7900;RF_AVAILABLE;INFO;A RF available signal was detected. P1: raw RFA state, P2: 0;/home/rmueller/EIVE/eive-obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
7901;RF_LOST;INFO;A previously found RF available signal was lost. P1: raw RFA state, P2: 0;/home/rmueller/EIVE/eive-obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
7902;BIT_LOCK;INFO;A Bit Lock signal. Was detected. P1: raw BLO state, P2: 0;/home/rmueller/EIVE/eive-obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
7903;BIT_LOCK_LOST;INFO;A previously found Bit Lock signal was lost. P1: raw BLO state, P2: 0;/home/rmueller/EIVE/eive-obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
7905;FRAME_PROCESSING_FAILED;LOW;The CCSDS Board could not interpret a TC;/home/rmueller/EIVE/eive-obsw/fsfw/src/fsfw/datalinklayer/DataLinkLayer.h
11201;SELF_TEST_I2C_FAILURE;LOW;Get self test result returns I2C failure P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;/home/rmueller/EIVE/eive-obsw/mission/devices/IMTQHandler.h
11202;SELF_TEST_SPI_FAILURE;LOW;Get self test result returns SPI failure. This concerns the MTM connectivity. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;/home/rmueller/EIVE/eive-obsw/mission/devices/IMTQHandler.h
11203;SELF_TEST_ADC_FAILURE;LOW;Get self test result returns failure in measurement of current and temperature. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;/home/rmueller/EIVE/eive-obsw/mission/devices/IMTQHandler.h
11204;SELF_TEST_PWM_FAILURE;LOW;Get self test result returns PWM failure which concerns the coil actuation. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;/home/rmueller/EIVE/eive-obsw/mission/devices/IMTQHandler.h
11205;SELF_TEST_TC_FAILURE;LOW;Get self test result returns TC failure (system failure) P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;/home/rmueller/EIVE/eive-obsw/mission/devices/IMTQHandler.h
11206;SELF_TEST_MTM_RANGE_FAILURE;LOW;Get self test result returns failure that MTM values were outside of the expected range. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;/home/rmueller/EIVE/eive-obsw/mission/devices/IMTQHandler.h
11207;SELF_TEST_COIL_CURRENT_FAILURE;LOW;Get self test result returns failure indicating that the coil current was outside of the expected range P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;/home/rmueller/EIVE/eive-obsw/mission/devices/IMTQHandler.h
11208;INVALID_ERROR_BYTE;LOW;Received invalid error byte. This indicates an error of the communication link between IMTQ and OBC.;/home/rmueller/EIVE/eive-obsw/mission/devices/IMTQHandler.h
11301;ERROR_STATE;HIGH;Reaction wheel signals an error state;/home/rmueller/EIVE/eive-obsw/mission/devices/RwHandler.h
11501;SUPV_MEMORY_READ_RPT_CRC_FAILURE;LOW;PLOC supervrisor crc failure in telemetry packet;/home/rmueller/EIVE/eive-obsw/mission/devices/PlocSupervisorHandler.h
11502;SUPV_ACK_FAILURE;LOW;PLOC supervisor received acknowledgment failure report;/home/rmueller/EIVE/eive-obsw/mission/devices/PlocSupervisorHandler.h
11503;SUPV_EXE_FAILURE;LOW;PLOC received execution failure report;/home/rmueller/EIVE/eive-obsw/mission/devices/PlocSupervisorHandler.h
11504;SUPV_CRC_FAILURE_EVENT;LOW;PLOC supervisor reply has invalid crc;/home/rmueller/EIVE/eive-obsw/mission/devices/PlocSupervisorHandler.h