add health handling for TCS ASSY #436
@ -19,6 +19,11 @@ will consitute of a breaking change warranting a new major release:
|
|||||||
## Fixed
|
## Fixed
|
||||||
|
|
||||||
- Health handling for TCS board assembly
|
- Health handling for TCS board assembly
|
||||||
|
## Changed
|
||||||
|
|
||||||
|
- Transmitter timeout set to 2 minutes instead of 15 minutes. This will prevent to discharge the battery
|
||||||
|
in case the syrlinks starts transmitting due to detection of unintentional bitlock. This happened e.g. on ground
|
||||||
|
when the uplink to the flying latop was established.
|
||||||
|
|
||||||
# [v1.35.1] 2023-03-04
|
# [v1.35.1] 2023-03-04
|
||||||
|
|
||||||
|
@ -11,8 +11,9 @@ extern ComSubsystem SUBSYSTEM;
|
|||||||
|
|
||||||
// The syrlinks must not transmitting longer then 15 minutes otherwise the
|
// The syrlinks must not transmitting longer then 15 minutes otherwise the
|
||||||
// transceiver might be damaged due to overheating
|
// transceiver might be damaged due to overheating
|
||||||
// 15 minutes in milliseconds
|
// This is the initial timeout of 2 minutes. The timeout needs to be incremented
|
||||||
static const uint32_t TRANSMITTER_TIMEOUT = 900000;
|
// before each overpass
|
||||||
|
static const uint32_t TRANSMITTER_TIMEOUT = 120000;
|
||||||
|
|
||||||
Subsystem& init();
|
Subsystem& init();
|
||||||
} // namespace com
|
} // namespace com
|
||||||
|