from eive_tmtc.tmtc.power.common_power import (
pack_common_gomspace_cmds,
req_hk_cmds,
PowerOpCodes,
generic_on_cmd,
generic_off_cmd,
add_gomspace_cmd_defs,
pack_common_power_cmds,
GomspaceOpCodes,
GsInfo,
PowerInfo,
add_common_power_defs,
SetIds,
)
from eive_tmtc.gomspace.gomspace_common import *
from eive_tmtc.gomspace.gomspace_pdu_definitions import *
from tmtccmd.config import OpCodeEntry, TmtcDefinitionWrapper
from tmtccmd.config.tmtc import tmtc_definitions_provider
class Pdu1InfoBase:
TCS = "Switch TCS Board"
SYRLINKS = "Switch Syrlinks (COM)"
STR = "Switch Startracker"
MGT = "Switch Magnetorquer"
SUS_N = "Switch Sun Sensor Board Nominal"
SCEX = "Switch Solar Cell Experiment"
PLOC = "Switch Payload On-Board Computer"
ACS_A = "Switch ACS Board A-Side"
class Pdu1ChIndex(enum.IntEnum):
TCS = 0
SYRLINKS = 1
STR = 2
MGT = 3
SUS_N = 4
SCEX = 5
PLOC = 6
ACS_A = 7
class PDU1TestProcedure:
"""
@brief Use this class to define the tests to perform for the PDU2.
@details Setting all to True will run all tests.
Setting all to False will only run the tests set to True.
"""
all = False
reboot = False
ping = False
read_temperature = False
turn_channel_2_on = False # Star Tracker connected to this channel (5V)
turn_channel_2_off = False
turn_channel_3_on = False # MTQ connected to this channel (5V)
turn_channel_3_off = False
def pack_pdu1_commands(object_id: ObjectIdU32, q: DefaultPusQueueHelper, op_code: str):
q.add_log_cmd("Commanding PDU1")
objb = object_id.as_bytes
pdu1_switch_cmds(q, op_code)
pdu1_req_hk_cmds(q, op_code)
pack_common_power_cmds("PDU1", object_id, q, op_code)
pack_common_gomspace_cmds("PDU1", object_id, q, op_code)
if PDU1TestProcedure.all or PDU1TestProcedure.ping:
q.add_log_cmd("PDU1: Ping Test")
ping_data = bytearray([0, 1, 2, 3, 4, 5, 6, 7, 8, 9])
q.add_pus_tc(pack_ping_command(object_id, ping_data))
if PDU1TestProcedure.all or PDU1TestProcedure.read_temperature:
q.add_log_cmd("PDU1: Testing temperature reading")
q.add_pus_tc(
pack_get_param_command(
objb,
TableIds.HK,
PduHkTable.temperature.parameter_address,
PduHkTable.temperature.parameter_size,
)
)
def pdu1_req_hk_cmds(q: DefaultPusQueueHelper, op_code: str):
req_hk_cmds("PDU1", q, op_code, PDU_1_HANDLER_ID, [SetIds.CORE, SetIds.AUX])
def info_on_pdu1(base: str) -> str:
return "PDU1: " + base + " on"
def info_off_pdu1(base: str) -> str:
return "PDU1: " + base + " off"
def pdu1_switch_cmds(q: DefaultPusQueueHelper, op_code: str):
if op_code in PowerOpCodes.TCS_ON:
tcs_on_cmd(q)
elif op_code in PowerOpCodes.TCS_OFF:
tcs_off_cmd(q)
elif op_code in PowerOpCodes.SYRLINKS_ON:
syrlinks_on_cmd(q)
elif op_code in PowerOpCodes.SYRLINKS_OFF:
syrlinks_off_cmd(q)
elif op_code in PowerOpCodes.STAR_TRACKER_ON:
startracker_on_cmd(q)
elif op_code in PowerOpCodes.STAR_TRACKER_OFF:
startracker_off_cmd(q)
elif op_code in PowerOpCodes.MGT_ON:
mgt_on_cmd(q)
elif op_code in PowerOpCodes.MGT_OFF:
mgt_off_cmd(q)
elif op_code in PowerOpCodes.SUS_N_ON:
sun_sensor_nominal_on_cmd(q)
elif op_code in PowerOpCodes.SUS_N_OFF:
sun_sensor_nominal_off_cmd(q)
elif op_code in PowerOpCodes.SCEX_ON:
solar_cell_experiment_on_cmd(q)
elif op_code in PowerOpCodes.SCEX_OFF:
solar_cell_experiment_off_cmd(q)
elif op_code in PowerOpCodes.PLOC_ON:
ploc_on_cmd(q)
elif op_code in PowerOpCodes.PLOC_OFF:
ploc_off_cmd(q)
elif op_code in PowerOpCodes.ACS_A_ON:
acs_board_a_on_cmd(q)
elif op_code in PowerOpCodes.ACS_A_OFF:
acs_board_a_off_cmd(q)
def add_pdu1_common_defs(oce: OpCodeEntry):
oce.add(keys=PowerOpCodes.TCS_ON, info=info_on_pdu1(Pdu1InfoBase.TCS))
oce.add(keys=PowerOpCodes.TCS_OFF, info=info_off_pdu1(Pdu1InfoBase.TCS))
oce.add(keys=PowerOpCodes.STAR_TRACKER_ON, info=info_on_pdu1(Pdu1InfoBase.STR))
oce.add(keys=PowerOpCodes.STAR_TRACKER_OFF, info=info_off_pdu1(Pdu1InfoBase.STR))
oce.add(keys=PowerOpCodes.SUS_N_ON, info=info_on_pdu1(Pdu1InfoBase.SUS_N))
oce.add(keys=PowerOpCodes.SUS_N_OFF, info=info_off_pdu1(Pdu1InfoBase.SUS_N))
oce.add(keys=PowerOpCodes.ACS_A_ON, info=info_on_pdu1(Pdu1InfoBase.ACS_A))
oce.add(keys=PowerOpCodes.ACS_A_OFF, info=info_off_pdu1(Pdu1InfoBase.ACS_A))
oce.add(keys=PowerOpCodes.SYRLINKS_ON, info=info_on_pdu1(Pdu1InfoBase.SYRLINKS))
oce.add(keys=PowerOpCodes.SYRLINKS_OFF, info=info_off_pdu1(Pdu1InfoBase.SYRLINKS))
oce.add(keys=PowerOpCodes.MGT_ON, info=info_on_pdu1(Pdu1InfoBase.MGT))
oce.add(keys=PowerOpCodes.MGT_OFF, info=info_off_pdu1(Pdu1InfoBase.MGT))
oce.add(keys=PowerOpCodes.PLOC_ON, info=info_on_pdu1(Pdu1InfoBase.PLOC))
oce.add(keys=PowerOpCodes.PLOC_OFF, info=info_off_pdu1(Pdu1InfoBase.PLOC))
oce.add(keys=PowerOpCodes.SCEX_ON, info=info_on_pdu1(Pdu1InfoBase.SCEX))
oce.add(keys=PowerOpCodes.SCEX_OFF, info=info_off_pdu1(Pdu1InfoBase.SCEX))
@tmtc_definitions_provider
def add_pdu1_cmds(defs: TmtcDefinitionWrapper):
oce = OpCodeEntry()
add_pdu1_common_defs(oce)
add_common_power_defs(oce)
add_gomspace_cmd_defs(oce)
oce.add(
keys=PowerOpCodes.PRINT_SWITCH_V_I,
info="PDU1: Print Switches, Voltages, Currents",
)
oce.add(keys=GomspaceOpCodes.GET_PARAM, info=GsInfo.GET_PARAMETER)
defs.add_service(
name=CustomServiceList.PDU1.value,
info="PDU1 Device",
op_code_entry=oce,
)
def tcs_on_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.TCS, Pdu1ChIndex.TCS)
def tcs_off_cmd(q: DefaultPusQueueHelper):
generic_off_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.TCS, Pdu1ChIndex.TCS)
def syrlinks_on_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.SYRLINKS, Pdu1ChIndex.SYRLINKS)
def syrlinks_off_cmd(q: DefaultPusQueueHelper):
generic_off_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.SYRLINKS, Pdu1ChIndex.SYRLINKS)
def startracker_on_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.STR, Pdu1ChIndex.STR)
def startracker_off_cmd(q: DefaultPusQueueHelper):
generic_off_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.STR, Pdu1ChIndex.STR)
def mgt_on_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.MGT, Pdu1ChIndex.MGT)
def mgt_off_cmd(q: DefaultPusQueueHelper):
generic_off_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.MGT, Pdu1ChIndex.MGT)
def sun_sensor_nominal_on_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.SUS_N, Pdu1ChIndex.SUS_N)
def sun_sensor_nominal_off_cmd(q: DefaultPusQueueHelper):
generic_off_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.SUS_N, Pdu1ChIndex.SUS_N)
def solar_cell_experiment_on_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.SCEX, Pdu1ChIndex.SCEX)
def solar_cell_experiment_off_cmd(q: DefaultPusQueueHelper):
generic_off_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.SCEX, Pdu1ChIndex.SCEX)
def ploc_on_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.PLOC, Pdu1ChIndex.PLOC)
def ploc_off_cmd(q: DefaultPusQueueHelper):
generic_off_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.PLOC, Pdu1ChIndex.PLOC)
def acs_board_a_on_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.ACS_A, Pdu1ChIndex.ACS_A)
def acs_board_a_off_cmd(q: DefaultPusQueueHelper):
generic_on_cmd(PDU_1_HANDLER_ID, q, Pdu1InfoBase.ACS_A, Pdu1ChIndex.ACS_A)