# Tübingen Instruments RIU-9000 Datasheet --- ## Manufacturer: TI (Tübingen Instruments) ### Overview The RIU-9000 is a versatile Remote Interface Unit (RIU) designed for spacecraft sensor management. This device interfaces with an Adafruit BMP280 sensor to provide accurate pressure and temperature readings. The RIU-9000 allows users to configure sensor parameters and retrieve sensor data through a structured 4-step communication protocol. ### Features - **Sensor Support**: Integrated support for BMP280 pressure and temperature sensor. - **Configurable Parameters**: Offset and sampling rate adjustments for both pressure and temperature readings. - **Reliable Communication**: 4-step communication protocol to ensure data integrity. - **Error Handling**: Error messages for invalid commands or parameters. - **Industry Standard Data Format**: Sensor data is sent in binary format representing 32 bit IEEE-754 Floating Point values. --- ### Commands and Responses #### General Format Commands should be sent as strings over the serial interface at 115200 baud rate. Commands are case-sensitive and must be followed by a newline character (`\n`). Parameters and values should be separated by a space. Responses from the RIU-9000 will also be in string format. #### STARTUP - **Command**: `STARTUP` - **Response**: `READY - Tübingen Instruments RIU-9000` - **Description**: Initializes the device. This command must be sent before any other commands are accepted. #### GET_SENSOR - **Command**: `GET_SENSOR [COMMAND] [SENSOR]` - **Description**: Initiates a 4-step communication process to read sensor data. - **Steps**: 1. **REQUEST**: Command the device to read sensor value. - **Command**: `GET_SENSOR REQUEST [SENSOR]` - **Response**: `OK` or `ERROR` 2. **CONFIRM**: Ask if the device requested the data from the sensor. - **Command**: `GET_SENSOR CONFIRM [SENSOR]` - **Response**: `TRUE` or `FALSE` 3. **CHECK**: Ask if the data is present now. - **Command**: `GET_SENSOR CHECK [SENSOR]` - **Response**: `TRUE` or `FALSE` 4. **SEND**: Command the device to send the data to the user. - **Command**: `GET_SENSOR SEND [SENSOR]` - **Response**: `[DATA]` or `FALSE` 5. **CANCEL**: Cancel the sensor reading request. - **Command**: `GET_SENSOR CANCEL [SENSOR]` - **Response**: `OK` #### SET_PARAMETER - **Command**: `SET_PARAMETER [PARAM] [VALUE]` - **Response**: `OK` or `ERROR: UNKNOWN PARAMETER` - **Parameters**: - `PRESSURE_OFFSET`: Sets the offset for pressure readings. (In hPa) - `TEMPERATURE_OFFSET`: Sets the offset for temperature readings. (In °C) - `PRESSURE_SAMPLING`: Sets the oversampling rate for the pressure sensor (`SAMPLING_NONE`, `SAMPLING_X1`, `SAMPLING_X2`, `SAMPLING_X4`, `SAMPLING_X8`, `SAMPLING_X16`). - `TEMPERATURE_SAMPLING`: Sets the oversampling rate for the temperature sensor (`SAMPLING_NONE`, `SAMPLING_X1`, `SAMPLING_X2`, `SAMPLING_X4`, `SAMPLING_X8`, `SAMPLING_X16`). #### GET_PARAMETER - **Command**: `GET_PARAMETER [PARAM]` - **Response**: `[VALUE]` or `ERROR: UNKNOWN PARAMETER` - **Parameters**: - `PRESSURE_OFFSET`: Retrieves the current pressure offset. - `TEMPERATURE_OFFSET`: Retrieves the current temperature offset. - `PRESSURE_SAMPLING`: Retrieves the current pressure oversampling rate. - `TEMPERATURE_SAMPLING`: Retrieves the current temperature oversampling rate. #### RESET_SENSORS - **Command**: `RESET_SENSORS` - **Response**: `OK` - **Description**: Resets the request count and communication state. #### Communication Errors - **BUSY**: Device is busy. Every 20th request, the device will respond with `BUSY` and not process the command. - **ERROR**: Generic error message for invalid commands or failed operations. - **FALSE**: Response for confirmation checks that fail. - **[NO RESPONSE]**: After 100 requests, the device will stop responding to commands until a `RESET_SENSORS` command is issued. --- ### Example Usage #### Initialization ``` User: STARTUP Device: READY ``` #### Setting Parameters ``` User: SET_PARAMETER PRESSURE_OFFSET 10 Device: OK User: SET_PARAMETER PRESSURE_SAMPLING SAMPLING_X4 Device: OK ``` #### Getting Parameters ``` User: GET_PARAMETER PRESSURE_OFFSET Device: 10 User: GET_PARAMETER PRESSURE_SAMPLING Device: SAMPLING_X4 ``` #### Reading Sensor Data ``` User: GET_SENSOR REQUEST PRESSURE Device: OK User: GET_SENSOR CONFIRM PRESSURE Device: OK User: GET_SENSOR CHECK PRESSURE Device: FALSE User: GET_SENSOR CHECK PRESSURE Device: TRUE User: GET_SENSOR SEND PRESSURE Device: [Binary Data] ``` #### Resetting Sensors ``` User: RESET_SENSORS Device: OK ``` --- For more detailed information and troubleshooting, please refer to the official TI (Tübingen Instruments) RIU-9000 documentation. ---