GYR Bias Update #499

Merged
muellerr merged 2 commits from new-gyr-bias into develop 2023-03-20 17:54:47 +01:00
2 changed files with 9 additions and 4 deletions

View File

@ -21,6 +21,11 @@ will consitute of a breaking change warranting a new major release:
- Fixed transition for dual power lane assemblies: When going from dual side submode to single side
submode, perform logical commanding first, similarly to when going to OFF mode.
## Changed
- Updated GYR bias values to newest measurements. This also corrects the ADIS values to always
consit of just one digit.
# [v1.38.0] 2023-03-17
eive-tmtc: v2.19.2

View File

@ -768,10 +768,10 @@ class AcsParameters : public HasParametersIF {
double gyr2orientationMatrix[3][3] = {{0, 0, -1}, {0, -1, 0}, {-1, 0, 0}};
double gyr3orientationMatrix[3][3] = {{0, 0, -1}, {0, 1, 0}, {1, 0, 0}};
double gyr0bias[3] = {0.06318149743589743, 0.4283235025641024, -0.16383500000000004};
double gyr1bias[3] = {-0.12855128205128205, 1.6737307692307695, 1.031724358974359};
double gyr2bias[3] = {0.15039212820512823, 0.7094475589743591, -0.22298363589743594};
double gyr3bias[3] = {0.0021730769230769217, -0.6655897435897435, 0.034096153846153845};
double gyr0bias[3] = {0.0, 0.4, -0.1};
double gyr1bias[3] = {0.0956745283018868, 2.0854575471698116, 1.2505990566037737};
double gyr2bias[3] = {0.1, 0.7, -0.2};
double gyr3bias[3] = {-0.10721698113207549, -0.6111650943396226, 0.1716462264150944};
/* var = sigma^2, sigma = RND*sqrt(freq), following values are RND^2 and not var as freq is
* assumed to be equal for the same class of sensors */