2021-07-13 08:32:14 +02:00
|
|
|
#include "PlocSupervisorHandler.h"
|
|
|
|
#include "OBSWConfig.h"
|
|
|
|
|
|
|
|
#include <fsfw/globalfunctions/CRC.h>
|
|
|
|
#include <fsfw/datapool/PoolReadGuard.h>
|
|
|
|
#include <fsfw/timemanager/Clock.h>
|
|
|
|
|
2021-07-23 13:27:58 +02:00
|
|
|
PlocSupervisorHandler::PlocSupervisorHandler(object_id_t objectId, object_id_t uartComIFid, CookieIF * comCookie) :
|
2021-07-24 13:57:05 +02:00
|
|
|
DeviceHandlerBase(objectId, uartComIFid, comCookie), hkset(this), bootStatusReport(this) {
|
2021-07-13 08:32:14 +02:00
|
|
|
if (comCookie == NULL) {
|
|
|
|
sif::error << "PlocSupervisorHandler: Invalid com cookie" << std::endl;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
PlocSupervisorHandler::~PlocSupervisorHandler() {
|
|
|
|
}
|
|
|
|
|
2021-07-23 13:27:58 +02:00
|
|
|
ReturnValue_t PlocSupervisorHandler::initialize() {
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
result = DeviceHandlerBase::initialize();
|
|
|
|
if (result != RETURN_OK) {
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
uartComIf = dynamic_cast<UartComIF*>(communicationInterface);
|
|
|
|
if (uartComIf == nullptr) {
|
|
|
|
sif::warning << "PlocSupervisorHandler::initialize: Invalid uart com if" << std::endl;
|
|
|
|
return INVALID_UART_COM_IF;
|
|
|
|
}
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
2021-07-13 08:32:14 +02:00
|
|
|
|
|
|
|
void PlocSupervisorHandler::doStartUp(){
|
|
|
|
#if OBSW_SWITCH_TO_NORMAL_MODE_AFTER_STARTUP == 1
|
|
|
|
setMode(MODE_NORMAL);
|
|
|
|
#else
|
|
|
|
setMode(_MODE_TO_ON);
|
|
|
|
#endif
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::doShutDown(){
|
|
|
|
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::buildNormalDeviceCommand(
|
|
|
|
DeviceCommandId_t * id) {
|
|
|
|
return NOTHING_TO_SEND;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::buildTransitionDeviceCommand(
|
|
|
|
DeviceCommandId_t * id){
|
|
|
|
return NOTHING_TO_SEND;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::buildCommandFromCommand(
|
|
|
|
DeviceCommandId_t deviceCommand, const uint8_t * commandData,
|
|
|
|
size_t commandDataLen) {
|
2021-07-23 13:27:58 +02:00
|
|
|
ReturnValue_t result = RETURN_FAILED;
|
2021-07-13 08:32:14 +02:00
|
|
|
switch(deviceCommand) {
|
|
|
|
case(PLOC_SPV::GET_HK_REPORT): {
|
|
|
|
prepareEmptyCmd(PLOC_SPV::APID_GET_HK_REPORT);
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
|
|
|
case(PLOC_SPV::RESTART_MPSOC): {
|
|
|
|
prepareEmptyCmd(PLOC_SPV::APID_RESTART_MPSOC);
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
|
|
|
case(PLOC_SPV::START_MPSOC): {
|
|
|
|
prepareEmptyCmd(PLOC_SPV::APID_START_MPSOC);
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
|
|
|
case(PLOC_SPV::SHUTDOWN_MPSOC): {
|
|
|
|
prepareEmptyCmd(PLOC_SPV::APID_SHUTWOWN_MPSOC);
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
|
|
|
case(PLOC_SPV::SEL_MPSOC_BOOT_IMAGE): {
|
|
|
|
prepareSelBootImageCmd(commandData);
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
2021-07-22 08:06:04 +02:00
|
|
|
case(PLOC_SPV::RESET_MPSOC): {
|
|
|
|
prepareEmptyCmd(PLOC_SPV::APID_RESET_MPSOC);
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-22 08:06:04 +02:00
|
|
|
}
|
2021-07-13 08:32:14 +02:00
|
|
|
case(PLOC_SPV::SET_TIME_REF): {
|
2021-07-23 13:27:58 +02:00
|
|
|
result = prepareSetTimeRefCmd();
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
|
|
|
case(PLOC_SPV::SET_BOOT_TIMEOUT): {
|
|
|
|
prepareSetBootTimeoutCmd(commandData);
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-22 08:06:04 +02:00
|
|
|
}
|
|
|
|
case(PLOC_SPV::SET_MAX_RESTART_TRIES): {
|
|
|
|
prepareRestartTriesCmd(commandData);
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-22 08:06:04 +02:00
|
|
|
}
|
|
|
|
case(PLOC_SPV::DISABLE_PERIOIC_HK_TRANSMISSION): {
|
|
|
|
prepareDisableHk();
|
2021-07-23 13:27:58 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
2021-07-24 13:57:05 +02:00
|
|
|
case(PLOC_SPV::GET_BOOT_STATUS_REPORT): {
|
|
|
|
prepareEmptyCmd(PLOC_SPV::APID_GET_BOOT_STATUS_RPT);
|
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
2021-07-25 20:42:24 +02:00
|
|
|
}
|
|
|
|
case(PLOC_SPV::UPDATE_AVAILABLE): {
|
2021-07-26 12:08:38 +02:00
|
|
|
prepareUpdateAvailableCmd(commandData);
|
2021-07-25 20:42:24 +02:00
|
|
|
result = RETURN_OK;
|
|
|
|
break;
|
|
|
|
}
|
2021-07-13 08:32:14 +02:00
|
|
|
default:
|
|
|
|
sif::debug << "PlocSupervisorHandler::buildCommandFromCommand: Command not implemented"
|
|
|
|
<< std::endl;
|
2021-07-23 13:27:58 +02:00
|
|
|
result = DeviceHandlerIF::COMMAND_NOT_IMPLEMENTED;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (result == RETURN_OK) {
|
|
|
|
/**
|
|
|
|
* Flushing the receive buffer to make sure there are no data left from a faulty reply.
|
|
|
|
*/
|
|
|
|
uartComIf->flushUartRxBuffer(comCookie);
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
2021-07-23 13:27:58 +02:00
|
|
|
|
|
|
|
return result;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::fillCommandAndReplyMap() {
|
|
|
|
this->insertInCommandMap(PLOC_SPV::GET_HK_REPORT);
|
|
|
|
this->insertInCommandMap(PLOC_SPV::RESTART_MPSOC);
|
|
|
|
this->insertInCommandMap(PLOC_SPV::START_MPSOC);
|
|
|
|
this->insertInCommandMap(PLOC_SPV::SHUTDOWN_MPSOC);
|
|
|
|
this->insertInCommandMap(PLOC_SPV::SEL_MPSOC_BOOT_IMAGE);
|
|
|
|
this->insertInCommandMap(PLOC_SPV::SET_BOOT_TIMEOUT);
|
|
|
|
this->insertInCommandMap(PLOC_SPV::SET_MAX_RESTART_TRIES);
|
|
|
|
this->insertInCommandMap(PLOC_SPV::RESET_MPSOC);
|
|
|
|
this->insertInCommandMap(PLOC_SPV::SET_TIME_REF);
|
2021-07-22 08:06:04 +02:00
|
|
|
this->insertInCommandMap(PLOC_SPV::DISABLE_PERIOIC_HK_TRANSMISSION);
|
2021-07-24 13:57:05 +02:00
|
|
|
this->insertInCommandMap(PLOC_SPV::GET_BOOT_STATUS_REPORT);
|
2021-07-13 08:32:14 +02:00
|
|
|
this->insertInReplyMap(PLOC_SPV::ACK_REPORT, 3, nullptr, PLOC_SPV::SIZE_ACK_REPORT);
|
|
|
|
this->insertInReplyMap(PLOC_SPV::EXE_REPORT, 3, nullptr, PLOC_SPV::SIZE_EXE_REPORT);
|
2021-07-25 20:42:24 +02:00
|
|
|
this->insertInReplyMap(PLOC_SPV::HK_REPORT, 3, &hkset, PLOC_SPV::SIZE_HK_REPORT);
|
2021-07-26 12:08:38 +02:00
|
|
|
this->insertInReplyMap(PLOC_SPV::BOOT_STATUS_REPORT, 3, &bootStatusReport,
|
2021-07-25 20:42:24 +02:00
|
|
|
PLOC_SPV::SIZE_BOOT_STATUS_REPORT);
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::scanForReply(const uint8_t *start,
|
|
|
|
size_t remainingSize, DeviceCommandId_t *foundId, size_t *foundLen) {
|
|
|
|
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
|
|
|
|
uint16_t apid = (*(start) << 8 | *(start + 1)) & APID_MASK;
|
|
|
|
|
|
|
|
switch(apid) {
|
|
|
|
case(PLOC_SPV::APID_ACK_SUCCESS):
|
|
|
|
*foundLen = PLOC_SPV::SIZE_ACK_REPORT;
|
|
|
|
*foundId = PLOC_SPV::ACK_REPORT;
|
|
|
|
break;
|
|
|
|
case(PLOC_SPV::APID_ACK_FAILURE):
|
|
|
|
*foundLen = PLOC_SPV::SIZE_ACK_REPORT;
|
|
|
|
*foundId = PLOC_SPV::ACK_REPORT;
|
|
|
|
break;
|
|
|
|
case(PLOC_SPV::APID_HK_REPORT):
|
|
|
|
*foundLen = PLOC_SPV::SIZE_HK_REPORT;
|
|
|
|
*foundId = PLOC_SPV::HK_REPORT;
|
|
|
|
break;
|
2021-07-26 12:08:38 +02:00
|
|
|
case(PLOC_SPV::APID_BOOT_STATUS_REPORT):
|
|
|
|
*foundLen = PLOC_SPV::SIZE_BOOT_STATUS_REPORT;
|
|
|
|
*foundId = PLOC_SPV::BOOT_STATUS_REPORT;
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
case(PLOC_SPV::APID_EXE_SUCCESS):
|
|
|
|
*foundLen = PLOC_SPV::SIZE_EXE_REPORT;
|
|
|
|
*foundId = PLOC_SPV::EXE_REPORT;
|
|
|
|
break;
|
|
|
|
case(PLOC_SPV::APID_EXE_FAILURE):
|
|
|
|
*foundLen = PLOC_SPV::SIZE_EXE_REPORT;
|
|
|
|
*foundId = PLOC_SPV::EXE_REPORT;
|
|
|
|
break;
|
|
|
|
default: {
|
|
|
|
sif::debug << "PlocSupervisorHandler::scanForReply: Reply has invalid apid" << std::endl;
|
|
|
|
*foundLen = remainingSize;
|
|
|
|
return INVALID_APID;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::interpretDeviceReply(DeviceCommandId_t id,
|
|
|
|
const uint8_t *packet) {
|
|
|
|
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
|
|
|
|
switch (id) {
|
|
|
|
case PLOC_SPV::ACK_REPORT: {
|
|
|
|
result = handleAckReport(packet);
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
case (PLOC_SPV::HK_REPORT): {
|
|
|
|
result = handleHkReport(packet);
|
|
|
|
break;
|
|
|
|
}
|
2021-07-24 13:57:05 +02:00
|
|
|
case (PLOC_SPV::BOOT_STATUS_REPORT): {
|
|
|
|
result = handleBootStatusReport(packet);
|
|
|
|
break;
|
|
|
|
}
|
2021-07-13 08:32:14 +02:00
|
|
|
case (PLOC_SPV::EXE_REPORT): {
|
|
|
|
result = handleExecutionReport(packet);
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
default: {
|
|
|
|
sif::debug << "PlocSupervisorHandler::interpretDeviceReply: Unknown device reply id" << std::endl;
|
|
|
|
return DeviceHandlerIF::UNKNOWN_DEVICE_REPLY;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::setNormalDatapoolEntriesInvalid(){
|
|
|
|
|
|
|
|
}
|
|
|
|
|
|
|
|
uint32_t PlocSupervisorHandler::getTransitionDelayMs(Mode_t modeFrom, Mode_t modeTo){
|
|
|
|
return 500;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::initializeLocalDataPool(localpool::DataPool& localDataPoolMap,
|
|
|
|
LocalDataPoolManager& poolManager) {
|
|
|
|
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::NUM_TMS, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::TEMP_PS, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::TEMP_PL, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::SOC_STATE, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::NVM0_1_STATE, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::NVM3_STATE, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::MISSION_IO_STATE, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::FMC_STATE, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::NUM_TCS, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::UPTIME, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::CPULOAD, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::AVAILABLEHEAP, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
|
2021-07-24 13:57:05 +02:00
|
|
|
localDataPoolMap.emplace(PLOC_SPV::BOOT_SIGNAL, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::RESET_COUNTER, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::BOOT_AFTER_MS, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::BOOT_TIMEOUT_MS, new PoolEntry<uint32_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::ACTIVE_NVM, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::BP0_STATE, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::BP1_STATE, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
localDataPoolMap.emplace(PLOC_SPV::BP2_STATE, new PoolEntry<uint8_t>( { 0 }));
|
|
|
|
|
2021-07-13 08:32:14 +02:00
|
|
|
return HasReturnvaluesIF::RETURN_OK;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::verifyPacket(const uint8_t* start, size_t foundLen) {
|
|
|
|
|
|
|
|
uint16_t receivedCrc = *(start + foundLen - 2) << 8 | *(start + foundLen - 1);
|
|
|
|
|
|
|
|
uint16_t recalculatedCrc = CRC::crc16ccitt(start, foundLen - 2);
|
|
|
|
|
|
|
|
if (receivedCrc != recalculatedCrc) {
|
|
|
|
return CRC_FAILURE;
|
|
|
|
}
|
|
|
|
|
|
|
|
return RETURN_OK;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::handleAckReport(const uint8_t* data) {
|
|
|
|
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
|
|
|
|
result = verifyPacket(data, PLOC_SPV::SIZE_ACK_REPORT);
|
|
|
|
if(result == CRC_FAILURE) {
|
|
|
|
sif::error << "PlocSupervisorHandler::handleAckReport: CRC failure" << std::endl;
|
|
|
|
nextReplyId = PLOC_SPV::NONE;
|
|
|
|
replyRawReplyIfnotWiretapped(data, PLOC_SPV::SIZE_ACK_REPORT);
|
|
|
|
triggerEvent(SUPV_CRC_FAILURE_EVENT);
|
|
|
|
sendFailureReport(PLOC_SPV::ACK_REPORT, CRC_FAILURE);
|
|
|
|
disableAllReplies();
|
2021-07-23 13:27:58 +02:00
|
|
|
return RETURN_OK;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|
|
|
|
|
|
|
|
uint16_t apid = (*(data) << 8 | *(data + 1)) & APID_MASK;
|
|
|
|
|
|
|
|
switch(apid) {
|
|
|
|
case PLOC_SPV::APID_ACK_FAILURE: {
|
|
|
|
//TODO: Interpretation of status field in acknowledgment report
|
|
|
|
sif::debug << "PlocSupervisorHandler::handleAckReport: Received Ack failure report" << std::endl;
|
|
|
|
DeviceCommandId_t commandId = getPendingCommand();
|
|
|
|
if (commandId != DeviceHandlerIF::NO_COMMAND_ID) {
|
|
|
|
triggerEvent(SUPV_ACK_FAILURE, commandId);
|
|
|
|
}
|
|
|
|
sendFailureReport(PLOC_SPV::ACK_REPORT, RECEIVED_ACK_FAILURE);
|
|
|
|
disableAllReplies();
|
|
|
|
nextReplyId = PLOC_SPV::NONE;
|
|
|
|
result = IGNORE_REPLY_DATA;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
case PLOC_SPV::APID_ACK_SUCCESS: {
|
|
|
|
setNextReplyId();
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
default: {
|
|
|
|
sif::debug << "PlocSupervisorHandler::handleAckReport: Invalid APID in Ack report" << std::endl;
|
|
|
|
result = RETURN_FAILED;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::handleExecutionReport(const uint8_t* data) {
|
|
|
|
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
|
|
|
|
result = verifyPacket(data, PLOC_SPV::SIZE_EXE_REPORT);
|
|
|
|
if(result == CRC_FAILURE) {
|
|
|
|
sif::error << "PlocSupervisorHandler::handleExecutionReport: CRC failure" << std::endl;
|
|
|
|
nextReplyId = PLOC_SPV::NONE;
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
|
|
|
uint16_t apid = (*(data) << 8 | *(data + 1)) & APID_MASK;
|
|
|
|
|
|
|
|
switch (apid) {
|
|
|
|
case (PLOC_SPV::APID_EXE_SUCCESS): {
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
case (PLOC_SPV::APID_EXE_FAILURE): {
|
|
|
|
//TODO: Interpretation of status field in execution report
|
|
|
|
sif::error << "PlocSupervisorHandler::handleExecutionReport: Received execution failure report"
|
|
|
|
<< std::endl;
|
|
|
|
DeviceCommandId_t commandId = getPendingCommand();
|
|
|
|
if (commandId != DeviceHandlerIF::NO_COMMAND_ID) {
|
|
|
|
triggerEvent(SUPV_EXE_FAILURE, commandId);
|
|
|
|
}
|
|
|
|
else {
|
|
|
|
sif::debug << "PlocSupervisorHandler::handleExecutionReport: Unknown command id" << std::endl;
|
|
|
|
}
|
|
|
|
sendFailureReport(PLOC_SPV::EXE_REPORT, RECEIVED_EXE_FAILURE);
|
|
|
|
disableExeReportReply();
|
|
|
|
result = IGNORE_REPLY_DATA;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
default: {
|
|
|
|
sif::error << "PlocSupervisorHandler::handleExecutionReport: Unknown APID" << std::endl;
|
|
|
|
result = RETURN_FAILED;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
nextReplyId = PLOC_SPV::NONE;
|
|
|
|
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::handleHkReport(const uint8_t* data) {
|
|
|
|
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
|
|
|
|
result = verifyPacket(data, PLOC_SPV::SIZE_HK_REPORT);
|
|
|
|
|
|
|
|
if(result == CRC_FAILURE) {
|
|
|
|
sif::error << "PlocSupervisorHandler::handleHkReport: Hk report has invalid crc"
|
|
|
|
<< std::endl;
|
|
|
|
}
|
|
|
|
|
|
|
|
uint16_t offset = PLOC_SPV::DATA_FIELD_OFFSET;
|
|
|
|
hkset.tempPs = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
hkset.tempPl = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
hkset.tempSup = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
hkset.uptime = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
hkset.cpuLoad = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
hkset.availableHeap = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
2021-07-22 08:06:04 +02:00
|
|
|
hkset.numTcs = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
hkset.numTms = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
hkset.socState = *(data + offset) << 24 | *(data + offset + 1) << 16 | *(data + offset + 2) << 8
|
|
|
|
| *(data + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
hkset.nvm0_1_state = *(data + offset);
|
|
|
|
offset += 1;
|
|
|
|
hkset.nvm3_state = *(data + offset);
|
|
|
|
offset += 1;
|
|
|
|
hkset.missionIoState = *(data + offset);
|
|
|
|
offset += 1;
|
|
|
|
hkset.fmcState = *(data + offset);
|
|
|
|
offset += 1;
|
2021-07-13 08:32:14 +02:00
|
|
|
|
|
|
|
nextReplyId = PLOC_SPV::EXE_REPORT;
|
|
|
|
|
2021-07-22 08:06:04 +02:00
|
|
|
#if OBSW_VERBOSE_LEVEL >= 1 && PLOC_SUPERVISOR_DEBUG == 1
|
2021-07-13 08:32:14 +02:00
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: temp_ps: " << hkset.tempPs << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: temp_pl: " << hkset.tempPl << std::endl;
|
2021-07-22 08:06:04 +02:00
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: temp_sup: " << hkset.tempSup << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: uptime: " << hkset.uptime << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: cpu_load: " << hkset.cpuLoad << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: available_heap: " << hkset.availableHeap << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: num_tcs: " << hkset.numTcs << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: num_tms: " << hkset.numTms << std::endl;
|
2021-07-13 08:32:14 +02:00
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: soc_state: " << hkset.socState << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: nvm0_1_state: "
|
|
|
|
<< static_cast<unsigned int>(hkset.nvm0_1_state.value) << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: nvm3_state: "
|
|
|
|
<< static_cast<unsigned int>(hkset.nvm3_state.value) << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: missoin_io_state: "
|
|
|
|
<< static_cast<unsigned int>(hkset.missionIoState.value) << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleHkReport: fmc_state: "
|
|
|
|
<< static_cast<unsigned int>(hkset.fmcState.value) << std::endl;
|
2021-07-22 08:06:04 +02:00
|
|
|
|
2021-07-13 08:32:14 +02:00
|
|
|
#endif
|
|
|
|
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
2021-07-24 13:57:05 +02:00
|
|
|
ReturnValue_t PlocSupervisorHandler::handleBootStatusReport(const uint8_t* data) {
|
|
|
|
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
|
|
|
|
result = verifyPacket(data, PLOC_SPV::SIZE_BOOT_STATUS_REPORT);
|
|
|
|
|
|
|
|
if(result == CRC_FAILURE) {
|
|
|
|
sif::error << "PlocSupervisorHandler::handleBootStatusReport: Boot status report has invalid"
|
|
|
|
" crc" << std::endl;
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
|
|
|
uint16_t offset = PLOC_SPV::DATA_FIELD_OFFSET;
|
|
|
|
bootStatusReport.bootSignal = *(data + offset);
|
2021-07-25 20:42:24 +02:00
|
|
|
offset += 1;
|
2021-07-24 13:57:05 +02:00
|
|
|
bootStatusReport.resetCounter = *(data + offset);
|
2021-07-25 20:42:24 +02:00
|
|
|
offset += 1;
|
2021-07-24 13:57:05 +02:00
|
|
|
bootStatusReport.bootAfterMs = *(data + offset) << 24 | *(data + offset + 1) << 16 |
|
|
|
|
*(data + offset + 2) << 8 | *(data + offset + 3);
|
2021-07-25 20:42:24 +02:00
|
|
|
offset += 4;
|
2021-07-24 13:57:05 +02:00
|
|
|
bootStatusReport.bootTimeoutMs = *(data + offset) << 24 | *(data + offset + 1) << 16 |
|
|
|
|
*(data + offset + 2) << 8 | *(data + offset + 3);
|
2021-07-25 20:42:24 +02:00
|
|
|
offset += 4;
|
2021-07-24 13:57:05 +02:00
|
|
|
bootStatusReport.activeNvm = *(data + offset);
|
2021-07-25 20:42:24 +02:00
|
|
|
offset += 1;
|
2021-07-24 13:57:05 +02:00
|
|
|
bootStatusReport.bp0State = *(data + offset);
|
2021-07-25 20:42:24 +02:00
|
|
|
offset += 1;
|
2021-07-24 13:57:05 +02:00
|
|
|
bootStatusReport.bp1State = *(data + offset);
|
2021-07-25 20:42:24 +02:00
|
|
|
offset += 1;
|
2021-07-24 13:57:05 +02:00
|
|
|
bootStatusReport.bp2State = *(data + offset);
|
|
|
|
|
|
|
|
nextReplyId = PLOC_SPV::EXE_REPORT;
|
|
|
|
|
|
|
|
#if OBSW_VERBOSE_LEVEL >= 1 && PLOC_SUPERVISOR_DEBUG == 1
|
2021-07-25 20:42:24 +02:00
|
|
|
sif::info << "PlocSupervisorHandler::handleBootStatusReport: Boot signal: "
|
|
|
|
<< static_cast<unsigned int>(bootStatusReport.bootSignal.value) << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleBootStatusReport: Reset counter: "
|
|
|
|
<< static_cast<unsigned int>(bootStatusReport.resetCounter.value) << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleBootStatusReport: BootAfterMs: "
|
|
|
|
<< bootStatusReport.bootAfterMs << " ms" << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleBootStatusReport: BootTimeoutMs: "
|
|
|
|
<< bootStatusReport.bootTimeoutMs << " ms" << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleBootStatusReport: Active NVM: "
|
|
|
|
<< static_cast<unsigned int>(bootStatusReport.activeNvm.value) << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleBootStatusReport: BP0: "
|
|
|
|
<< static_cast<unsigned int>(bootStatusReport.bp0State.value) << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleBootStatusReport: BP1: "
|
|
|
|
<< static_cast<unsigned int>(bootStatusReport.bp1State.value) << std::endl;
|
|
|
|
sif::info << "PlocSupervisorHandler::handleBootStatusReport: BP2: "
|
|
|
|
<< static_cast<unsigned int>(bootStatusReport.bp2State.value) << std::endl;
|
2021-07-24 13:57:05 +02:00
|
|
|
#endif
|
|
|
|
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
2021-07-13 08:32:14 +02:00
|
|
|
ReturnValue_t PlocSupervisorHandler::enableReplyInReplyMap(DeviceCommandMap::iterator command,
|
|
|
|
uint8_t expectedReplies, bool useAlternateId,
|
|
|
|
DeviceCommandId_t alternateReplyID) {
|
|
|
|
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
|
|
|
|
uint8_t enabledReplies = 0;
|
|
|
|
|
|
|
|
switch (command->first) {
|
|
|
|
case PLOC_SPV::GET_HK_REPORT: {
|
|
|
|
enabledReplies = 3;
|
|
|
|
result = DeviceHandlerBase::enableReplyInReplyMap(command, enabledReplies, true,
|
|
|
|
PLOC_SPV::HK_REPORT);
|
|
|
|
if (result != RETURN_OK) {
|
|
|
|
sif::debug << "PlocSupervisorHandler::enableReplyInReplyMap: Reply with id "
|
|
|
|
<< PLOC_SPV::HK_REPORT << " not in replyMap" << std::endl;
|
|
|
|
}
|
|
|
|
break;
|
|
|
|
}
|
2021-07-25 20:42:24 +02:00
|
|
|
case PLOC_SPV::GET_BOOT_STATUS_REPORT: {
|
|
|
|
enabledReplies = 3;
|
|
|
|
result = DeviceHandlerBase::enableReplyInReplyMap(command, enabledReplies, true,
|
|
|
|
PLOC_SPV::BOOT_STATUS_REPORT);
|
|
|
|
if (result != RETURN_OK) {
|
|
|
|
sif::debug << "PlocSupervisorHandler::enableReplyInReplyMap: Reply with id "
|
|
|
|
<< PLOC_SPV::BOOT_STATUS_REPORT << " not in replyMap" << std::endl;
|
|
|
|
}
|
|
|
|
break;
|
|
|
|
}
|
2021-07-13 08:32:14 +02:00
|
|
|
case PLOC_SPV::RESTART_MPSOC:
|
|
|
|
case PLOC_SPV::START_MPSOC:
|
|
|
|
case PLOC_SPV::SHUTDOWN_MPSOC:
|
|
|
|
case PLOC_SPV::SEL_MPSOC_BOOT_IMAGE:
|
|
|
|
case PLOC_SPV::SET_BOOT_TIMEOUT:
|
|
|
|
case PLOC_SPV::SET_MAX_RESTART_TRIES:
|
|
|
|
case PLOC_SPV::RESET_MPSOC:
|
|
|
|
case PLOC_SPV::SET_TIME_REF:
|
|
|
|
enabledReplies = 2;
|
|
|
|
break;
|
|
|
|
default:
|
|
|
|
sif::debug << "PlocSupervisorHandler::enableReplyInReplyMap: Unknown command id" << std::endl;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Every command causes at least one acknowledgment and one execution report. Therefore both
|
|
|
|
* replies will be enabled here.
|
|
|
|
*/
|
|
|
|
result = DeviceHandlerBase::enableReplyInReplyMap(command, enabledReplies, true,
|
|
|
|
PLOC_SPV::ACK_REPORT);
|
|
|
|
if (result != RETURN_OK) {
|
|
|
|
sif::debug << "PlocSupervisorHandler::enableReplyInReplyMap: Reply with id "
|
|
|
|
<< PLOC_SPV::ACK_REPORT << " not in replyMap" << std::endl;
|
|
|
|
}
|
|
|
|
|
|
|
|
result = DeviceHandlerBase::enableReplyInReplyMap(command, enabledReplies, true,
|
|
|
|
PLOC_SPV::EXE_REPORT);
|
|
|
|
if (result != RETURN_OK) {
|
|
|
|
sif::debug << "PlocSupervisorHandler::enableReplyInReplyMap: Reply with id "
|
|
|
|
<< PLOC_SPV::EXE_REPORT << " not in replyMap" << std::endl;
|
|
|
|
}
|
|
|
|
|
|
|
|
return RETURN_OK;
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::setNextReplyId() {
|
|
|
|
switch(getPendingCommand()) {
|
|
|
|
case PLOC_SPV::GET_HK_REPORT:
|
|
|
|
nextReplyId = PLOC_SPV::HK_REPORT;
|
|
|
|
break;
|
2021-07-26 12:08:38 +02:00
|
|
|
case PLOC_SPV::GET_BOOT_STATUS_REPORT:
|
|
|
|
nextReplyId = PLOC_SPV::BOOT_STATUS_REPORT;
|
|
|
|
break;
|
2021-07-13 08:32:14 +02:00
|
|
|
default:
|
|
|
|
/* If no telemetry is expected the next reply is always the execution report */
|
|
|
|
nextReplyId = PLOC_SPV::EXE_REPORT;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
size_t PlocSupervisorHandler::getNextReplyLength(DeviceCommandId_t commandId){
|
|
|
|
|
|
|
|
size_t replyLen = 0;
|
|
|
|
|
|
|
|
if (nextReplyId == PLOC_SPV::NONE) {
|
|
|
|
return replyLen;
|
|
|
|
}
|
|
|
|
|
|
|
|
DeviceReplyIter iter = deviceReplyMap.find(nextReplyId);
|
|
|
|
if (iter != deviceReplyMap.end()) {
|
|
|
|
if (iter->second.delayCycles == 0) {
|
|
|
|
/* Reply inactive */
|
|
|
|
return replyLen;
|
|
|
|
}
|
|
|
|
replyLen = iter->second.replyLen;
|
|
|
|
}
|
|
|
|
else {
|
|
|
|
sif::debug << "PlocSupervisorHandler::getNextReplyLength: No entry for reply with reply id "
|
|
|
|
<< std::hex << nextReplyId << " in deviceReplyMap" << std::endl;
|
|
|
|
}
|
|
|
|
|
|
|
|
return replyLen;
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::handleDeviceTM(const uint8_t* data, size_t dataSize, DeviceCommandId_t replyId) {
|
|
|
|
|
|
|
|
ReturnValue_t result = RETURN_OK;
|
|
|
|
|
|
|
|
if (wiretappingMode == RAW) {
|
|
|
|
/* Data already sent in doGetRead() */
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
DeviceReplyMap::iterator iter = deviceReplyMap.find(replyId);
|
|
|
|
if (iter == deviceReplyMap.end()) {
|
|
|
|
sif::debug << "PlocSupervisorHandler::handleDeviceTM: Unknown reply id" << std::endl;
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
MessageQueueId_t queueId = iter->second.command->second.sendReplyTo;
|
|
|
|
|
|
|
|
if (queueId == NO_COMMANDER) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
result = actionHelper.reportData(queueId, replyId, data, dataSize);
|
|
|
|
if (result != RETURN_OK) {
|
|
|
|
sif::debug << "PlocSupervisorHandler::handleDeviceTM: Failed to report data" << std::endl;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::prepareEmptyCmd(uint16_t apid) {
|
|
|
|
PLOC_SPV::EmptyPacket packet(apid);
|
|
|
|
memcpy(commandBuffer, packet.getWholeData(), packet.getFullSize());
|
|
|
|
rawPacket = commandBuffer;
|
|
|
|
rawPacketLen = packet.getFullSize();
|
|
|
|
nextReplyId = PLOC_SPV::ACK_REPORT;
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::prepareSelBootImageCmd(const uint8_t * commandData) {
|
|
|
|
PLOC_SPV::MPSoCBootSelect packet(*commandData, *(commandData + 1), *(commandData + 2),
|
|
|
|
*(commandData + 3));
|
|
|
|
memcpy(commandBuffer, packet.getWholeData(), packet.getFullSize());
|
|
|
|
rawPacket = commandBuffer;
|
|
|
|
rawPacketLen = packet.getFullSize();
|
|
|
|
nextReplyId = PLOC_SPV::ACK_REPORT;
|
|
|
|
}
|
|
|
|
|
|
|
|
ReturnValue_t PlocSupervisorHandler::prepareSetTimeRefCmd() {
|
|
|
|
Clock::TimeOfDay_t time;
|
|
|
|
ReturnValue_t result = Clock::getDateAndTime(&time);
|
|
|
|
if (result != RETURN_OK) {
|
|
|
|
sif::warning << "PlocSupervisorHandler::prepareSetTimeRefCmd: Failed to get current time"
|
|
|
|
<< std::endl;
|
|
|
|
return GET_TIME_FAILURE;
|
|
|
|
}
|
|
|
|
PLOC_SPV::SetTimeRef packet(&time);
|
|
|
|
memcpy(commandBuffer, packet.getWholeData(), packet.getFullSize());
|
|
|
|
rawPacket = commandBuffer;
|
|
|
|
rawPacketLen = packet.getFullSize();
|
|
|
|
nextReplyId = PLOC_SPV::ACK_REPORT;
|
|
|
|
return RETURN_OK;
|
|
|
|
}
|
|
|
|
|
2021-07-22 08:06:04 +02:00
|
|
|
void PlocSupervisorHandler::prepareDisableHk() {
|
|
|
|
PLOC_SPV::DisablePeriodicHkTransmission packet;
|
|
|
|
memcpy(commandBuffer, packet.getWholeData(), packet.getFullSize());
|
|
|
|
rawPacket = commandBuffer;
|
|
|
|
rawPacketLen = packet.getFullSize();
|
|
|
|
nextReplyId = PLOC_SPV::ACK_REPORT;
|
|
|
|
}
|
|
|
|
|
2021-07-13 08:32:14 +02:00
|
|
|
void PlocSupervisorHandler::prepareSetBootTimeoutCmd(const uint8_t * commandData) {
|
|
|
|
uint32_t timeout = *(commandData) << 24 | *(commandData + 1) << 16 | *(commandData + 2) << 8
|
|
|
|
| *(commandData + 3);
|
|
|
|
PLOC_SPV::SetBootTimeout packet(timeout);
|
|
|
|
memcpy(commandBuffer, packet.getWholeData(), packet.getFullSize());
|
2021-07-22 08:06:04 +02:00
|
|
|
rawPacket = commandBuffer;
|
|
|
|
rawPacketLen = packet.getFullSize();
|
|
|
|
nextReplyId = PLOC_SPV::ACK_REPORT;
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::prepareRestartTriesCmd(const uint8_t * commandData) {
|
|
|
|
uint8_t restartTries = *(commandData);
|
|
|
|
PLOC_SPV::SetRestartTries packet(restartTries);
|
|
|
|
memcpy(commandBuffer, packet.getWholeData(), packet.getFullSize());
|
2021-07-25 20:42:24 +02:00
|
|
|
rawPacket = commandBuffer;
|
|
|
|
rawPacketLen = packet.getFullSize();
|
|
|
|
nextReplyId = PLOC_SPV::ACK_REPORT;
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::prepareUpdateAvailableCmd(const uint8_t * commandData) {
|
|
|
|
uint8_t offset = 0;
|
|
|
|
uint8_t imageSelect = *(commandData + offset);
|
|
|
|
offset += 1;
|
|
|
|
uint8_t imagePartition = *(commandData + offset);
|
|
|
|
offset += 1;
|
|
|
|
uint32_t imageSize = *(commandData + offset) << 24 | *(commandData + offset + 1) << 16
|
|
|
|
| *(commandData + offset + 2) << 8 | *(commandData + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
uint32_t imageCrc = *(commandData + offset) << 24 | *(commandData + offset + 1) << 16
|
|
|
|
| *(commandData + offset + 2) << 8 | *(commandData + offset + 3);
|
|
|
|
offset += 4;
|
|
|
|
uint32_t numberOfPackets = *(commandData + offset) << 24 | *(commandData + offset + 1) << 16
|
|
|
|
| *(commandData + offset + 2) << 8 | *(commandData + offset + 3);
|
|
|
|
|
|
|
|
PLOC_SPV::UpdateAvailable packet(imageSelect, imagePartition, imageSize, imageCrc,
|
|
|
|
numberOfPackets);
|
|
|
|
memcpy(commandBuffer, packet.getWholeData(), packet.getFullSize());
|
2021-07-13 08:32:14 +02:00
|
|
|
rawPacket = commandBuffer;
|
|
|
|
rawPacketLen = packet.getFullSize();
|
|
|
|
nextReplyId = PLOC_SPV::ACK_REPORT;
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::disableAllReplies() {
|
|
|
|
|
|
|
|
DeviceReplyMap::iterator iter;
|
|
|
|
|
|
|
|
/* Disable ack reply */
|
|
|
|
iter = deviceReplyMap.find(PLOC_SPV::ACK_REPORT);
|
|
|
|
DeviceReplyInfo *info = &(iter->second);
|
|
|
|
info->delayCycles = 0;
|
|
|
|
info->command = deviceCommandMap.end();
|
|
|
|
|
|
|
|
DeviceCommandId_t commandId = getPendingCommand();
|
|
|
|
|
|
|
|
/* If the command expects a telemetry packet the appropriate tm reply will be disabled here */
|
|
|
|
switch (commandId) {
|
2021-07-23 13:27:58 +02:00
|
|
|
case PLOC_SPV::GET_HK_REPORT: {
|
|
|
|
iter = deviceReplyMap.find(PLOC_SPV::GET_HK_REPORT);
|
2021-07-13 08:32:14 +02:00
|
|
|
info = &(iter->second);
|
|
|
|
info->delayCycles = 0;
|
|
|
|
info->command = deviceCommandMap.end();
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
default: {
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
/* We must always disable the execution report reply here */
|
|
|
|
disableExeReportReply();
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::sendFailureReport(DeviceCommandId_t replyId, ReturnValue_t status) {
|
|
|
|
|
|
|
|
DeviceReplyIter iter = deviceReplyMap.find(replyId);
|
|
|
|
|
|
|
|
if (iter == deviceReplyMap.end()) {
|
|
|
|
sif::debug << "PlocSupervisorHandler::sendFailureReport: Reply not in reply map" << std::endl;
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
DeviceCommandInfo* info = &(iter->second.command->second);
|
|
|
|
|
|
|
|
if (info == nullptr) {
|
|
|
|
sif::debug << "PlocSupervisorHandler::sendFailureReport: Reply has no active command" << std::endl;
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (info->sendReplyTo != NO_COMMANDER) {
|
|
|
|
actionHelper.finish(false, info->sendReplyTo, iter->first, status);
|
|
|
|
}
|
|
|
|
info->isExecuting = false;
|
|
|
|
}
|
|
|
|
|
|
|
|
void PlocSupervisorHandler::disableExeReportReply() {
|
|
|
|
DeviceReplyIter iter = deviceReplyMap.find(PLOC_SPV::EXE_REPORT);
|
|
|
|
DeviceReplyInfo *info = &(iter->second);
|
|
|
|
info->delayCycles = 0;
|
|
|
|
info->command = deviceCommandMap.end();
|
|
|
|
/* Expected replies is set to one here. The value will set to 0 in replyToReply() */
|
2021-07-23 13:27:58 +02:00
|
|
|
info->command->second.expectedReplies = 1;
|
2021-07-13 08:32:14 +02:00
|
|
|
}
|