reduced transmitter timeout to 2 minutes
Some checks are pending
EIVE/eive-obsw/pipeline/head Build started...
EIVE/eive-obsw/pipeline/pr-develop This commit looks good

This commit is contained in:
Jakob Meier 2023-03-07 07:26:09 +01:00
parent 6aae94823e
commit ca7fbcf6a9
2 changed files with 9 additions and 2 deletions

View File

@ -16,6 +16,12 @@ will consitute of a breaking change warranting a new major release:
# [unreleased] # [unreleased]
## Changed
- Transmitter timeout set to 2 minutes instead of 15 minutes. This will prevent to discharge the battery
in case the syrlinks starts transmitting due to detection of unintentional bitlock. This happened e.g. on ground
when the uplink to the flying latop was established.
# [v1.35.1] 2023-03-04 # [v1.35.1] 2023-03-04
## Fixed ## Fixed

View File

@ -11,8 +11,9 @@ extern ComSubsystem SUBSYSTEM;
// The syrlinks must not transmitting longer then 15 minutes otherwise the // The syrlinks must not transmitting longer then 15 minutes otherwise the
// transceiver might be damaged due to overheating // transceiver might be damaged due to overheating
// 15 minutes in milliseconds // This is the initial timeout of 2 minutes. The timeout needs to be incremented
static const uint32_t TRANSMITTER_TIMEOUT = 900000; // before each overpass
static const uint32_t TRANSMITTER_TIMEOUT = 120000;
Subsystem& init(); Subsystem& init();
} // namespace com } // namespace com