eive-obsw/mission/devices/PlocHandler.h
2021-03-29 14:37:52 +02:00

78 lines
2.8 KiB
C++

#ifndef MISSION_DEVICES_PLOCHANDLER_H_
#define MISSION_DEVICES_PLOCHANDLER_H_
#include <fsfw/devicehandlers/DeviceHandlerBase.h>
#include <mission/devices/devicedefinitions/PlocHandlerDefinitions.h>
#include <string.h>
/**
* @brief This is the device handler for the ISIS Magnetorquer iMTQ.
*
* @author J. Meier
*/
class PlocHandler: public DeviceHandlerBase {
public:
PlocHandler(object_id_t objectId, object_id_t comIF, CookieIF * comCookie);
virtual ~PlocHandler();
/**
* @brief Sets mode to MODE_NORMAL. Can be used for debugging.
*/
void setModeNormal();
protected:
void doStartUp() override;
void doShutDown() override;
ReturnValue_t buildNormalDeviceCommand(DeviceCommandId_t * id) override;
ReturnValue_t buildTransitionDeviceCommand(DeviceCommandId_t * id) override;
void fillCommandAndReplyMap() override;
ReturnValue_t buildCommandFromCommand(DeviceCommandId_t deviceCommand,
const uint8_t * commandData,size_t commandDataLen) override;
ReturnValue_t scanForReply(const uint8_t *start, size_t remainingSize,
DeviceCommandId_t *foundId, size_t *foundLen) override;
ReturnValue_t interpretDeviceReply(DeviceCommandId_t id,
const uint8_t *packet) override;
void setNormalDatapoolEntriesInvalid() override;
uint32_t getTransitionDelayMs(Mode_t modeFrom, Mode_t modeTo) override;
ReturnValue_t initializeLocalDataPool(localpool::DataPool& localDataPoolMap,
LocalDataPoolManager& poolManager) override;
private:
static const uint8_t INTERFACE_ID = CLASS_ID::IMTQ_HANDLER;
static const ReturnValue_t INVALID_COMMAND_CODE = MAKE_RETURN_CODE(0xA0);
static const ReturnValue_t PARAMETER_MISSING = MAKE_RETURN_CODE(0xA1);
static const ReturnValue_t PARAMETER_INVALID = MAKE_RETURN_CODE(0xA2);
static const ReturnValue_t CC_UNAVAILABLE = MAKE_RETURN_CODE(0xA3);
static const ReturnValue_t INTERNAL_PROCESSING_ERROR = MAKE_RETURN_CODE(0xA4);
static const ReturnValue_t REJECTED_WITHOUT_REASON = MAKE_RETURN_CODE(0xA5);
static const ReturnValue_t CMD_ERR_UNKNOWN = MAKE_RETURN_CODE(0xA6);
IMTQ::EngHkDataset engHkDataset;
uint8_t commandBuffer[IMTQ::MAX_COMMAND_SIZE];
/**
* @brief Each reply contains a status byte giving information about a request. This function
* parses this byte and returns the associated failure message.
*
* @param packet Pointer to the received message containing the status byte.
*
* @return The return code derived from the received status byte.
*/
ReturnValue_t parseStatusByte(const uint8_t* packet);
/**
* @brief This function fills the engineering housekeeping dataset with the received data.
* @param packet Pointer to the received data.
*
*/
void fillEngHkDataset(const uint8_t* packet);
};
#endif /* MISSION_DEVICES_PLOCHANDLER_H_ */