TCS heater upper burn limit #732
@ -15,7 +15,7 @@ TemperatureSensorInserter::TemperatureSensorInserter(
|
||||
tmp1075DummyMap(std::move(tempTmpSensorDummies_)) {}
|
||||
|
||||
ReturnValue_t TemperatureSensorInserter::initialize() {
|
||||
testCase = TestCase::COLD_PLOC_STAYS_COLD;
|
||||
testCase = TestCase::COLD_CAMERA_STAYS_COLD;
|
||||
return returnvalue::OK;
|
||||
}
|
||||
|
||||
@ -133,6 +133,14 @@ ReturnValue_t TemperatureSensorInserter::performOperation(uint8_t opCode) {
|
||||
sif::debug << "Setting cold PLOC temperature" << std::endl;
|
||||
max31865DummyMap[objects::RTD_0_IC3_PLOC_HEATSPREADER]->setTemperature(-40, true);
|
||||
}
|
||||
break;
|
||||
}
|
||||
case (TestCase::COLD_CAMERA_STAYS_COLD): {
|
||||
if (cycles == 15) {
|
||||
sif::debug << "Setting cold PLOC temperature" << std::endl;
|
||||
max31865DummyMap[objects::RTD_2_IC5_4K_CAMERA]->setTemperature(-40, true);
|
||||
}
|
||||
break;
|
||||
}
|
||||
}
|
||||
cycles++;
|
||||
|
@ -33,7 +33,8 @@ class TemperatureSensorInserter : public ExecutableObjectIF, public SystemObject
|
||||
COLD_STR_CONSECUTIVE = 5,
|
||||
COLD_CAMERA = 6,
|
||||
COLD_PLOC_CONSECUTIVE = 7,
|
||||
COLD_PLOC_STAYS_COLD = 8
|
||||
COLD_PLOC_STAYS_COLD = 8,
|
||||
COLD_CAMERA_STAYS_COLD = 9
|
||||
};
|
||||
int iteration = 0;
|
||||
uint32_t cycles = 0;
|
||||
|
@ -1798,8 +1798,6 @@ void ThermalController::heaterMaxDurationControl(const HeaterSwitchStates& curre
|
||||
// The heater might still be one for some thermal components, so cross-check
|
||||
// those components
|
||||
crossCheckHeaterStateOfComponentsWhenHeaterGoesOff(static_cast<heater::Switch>(i));
|
||||
} else if (currentHeaterStates[i] == HeaterHandler::SwitchState::OFF) {
|
||||
heaterStates[i].heaterOnPeriod.resetTimer();
|
||||
}
|
||||
}
|
||||
}
|
||||
|
@ -111,7 +111,7 @@ class ThermalController : public ExtendedControllerBase {
|
||||
// 1 hour
|
||||
static constexpr uint32_t DEFAULT_MAX_HEATER_ON_DURATION_MS = 60 * 60 * 1000;
|
||||
|
||||
static constexpr uint32_t MAX_HEATER_ON_DURATIONS_MS[8] = {// PLOC PROC board
|
||||
60 * 1000,
|
||||
DEFAULT_MAX_HEATER_ON_DURATION_MS,
|
||||
// PCDU PDU
|
||||
DEFAULT_MAX_HEATER_ON_DURATION_MS,
|
||||
// ACS Board
|
||||
|
Loading…
Reference in New Issue
Block a user
maybe we should change this to being a parameter someday
If all the changes fix the current heater issue, this mechanism will hopefully never have be used at all.. at least that is what I am hoping.