Merge branch 'v3.0.0-dev' into acs-ptg-ctrl-fixes-2
Some checks are pending
EIVE/eive-obsw/pipeline/pr-v3.0.0-dev Build started...
Some checks are pending
EIVE/eive-obsw/pipeline/pr-v3.0.0-dev Build started...
This commit is contained in:
commit
376c359d6e
@ -16,7 +16,7 @@ will consitute of a breaking change warranting a new major release:
|
||||
|
||||
# [unreleased]
|
||||
|
||||
# [v2.2.0] to be released
|
||||
# [v4.0.0] to be released
|
||||
|
||||
# [v3.0.0] to be released
|
||||
|
||||
@ -94,6 +94,7 @@ will consitute of a breaking change warranting a new major release:
|
||||
- Prevent spam of TCS controller heater unavailability event if all heaters are in external control.
|
||||
- TCS heater switch info set contained invalid values because of a faulty `memcpy` in the TCS
|
||||
controller. There is not crash risk but the heater states were invalid.
|
||||
- STR datasets were not set to invalid on shutdown.
|
||||
- Fixed usage of quaternion valid flag, which does not actually represent the validity of the
|
||||
quaternion.
|
||||
- Various fixes for the pointing modes of the `ACS Controller`. All modes should work now as
|
||||
|
@ -100,6 +100,19 @@ void StarTrackerHandler::doShutDown() {
|
||||
startupState = StartupState::IDLE;
|
||||
bootState = FwBootState::NONE;
|
||||
solutionSet.setReportingEnabled(false);
|
||||
{
|
||||
PoolReadGuard pg(&solutionSet);
|
||||
solutionSet.caliQw.value = 0.0;
|
||||
solutionSet.caliQx.value = 0.0;
|
||||
solutionSet.caliQy.value = 0.0;
|
||||
solutionSet.caliQz.value = 0.0;
|
||||
solutionSet.isTrustWorthy = 0;
|
||||
solutionSet.setValidity(false, true);
|
||||
}
|
||||
{
|
||||
PoolReadGuard pg(&temperatureSet);
|
||||
temperatureSet.setValidity(false, true);
|
||||
}
|
||||
reinitNextSetParam = false;
|
||||
setMode(_MODE_POWER_DOWN);
|
||||
}
|
||||
|
Loading…
Reference in New Issue
Block a user