eive-obsw/mission/system/objects/ComSubsystem.h
Robin Mueller a190d99f6d
All checks were successful
EIVE/eive-obsw/pipeline/pr-develop This commit looks good
auto-formatter
2023-02-22 19:45:41 +01:00

81 lines
2.6 KiB
C++

#ifndef MISSION_SYSTEM_COMSUBSYSTEM_H_
#define MISSION_SYSTEM_COMSUBSYSTEM_H_
#include <fsfw/events/EventMessage.h>
#include <fsfw/parameters/HasParametersIF.h>
#include <fsfw/parameters/ParameterHelper.h>
#include <fsfw/subsystem/Subsystem.h>
#include "mission/comDefs.h"
class ComSubsystem : public Subsystem, public ReceivesParameterMessagesIF {
public:
/**
* @brief Constructor
*
* @param setObjectId
* @param maxNumberOfSequences
* @param maxNumberOfTables
* @param transmitterTimeout Maximum time the transmitter of the syrlinks
* will be
* enabled
*/
ComSubsystem(object_id_t setObjectId, uint32_t maxNumberOfSequences, uint32_t maxNumberOfTables,
uint32_t transmitterTimeout);
virtual ~ComSubsystem() = default;
MessageQueueId_t getCommandQueue() const override;
ReturnValue_t getParameter(uint8_t domainId, uint8_t uniqueIdentifier,
ParameterWrapper *parameterWrapper, const ParameterWrapper *newValues,
uint16_t startAtIndex) override;
virtual void performChildOperation() override;
private:
static const Mode_t INITIAL_MODE = 0;
ReturnValue_t handleCommandMessage(CommandMessage *message) override;
ReturnValue_t initialize() override;
void startTransition(Mode_t mode, Submode_t submode) override;
void readEventQueue();
void handleEventMessage(EventMessage *eventMessage);
void handleBitLockEvent();
void handleCarrierLockEvent();
void checkTransmitterCountdown();
/**
* @brief Enables transmitter in low rate mode
*/
void startRxAndTxLowRateSeq();
/**
* @brief Returns true if mode is a mode where the transmitter is on
*/
bool isTxMode(Mode_t mode);
uint8_t datarateCfg = static_cast<uint8_t>(com::Datarate::LOW_RATE_MODULATION_BPSK);
// Maximum time after which the transmitter will be turned of. This is a
// protection mechanism due prevent the syrlinks from overheating
uint32_t transmitterTimeout = 0;
ParameterHelper paramHelper;
MessageQueueIF *eventQueue = nullptr;
bool enableTxWhenCarrierLock = false;
// Countdown will be started as soon as the transmitter was enabled
Countdown transmitterCountdown;
// Transmitter countdown only active when sysrlinks transmitter is on (modes:
// rx and tx low rate, rx and tx high rate, rx and tx default rate)
bool countdownActive = false;
// True when bit lock occurred while COM subsystem is in a transition. This
// variable is used to remember the bit lock and execute the default rate
// sequence after the active transition has been completed
bool rememberBitLock = false;
};
#endif /* MISSION_SYSTEM_COMSUBSYSTEM_H_ */