* @brief Device Handler for the thermal sensors
|
||||
* @details
|
||||
* Documentation of devices:
|
||||
* MAX31865 RTD converter:
|
||||
* https://datasheets.maximintegrated.com/en/ds/MAX31865.pdf
|
||||
* Pt1000 platinum resistance thermometers OMEGA F2020-1000-1/3B:
|
||||
* https://br.omega.com/omegaFiles/temperature/pdf/F1500_F2000_F4000.pdf
|
||||
*
|
||||
* The thermal sensor values are measured using the MAX31865 RTD converter IC
|
||||
* which creates digital values from the measured resistance of the Pt1000
|
||||
* devices which can be read with the SPI interface.
|
||||
* Refer to the SOURCE system schematic for the exact setup and number
|
||||
* of devices.
|
||||
*
|
||||
* @author R. Mueller
|
||||
* @ingroup devices
|
||||
*/
|
||||
class Max31865PT1000Handler : public DeviceHandlerBase {
|
||||
public:
|
||||
Max31865PT1000Handler(object_id_t objectId, object_id_t comIF, CookieIF *comCookie);
|
||||
virtual ~Max31865PT1000Handler();
|
||||
|
||||
void setDebugMode(bool enable);
|
||||
|
||||
// Configuration in 8 digit code:
|
||||
// 1. 1 for V_BIAS enabled, 0 for disabled
|
||||
// 2. 1 for Auto-conversion, 0 for off
|
||||
// 3. 1 for 1-shot enabled, 0 for disabled (self-clearing bit)
|
||||
// 4. 1 for 3-wire enabled, 0 for disabled (two and four wired RTD)
|
||||
// 5./6. Fault detection: 00 for no action, 01 for automatic delay, 1
|
||||
// 0 for run fault detection with manual delay,
|
||||
// 11 for finish fault detection with manual delay
|
||||
// 7. Fault status: Write 1 to reset fault status register (Bit is self cleared afterwards)
|
||||
// 8. 1 for 50 Hz filter, 0 for 60 Hz filter (noise rejection filter)
|
||||
static constexpr uint8_t DEFAULT_CONFIG = 0b11000001;
|
||||
|
||||
void setInstantNormal(bool instantNormal);
|
||||
void setDeviceInfo(uint8_t idx, std::string locString);
|
||||
|
||||
/**
|
||||
* Expected temperature range is -100 C and 100 C.
|
||||
* If there are temperatures beyond this range there must be a fault.
|
||||
* The threshold variables cause the MAX1385 to signal an error in case the measured resistance
|
||||
* indicates a temperature higher than 100 C or lower than -100 C.
|
||||
* Default settings of MAX13865 are 0xFFFF for the high threshold register and 0x0 for the
|
||||
* low threshold register.
|
||||
*/
|
||||
static constexpr uint16_t HIGH_THRESHOLD = 11298; // = 100 C
|
||||
static constexpr uint16_t LOW_THRESHOLD = 4902; // = -100 C
|
||||
|
||||
static constexpr float RTD_RESISTANCE0_PT1000 = 1000.0; //!< Ohm
|
||||
protected:
|
||||
// DeviceHandlerBase abstract function implementation
|
||||
void doStartUp() override;
|
||||
void doShutDown() override;
|
||||
ReturnValue_t buildNormalDeviceCommand(DeviceCommandId_t *id) override;
|
||||
ReturnValue_t buildTransitionDeviceCommand(DeviceCommandId_t *id) override;
|
||||
ReturnValue_t buildCommandFromCommand(DeviceCommandId_t deviceCommand, const uint8_t *commandData,
|
||||
size_t commandDataLen) override;
|
||||
void fillCommandAndReplyMap() override;
|
||||
ReturnValue_t scanForReply(const uint8_t *start, size_t remainingSize, DeviceCommandId_t *foundId,
|
||||
size_t *foundLen) override;
|
||||
ReturnValue_t interpretDeviceReply(DeviceCommandId_t id, const uint8_t *packet) override;
|
||||
uint32_t getTransitionDelayMs(Mode_t modeFrom, Mode_t modeTo) override;
|
||||
ReturnValue_t getSwitches(const uint8_t **switches, uint8_t *numberOfSwitches) override;
|
||||
ReturnValue_t initializeLocalDataPool(localpool::DataPool &localDataPoolMap,
|
||||
LocalDataPoolManager &poolManager) override;
|
||||
void modeChanged() override;
|
||||
bool shouldFaultStatusBeRequested(bool faultBit);
|
||||
|
||||
private:
|
||||
uint8_t switchId = 0;
|
||||
bool instantNormal = false;
|
||||
bool debugMode = false;
|
||||
bool warningSwitch = true;
|
||||
|
||||
enum class InternalState {
|
||||
NONE,
|
||||
WARMUP,
|
||||
CONFIGURE,
|
||||
CONFIG_HIGH_THRESHOLD,
|
||||
REQUEST_HIGH_THRESHOLD,
|
||||
CONFIG_LOW_THRESHOLD,
|
||||
REQUEST_LOW_THRESHOLD,
|
||||
REQUEST_CONFIG,
|
||||
RUNNING,
|
||||
REQUEST_FAULT_BYTE,
|
||||
CLEAR_FAULT_BYTE
|
||||
};
|
||||
|
||||
InternalState internalState = InternalState::NONE;
|
||||
bool commandExecuted = false;
|
||||
|
||||
bool resetFaultBit = false;
|
||||
dur_millis_t startTime = 0;
|
||||
uint8_t currentCfg = 0;
|
||||
uint8_t currentFaultStatus = 0;
|
||||
uint8_t lastFaultStatus = 0;
|
||||
uint16_t sameFaultStatusCounter = 0;
|
||||
std::string locString;
|
||||
uint8_t deviceIdx = 0;
|
||||
std::array<uint8_t, 3> commandBuffer{0};
|
||||
|
||||
MAX31865::PrimarySet sensorDataset;
|
||||
sid_t sensorDatasetSid;
|
||||
|
||||
#if OBSW_VERBOSE_LEVEL >= 1
|
||||
PeriodicOperationDivider *debugDivider;
|
||||
#endif
|
||||
};
|
||||
|
||||
#endif /* MISSION_TCS_MAX31865PT1000HANDLER_H_ */
|
Reference in New Issue
Block a user