173 lines
5.4 KiB
Python
173 lines
5.4 KiB
Python
from datetime import timedelta
|
|
|
|
from spacepackets.ecss.tc import PusTelecommand
|
|
|
|
from deps.spacepackets.spacepackets.ecss import PusServices
|
|
from tmtccmd.config import TmtcDefinitionWrapper, OpCodeEntry
|
|
from tmtccmd.tc.pus_200_fsfw_modes import pack_mode_data, Modes
|
|
from tmtccmd.tc.pus_20_params import (
|
|
pack_boolean_parameter_app_data,
|
|
pack_fsfw_load_param_cmd,
|
|
)
|
|
from tmtccmd.tc.pus_3_fsfw_hk import make_sid, generate_one_hk_command
|
|
import tmtccmd.tc.pus_3_fsfw_hk as srv3
|
|
from tmtccmd.tc.pus_8_funccmd import generate_action_command
|
|
|
|
from common_tmtc.config.object_ids import TEST_DEVICE_0_ID, TEST_DEVICE_1_ID
|
|
|
|
|
|
# Set IDs
|
|
from tmtccmd.tc.queue import DefaultPusQueueHelper
|
|
|
|
TEST_SET_ID = 0
|
|
|
|
# Action IDs
|
|
TEST_NOTIFICATION_ACTION_ID = 3
|
|
|
|
# Parameters
|
|
PARAM_ACTIVATE_CHANGING_DATASETS = 4
|
|
|
|
|
|
def add_hk_cmds(defs: TmtcDefinitionWrapper):
|
|
op_code_entry = OpCodeEntry()
|
|
op_code_entry.add(keys=["0", "test"], info="Generic Test")
|
|
defs.add_service(
|
|
name=str(PusServices.S3_HOUSEKEEPING.value),
|
|
info="PUS Service 3 Housekeeping",
|
|
op_code_entry=op_code_entry,
|
|
)
|
|
|
|
|
|
def pack_service_3_commands_into(q: DefaultPusQueueHelper, op_code: str):
|
|
current_ssc = 3000
|
|
device_idx = 0
|
|
if device_idx == 0:
|
|
object_id = TEST_DEVICE_0_ID
|
|
else:
|
|
object_id = TEST_DEVICE_1_ID
|
|
|
|
if op_code == "0":
|
|
# This will pack all the tests
|
|
pack_service_3_test_info(
|
|
q=q,
|
|
object_id=object_id,
|
|
device_idx=device_idx,
|
|
)
|
|
elif op_code == "1":
|
|
# Extremely simple, generate one HK packet
|
|
pack_gen_one_hk_command(
|
|
q=q,
|
|
device_idx=device_idx,
|
|
object_id=object_id,
|
|
)
|
|
elif op_code == "2":
|
|
# Housekeeping basic test
|
|
pack_housekeeping_basic_test(q=q, object_id=object_id)
|
|
elif op_code == "3":
|
|
# Notification demo
|
|
pack_notification_basic_test(q=q, object_id=object_id)
|
|
|
|
|
|
def pack_service_3_test_info(
|
|
q: DefaultPusQueueHelper, device_idx: int, object_id: bytearray
|
|
):
|
|
q.add_log_cmd("Service 3 (Housekeeping Service): All tests")
|
|
pack_gen_one_hk_command(q=q, device_idx=device_idx, object_id=object_id)
|
|
pack_housekeeping_basic_test(q=q, object_id=object_id)
|
|
pack_notification_basic_test(
|
|
q=q,
|
|
object_id=object_id,
|
|
enable_normal_mode=False,
|
|
)
|
|
|
|
|
|
def pack_gen_one_hk_command(
|
|
q: DefaultPusQueueHelper, device_idx: int, object_id: bytearray
|
|
):
|
|
test_sid = make_sid(object_id=object_id, set_id=TEST_SET_ID)
|
|
q.add_log_cmd(
|
|
f"Service 3 Test: Generate one test set packet for test device {device_idx}"
|
|
)
|
|
q.add_pus_tc(generate_one_hk_command(sid=test_sid))
|
|
|
|
|
|
def pack_housekeeping_basic_test(
|
|
q: DefaultPusQueueHelper,
|
|
object_id: bytearray,
|
|
enable_normal_mode: bool = True,
|
|
):
|
|
"""
|
|
This basic test will request one HK packet, then it will enable periodic packets and listen
|
|
to the periodic packets for a few seconds. After that, HK packets will be disabled again.
|
|
"""
|
|
test_sid = make_sid(object_id=object_id, set_id=TEST_SET_ID)
|
|
# Enable changing datasets via parameter service (Service 20)
|
|
q.add_log_cmd("Service 3 Test: Performing basic HK tests")
|
|
|
|
if enable_normal_mode:
|
|
# Set mode normal so that sets are changed/read regularly
|
|
q.add_log_cmd("Service 3 Test: Set Normal Mode")
|
|
mode_data = pack_mode_data(object_id, Modes.NORMAL, 0)
|
|
q.add_pus_tc(PusTelecommand(service=200, subservice=1, app_data=mode_data))
|
|
|
|
q.add_log_cmd("Enabling changing datasets")
|
|
app_data = pack_boolean_parameter_app_data(
|
|
object_id=object_id,
|
|
domain_id=0,
|
|
unique_id=PARAM_ACTIVATE_CHANGING_DATASETS,
|
|
parameter=True,
|
|
)
|
|
q.add_pus_tc(pack_fsfw_load_param_cmd(app_data=app_data))
|
|
|
|
# Enable periodic reporting
|
|
q.add_log_cmd("Enabling periodic thermal sensor packet generation: ")
|
|
q.add_pus_tc(
|
|
PusTelecommand(
|
|
service=3,
|
|
subservice=srv3.Subservices.TC_ENABLE_PERIODIC_HK_GEN,
|
|
app_data=test_sid,
|
|
)
|
|
)
|
|
q.add_wait(timedelta(seconds=2.0))
|
|
|
|
# Disable periodic reporting
|
|
q.add_log_cmd("Disabling periodic thermal sensor packet generation: ")
|
|
q.add_pus_tc(
|
|
PusTelecommand(
|
|
service=3,
|
|
subservice=srv3.Subservices.TC_DISABLE_PERIODIC_HK_GEN,
|
|
app_data=test_sid,
|
|
)
|
|
)
|
|
|
|
# Disable changing datasets via parameter service (Service 20)
|
|
q.add_log_cmd("Disabling changing datasets")
|
|
app_data = pack_boolean_parameter_app_data(
|
|
object_id=object_id,
|
|
domain_id=0,
|
|
unique_id=PARAM_ACTIVATE_CHANGING_DATASETS,
|
|
parameter=False,
|
|
)
|
|
q.add_pus_tc(pack_fsfw_load_param_cmd(app_data=app_data))
|
|
|
|
|
|
def pack_notification_basic_test(
|
|
q: DefaultPusQueueHelper,
|
|
object_id: bytearray,
|
|
enable_normal_mode: bool = True,
|
|
):
|
|
q.add_log_cmd("Service 3 Test: Performing notification tests")
|
|
|
|
if enable_normal_mode:
|
|
# Set mode normal so that sets are changed/read regularly
|
|
q.add_log_cmd("Service 3 Test: Set Normal Mode")
|
|
mode_data = pack_mode_data(object_id, Modes.NORMAL, 0)
|
|
q.add_pus_tc(PusTelecommand(service=200, subservice=1, app_data=mode_data))
|
|
|
|
q.add_log_cmd("Triggering notification")
|
|
q.add_pus_tc(
|
|
generate_action_command(
|
|
object_id=object_id, action_id=TEST_NOTIFICATION_ACTION_ID
|
|
)
|
|
)
|