this snippet should recognize faulty sensors #592
@ -1,3 +1 @@
|
|||||||
|
target_sources(${LIB_EIVE_MISSION} PRIVATE CfdpHandler.cpp)
|
||||||
target_sources(
|
|
||||||
${LIB_EIVE_MISSION} PRIVATE CfdpHandler.cpp)
|
|
||||||
|
@ -1,5 +1,4 @@
|
|||||||
#include <fsfw/cfdp/CfdpDistributor.h>
|
#include <fsfw/cfdp/CfdpDistributor.h>
|
||||||
#include <mission/cfdp/CfdpHandler.h>
|
|
||||||
#include <fsfw/cfdp/handler/RemoteConfigTableIF.h>
|
#include <fsfw/cfdp/handler/RemoteConfigTableIF.h>
|
||||||
#include <fsfw/controller/ControllerBase.h>
|
#include <fsfw/controller/ControllerBase.h>
|
||||||
#include <fsfw/controller/ExtendedControllerBase.h>
|
#include <fsfw/controller/ExtendedControllerBase.h>
|
||||||
@ -23,6 +22,7 @@
|
|||||||
#include <fsfw/tcdistribution/PusDistributor.h>
|
#include <fsfw/tcdistribution/PusDistributor.h>
|
||||||
#include <fsfw/timemanager/CdsShortTimeStamper.h>
|
#include <fsfw/timemanager/CdsShortTimeStamper.h>
|
||||||
#include <fsfw_hal/host/HostFilesystem.h>
|
#include <fsfw_hal/host/HostFilesystem.h>
|
||||||
|
#include <mission/cfdp/CfdpHandler.h>
|
||||||
#include <mission/controller/ThermalController.h>
|
#include <mission/controller/ThermalController.h>
|
||||||
#include <mission/genericFactory.h>
|
#include <mission/genericFactory.h>
|
||||||
#include <mission/persistentTmStoreDefs.h>
|
#include <mission/persistentTmStoreDefs.h>
|
||||||
|
@ -1,6 +1,8 @@
|
|||||||
#include <fsfw/datapool/PoolReadGuard.h>
|
#include <fsfw/datapool/PoolReadGuard.h>
|
||||||
#include <mission/tcs/Max31865EiveHandler.h>
|
#include <mission/tcs/Max31865EiveHandler.h>
|
||||||
|
|
||||||
|
#include "fsfw/thermal/tcsDefinitions.h"
|
||||||
|
|
||||||
Max31865EiveHandler::Max31865EiveHandler(object_id_t objectId, object_id_t comIF,
|
Max31865EiveHandler::Max31865EiveHandler(object_id_t objectId, object_id_t comIF,
|
||||||
CookieIF* comCookie)
|
CookieIF* comCookie)
|
||||||
: DeviceHandlerBase(objectId, comIF, comCookie, nullptr),
|
: DeviceHandlerBase(objectId, comIF, comCookie, nullptr),
|
||||||
@ -152,6 +154,15 @@ ReturnValue_t Max31865EiveHandler::interpretDeviceReply(DeviceCommandId_t id,
|
|||||||
transitionOk = true;
|
transitionOk = true;
|
||||||
return returnvalue::OK;
|
return returnvalue::OK;
|
||||||
}
|
}
|
||||||
|
// If the 15 received bits are all ones, this is considered a case where the device does not
|
||||||
|
// work because it does not drive the MISO line. This can happens if the sensor is broken
|
||||||
|
// or off.
|
||||||
|
if (exchangeStruct.adcCode == 0x7fff) {
|
||||||
|
PoolReadGuard pg(&sensorDataset);
|
||||||
|
sensorDataset.temperatureCelcius.setValid(false);
|
||||||
|
sensorDataset.temperatureCelcius = thermal::INVALID_TEMPERATURE;
|
||||||
|
return returnvalue::FAILED;
|
||||||
|
}
|
||||||
|
|
||||||
// Calculate resistance
|
// Calculate resistance
|
||||||
float rtdValue = exchangeStruct.adcCode * EiveMax31855::RTD_RREF_PT1000 / INT16_MAX;
|
float rtdValue = exchangeStruct.adcCode * EiveMax31855::RTD_RREF_PT1000 / INT16_MAX;
|
||||||
|