TCS local pool variables as members #515

Merged
muellerr merged 3 commits from thermal_ctrl_local_vars_as_members into develop 2023-03-23 18:39:11 +01:00
3 changed files with 48 additions and 40 deletions
Showing only changes of commit 7af2b5ddf9 - Show all commits

View File

@ -605,7 +605,6 @@ void ThermalController::copySus() {
} }
void ThermalController::copyDevices() { void ThermalController::copyDevices() {
lp_var_t<float> tempQ7s = lp_var_t<float>(objects::CORE_CONTROLLER, core::PoolIds::TEMPERATURE);
{ {
PoolReadGuard pg(&tempQ7s, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempQ7s, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() == returnvalue::OK) { if (pg.getReadResult() == returnvalue::OK) {
@ -618,8 +617,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int16_t> battTemp1 =
lp_var_t<int16_t>(objects::BPX_BATT_HANDLER, BpxBattery::BATT_TEMP_1);
PoolReadGuard pg(&battTemp1, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&battTemp1, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read battery temperature 1" << std::endl; sif::warning << "ThermalController: Failed to read battery temperature 1" << std::endl;
@ -632,8 +629,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int16_t> battTemp2 =
lp_var_t<int16_t>(objects::BPX_BATT_HANDLER, BpxBattery::BATT_TEMP_2);
PoolReadGuard pg(&battTemp2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&battTemp2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read battery temperature 2" << std::endl; sif::warning << "ThermalController: Failed to read battery temperature 2" << std::endl;
@ -646,8 +641,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int16_t> battTemp3 =
lp_var_t<int16_t>(objects::BPX_BATT_HANDLER, BpxBattery::BATT_TEMP_3);
PoolReadGuard pg(&battTemp3, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&battTemp3, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read battery temperature 3" << std::endl; sif::warning << "ThermalController: Failed to read battery temperature 3" << std::endl;
@ -660,8 +653,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int16_t> battTemp4 =
lp_var_t<int16_t>(objects::BPX_BATT_HANDLER, BpxBattery::BATT_TEMP_4);
PoolReadGuard pg(&battTemp4, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&battTemp4, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read battery temperature 4" << std::endl; sif::warning << "ThermalController: Failed to read battery temperature 4" << std::endl;
@ -674,7 +665,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int32_t> tempRw1 = lp_var_t<int32_t>(objects::RW1, rws::TEMPERATURE_C);
PoolReadGuard pg(&tempRw1, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempRw1, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read reaction wheel 1 temperature" << std::endl; sif::warning << "ThermalController: Failed to read reaction wheel 1 temperature" << std::endl;
@ -687,7 +677,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int32_t> tempRw2 = lp_var_t<int32_t>(objects::RW2, rws::TEMPERATURE_C);
PoolReadGuard pg(&tempRw2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempRw2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read reaction wheel 2 temperature" << std::endl; sif::warning << "ThermalController: Failed to read reaction wheel 2 temperature" << std::endl;
@ -700,7 +689,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int32_t> tempRw3 = lp_var_t<int32_t>(objects::RW3, rws::TEMPERATURE_C);
PoolReadGuard pg(&tempRw3, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempRw3, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read reaction wheel 3 temperature" << std::endl; sif::warning << "ThermalController: Failed to read reaction wheel 3 temperature" << std::endl;
@ -713,7 +701,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int32_t> tempRw4 = lp_var_t<int32_t>(objects::RW4, rws::TEMPERATURE_C);
PoolReadGuard pg(&tempRw4, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempRw4, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read reaction wheel 4 temperature" << std::endl; sif::warning << "ThermalController: Failed to read reaction wheel 4 temperature" << std::endl;
@ -726,8 +713,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempStartracker =
lp_var_t<float>(objects::STAR_TRACKER, startracker::MCU_TEMPERATURE);
PoolReadGuard pg(&tempStartracker, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempStartracker, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read startracker temperature" << std::endl; sif::warning << "ThermalController: Failed to read startracker temperature" << std::endl;
@ -740,8 +725,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempSyrlinksPowerAmplifier =
lp_var_t<float>(objects::SYRLINKS_HANDLER, syrlinks::TEMP_POWER_AMPLIFIER);
PoolReadGuard pg(&tempSyrlinksPowerAmplifier, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempSyrlinksPowerAmplifier, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read syrlinks power amplifier temperature" sif::warning << "ThermalController: Failed to read syrlinks power amplifier temperature"
@ -755,8 +738,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempSyrlinksBasebandBoard =
lp_var_t<float>(objects::SYRLINKS_HANDLER, syrlinks::TEMP_BASEBAND_BOARD);
PoolReadGuard pg(&tempSyrlinksBasebandBoard, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempSyrlinksBasebandBoard, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read syrlinks baseband board temperature" sif::warning << "ThermalController: Failed to read syrlinks baseband board temperature"
@ -770,7 +751,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<int16_t> tempMgt = lp_var_t<int16_t>(objects::IMTQ_HANDLER, imtq::MCU_TEMPERATURE);
PoolReadGuard pg(&tempMgt, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempMgt, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read MGT temperature" << std::endl; sif::warning << "ThermalController: Failed to read MGT temperature" << std::endl;
@ -783,8 +763,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_vec_t<float, 3> tempAcu =
lp_vec_t<float, 3>(objects::ACU_HANDLER, ACU::pool::ACU_TEMPERATURES);
PoolReadGuard pg(&tempAcu, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempAcu, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read ACU temperatures" << std::endl; sif::warning << "ThermalController: Failed to read ACU temperatures" << std::endl;
@ -799,7 +777,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempPdu1 = lp_var_t<float>(objects::PDU1_HANDLER, PDU::pool::PDU_TEMPERATURE);
PoolReadGuard pg(&tempPdu1, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempPdu1, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read PDU1 temperature" << std::endl; sif::warning << "ThermalController: Failed to read PDU1 temperature" << std::endl;
@ -812,7 +789,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempPdu2 = lp_var_t<float>(objects::PDU2_HANDLER, PDU::pool::PDU_TEMPERATURE);
PoolReadGuard pg(&tempPdu2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempPdu2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read PDU2 temperature" << std::endl; sif::warning << "ThermalController: Failed to read PDU2 temperature" << std::endl;
@ -825,8 +801,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> temp1P60dock =
lp_var_t<float>(objects::P60DOCK_HANDLER, P60Dock::pool::P60DOCK_TEMPERATURE_1);
PoolReadGuard pg(&temp1P60dock, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&temp1P60dock, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read P60 dock temperature 1" << std::endl; sif::warning << "ThermalController: Failed to read P60 dock temperature 1" << std::endl;
@ -839,8 +813,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> temp2P60dock =
lp_var_t<float>(objects::P60DOCK_HANDLER, P60Dock::pool::P60DOCK_TEMPERATURE_2);
PoolReadGuard pg(&temp2P60dock, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&temp2P60dock, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read P60 dock temperature 2" << std::endl; sif::warning << "ThermalController: Failed to read P60 dock temperature 2" << std::endl;
@ -853,8 +825,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempGyro0 =
lp_var_t<float>(objects::GYRO_0_ADIS_HANDLER, adis1650x::TEMPERATURE);
PoolReadGuard pg(&tempGyro0, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempGyro0, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read gyro 0 temperature" << std::endl; sif::warning << "ThermalController: Failed to read gyro 0 temperature" << std::endl;
@ -867,7 +837,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempGyro1 = lp_var_t<float>(objects::GYRO_1_L3G_HANDLER, l3gd20h::TEMPERATURE);
PoolReadGuard pg(&tempGyro1, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempGyro1, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read gyro 1 temperature" << std::endl; sif::warning << "ThermalController: Failed to read gyro 1 temperature" << std::endl;
@ -880,8 +849,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempGyro2 =
lp_var_t<float>(objects::GYRO_2_ADIS_HANDLER, adis1650x::TEMPERATURE);
PoolReadGuard pg(&tempGyro2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempGyro2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read gyro 2 temperature" << std::endl; sif::warning << "ThermalController: Failed to read gyro 2 temperature" << std::endl;
@ -894,7 +861,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempGyro3 = lp_var_t<float>(objects::GYRO_3_L3G_HANDLER, l3gd20h::TEMPERATURE);
PoolReadGuard pg(&tempGyro3, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempGyro3, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read gyro 3 temperature" << std::endl; sif::warning << "ThermalController: Failed to read gyro 3 temperature" << std::endl;
@ -907,8 +873,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempMgm0 =
lp_var_t<float>(objects::MGM_0_LIS3_HANDLER, mgmLis3::TEMPERATURE_CELCIUS);
PoolReadGuard pg(&tempMgm0, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempMgm0, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read MGM 0 temperature" << std::endl; sif::warning << "ThermalController: Failed to read MGM 0 temperature" << std::endl;
@ -921,8 +885,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempMgm2 =
lp_var_t<float>(objects::MGM_2_LIS3_HANDLER, mgmLis3::TEMPERATURE_CELCIUS);
PoolReadGuard pg(&tempMgm2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempMgm2, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read MGM 2 temperature" << std::endl; sif::warning << "ThermalController: Failed to read MGM 2 temperature" << std::endl;
@ -935,7 +897,6 @@ void ThermalController::copyDevices() {
} }
{ {
lp_var_t<float> tempAdcPayloadPcdu = lp_var_t<float>(objects::PLPCDU_HANDLER, plpcdu::TEMP);
PoolReadGuard pg(&tempAdcPayloadPcdu, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT); PoolReadGuard pg(&tempAdcPayloadPcdu, MutexIF::TimeoutType::WAITING, MUTEX_TIMEOUT);
if (pg.getReadResult() != returnvalue::OK) { if (pg.getReadResult() != returnvalue::OK) {
sif::warning << "ThermalController: Failed to read payload PCDU ADC temperature" << std::endl; sif::warning << "ThermalController: Failed to read payload PCDU ADC temperature" << std::endl;

View File

@ -1,12 +1,22 @@
#ifndef MISSION_CONTROLLER_THERMALCONTROLLER_H_ #ifndef MISSION_CONTROLLER_THERMALCONTROLLER_H_
#define MISSION_CONTROLLER_THERMALCONTROLLER_H_ #define MISSION_CONTROLLER_THERMALCONTROLLER_H_
#include <bsp_q7s/core/CoreDefinitions.h>
#include <fsfw/controller/ExtendedControllerBase.h> #include <fsfw/controller/ExtendedControllerBase.h>
#include <fsfw/devicehandlers/DeviceHandlerThermalSet.h> #include <fsfw/devicehandlers/DeviceHandlerThermalSet.h>
#include <fsfw/timemanager/Countdown.h> #include <fsfw/timemanager/Countdown.h>
#include <fsfw_hal/devicehandlers/devicedefinitions/gyroL3gHelpers.h>
#include <fsfw_hal/devicehandlers/devicedefinitions/mgmLis3Helpers.h>
#include <linux/devices/devicedefinitions/StarTrackerDefinitions.h>
#include <mission/controller/controllerdefinitions/ThermalControllerDefinitions.h> #include <mission/controller/controllerdefinitions/ThermalControllerDefinitions.h>
#include <mission/devices/devicedefinitions/BpxBatteryDefinitions.h>
#include <mission/devices/devicedefinitions/Max31865Definitions.h> #include <mission/devices/devicedefinitions/Max31865Definitions.h>
#include <mission/devices/devicedefinitions/SyrlinksDefinitions.h>
#include <mission/devices/devicedefinitions/Tmp1075Definitions.h> #include <mission/devices/devicedefinitions/Tmp1075Definitions.h>
#include <mission/devices/devicedefinitions/gyroAdisHelpers.h>
#include <mission/devices/devicedefinitions/imtqHelpers.h>
#include <mission/devices/devicedefinitions/payloadPcduDefinitions.h>
#include <mission/devices/devicedefinitions/rwHelpers.h>
#include <mission/devices/devicedefinitions/susMax1227Helpers.h> #include <mission/devices/devicedefinitions/susMax1227Helpers.h>
#include <list> #include <list>
@ -125,6 +135,44 @@ class ThermalController : public ExtendedControllerBase {
susMax1227::SusDataset susSet10; susMax1227::SusDataset susSet10;
susMax1227::SusDataset susSet11; susMax1227::SusDataset susSet11;
lp_var_t<float> tempQ7s = lp_var_t<float>(objects::CORE_CONTROLLER, core::PoolIds::TEMPERATURE);
lp_var_t<int16_t> battTemp1 =
lp_var_t<int16_t>(objects::BPX_BATT_HANDLER, BpxBattery::BATT_TEMP_1);
lp_var_t<int16_t> battTemp2 =
lp_var_t<int16_t>(objects::BPX_BATT_HANDLER, BpxBattery::BATT_TEMP_2);
lp_var_t<int16_t> battTemp3 =
lp_var_t<int16_t>(objects::BPX_BATT_HANDLER, BpxBattery::BATT_TEMP_3);
lp_var_t<int16_t> battTemp4 =
lp_var_t<int16_t>(objects::BPX_BATT_HANDLER, BpxBattery::BATT_TEMP_4);
lp_var_t<int32_t> tempRw1 = lp_var_t<int32_t>(objects::RW1, rws::TEMPERATURE_C);
lp_var_t<int32_t> tempRw2 = lp_var_t<int32_t>(objects::RW2, rws::TEMPERATURE_C);
lp_var_t<int32_t> tempRw3 = lp_var_t<int32_t>(objects::RW3, rws::TEMPERATURE_C);
lp_var_t<int32_t> tempRw4 = lp_var_t<int32_t>(objects::RW4, rws::TEMPERATURE_C);
lp_var_t<float> tempStartracker =
lp_var_t<float>(objects::STAR_TRACKER, startracker::MCU_TEMPERATURE);
lp_var_t<float> tempSyrlinksPowerAmplifier =
lp_var_t<float>(objects::SYRLINKS_HANDLER, syrlinks::TEMP_POWER_AMPLIFIER);
lp_var_t<float> tempSyrlinksBasebandBoard =
lp_var_t<float>(objects::SYRLINKS_HANDLER, syrlinks::TEMP_BASEBAND_BOARD);
lp_var_t<int16_t> tempMgt = lp_var_t<int16_t>(objects::IMTQ_HANDLER, imtq::MCU_TEMPERATURE);
lp_vec_t<float, 3> tempAcu =
lp_vec_t<float, 3>(objects::ACU_HANDLER, ACU::pool::ACU_TEMPERATURES);
lp_var_t<float> tempPdu1 = lp_var_t<float>(objects::PDU1_HANDLER, PDU::pool::PDU_TEMPERATURE);
lp_var_t<float> tempPdu2 = lp_var_t<float>(objects::PDU2_HANDLER, PDU::pool::PDU_TEMPERATURE);
lp_var_t<float> temp1P60dock =
lp_var_t<float>(objects::P60DOCK_HANDLER, P60Dock::pool::P60DOCK_TEMPERATURE_1);
lp_var_t<float> temp2P60dock =
lp_var_t<float>(objects::P60DOCK_HANDLER, P60Dock::pool::P60DOCK_TEMPERATURE_2);
lp_var_t<float> tempGyro0 = lp_var_t<float>(objects::GYRO_0_ADIS_HANDLER, adis1650x::TEMPERATURE);
lp_var_t<float> tempGyro1 = lp_var_t<float>(objects::GYRO_1_L3G_HANDLER, l3gd20h::TEMPERATURE);
lp_var_t<float> tempGyro2 = lp_var_t<float>(objects::GYRO_2_ADIS_HANDLER, adis1650x::TEMPERATURE);
lp_var_t<float> tempGyro3 = lp_var_t<float>(objects::GYRO_3_L3G_HANDLER, l3gd20h::TEMPERATURE);
lp_var_t<float> tempMgm0 =
lp_var_t<float>(objects::MGM_0_LIS3_HANDLER, mgmLis3::TEMPERATURE_CELCIUS);
lp_var_t<float> tempMgm2 =
lp_var_t<float>(objects::MGM_2_LIS3_HANDLER, mgmLis3::TEMPERATURE_CELCIUS);
lp_var_t<float> tempAdcPayloadPcdu = lp_var_t<float>(objects::PLPCDU_HANDLER, plpcdu::TEMP);
// TempLimits // TempLimits
TempLimits acsBoardLimits = TempLimits(-40.0, -40.0, 80.0, 85.0, 85.0); TempLimits acsBoardLimits = TempLimits(-40.0, -40.0, 80.0, 85.0, 85.0);
TempLimits mgtLimits = TempLimits(-40.0, -40.0, 65.0, 70.0, 70.0); TempLimits mgtLimits = TempLimits(-40.0, -40.0, 65.0, 70.0, 70.0);

View File

@ -39,7 +39,6 @@ ReturnValue_t CcsdsIpCoreHandler::performOperation(uint8_t operationCode) {
} }
ReturnValue_t CcsdsIpCoreHandler::initialize() { ReturnValue_t CcsdsIpCoreHandler::initialize() {
AcceptsTelecommandsIF* tcDistributor = AcceptsTelecommandsIF* tcDistributor =
ObjectManager::instance()->get<AcceptsTelecommandsIF>(tcDestination); ObjectManager::instance()->get<AcceptsTelecommandsIF>(tcDestination);
if (tcDistributor == nullptr) { if (tcDistributor == nullptr) {