2808;INVALID_DEVICE_COMMAND;LOW;Indicates a SW bug in child class.;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/fsfw/src/fsfw/devicehandlers/DeviceHandlerIF.h
7900;RF_AVAILABLE;INFO;A RF available signal was detected. P1: raw RFA state, P2: 0;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
7901;RF_LOST;INFO;A previously found RF available signal was lost. P1: raw RFA state, P2: 0;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
7902;BIT_LOCK;INFO;A Bit Lock signal. Was detected. P1: raw BLO state, P2: 0;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
7903;BIT_LOCK_LOST;INFO;A previously found Bit Lock signal was lost. P1: raw BLO state, P2: 0;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
7905;FRAME_PROCESSING_FAILED;LOW;The CCSDS Board could not interpret a TC;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
11201;SELF_TEST_I2C_FAILURE;LOW;Get self test result returns I2C failure P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/IMTQHandler.h
11202;SELF_TEST_SPI_FAILURE;LOW;Get self test result returns SPI failure. This concerns the MTM connectivity. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/IMTQHandler.h
11203;SELF_TEST_ADC_FAILURE;LOW;Get self test result returns failure in measurement of current and temperature. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/IMTQHandler.h
11204;SELF_TEST_PWM_FAILURE;LOW;Get self test result returns PWM failure which concerns the coil actuation. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/IMTQHandler.h
11205;SELF_TEST_TC_FAILURE;LOW;Get self test result returns TC failure (system failure) P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/IMTQHandler.h
11206;SELF_TEST_MTM_RANGE_FAILURE;LOW;Get self test result returns failure that MTM values were outside of the expected range. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/IMTQHandler.h
11207;SELF_TEST_COIL_CURRENT_FAILURE;LOW;Get self test result returns failure indicating that the coil current was outside of the expected range P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/IMTQHandler.h
11208;INVALID_ERROR_BYTE;LOW;Received invalid error byte. This indicates an error of the communication link between IMTQ and OBC.;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/IMTQHandler.h
11301;ERROR_STATE;HIGH;Reaction wheel signals an error state;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/mission/devices/RwHandler.h
11501;SUPV_MEMORY_READ_RPT_CRC_FAILURE;LOW;PLOC supervisor crc failure in telemetry packet;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/PlocSupervisorHandler.h
11502;SUPV_ACK_FAILURE;LOW;PLOC supervisor received acknowledgment failure report;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/PlocSupervisorHandler.h
11503;SUPV_EXE_FAILURE;LOW;PLOC received execution failure report;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/PlocSupervisorHandler.h
11504;SUPV_CRC_FAILURE_EVENT;LOW;PLOC supervisor reply has invalid crc;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/PlocSupervisorHandler.h
11702;UPDATE_AVAILABLE_FAILED;LOW;Supervisor handler replied action message indicating a command execution failure of the update available command;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/PlocUpdater.h
11703;UPDATE_TRANSFER_FAILED;LOW;Supervisor handler failed to transfer an update space packet. P1: Parameter holds the number of update packets already sent (inclusive the failed packet);C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/PlocUpdater.h
11704;UPDATE_VERIFY_FAILED;LOW;Supervisor failed to execute the update verify command.;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/PlocUpdater.h
12002;IMAGE_UPLOAD_SUCCESSFUL;LOW;Uploading image to star tracker was successful;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/startracker/StrHelper.h
12003;IMAGE_DOWNLOAD_SUCCESSFUL;LOW;Image download was successful;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/startracker/StrHelper.h
12010;STR_HELPER_NO_REPLY;LOW;Star tracker did not send replies (maybe device is powered off)P1: Position of upload or download packet for which no reply was sent;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/startracker/StrHelper.h
12011;INVALID_TYPE_ID;LOW;Received reply with invalid type ID;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/startracker/StrHelper.h
12012;STATUS_ERROR;LOW;Status field in reply signals error;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/startracker/StrHelper.h
12014;POSITION_MISMATCH;LOW;Position mismatch P1: The expected position and thus the position for which the image upload/download failed;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/startracker/StrHelper.h
12015;STR_HELPER_FILE_NOT_EXISTS;LOW;Specified file does not existP1: Internal state of str helper;C:\Users\jakob\OneDrive\Work\EIVE\Q7S\Software\eive_obsw/bsp_q7s/devices/startracker/StrHelper.h