additional pl pcdu commands
This commit is contained in:
parent
37c1a68da1
commit
2ef8f5a32e
@ -92,17 +92,22 @@ def add_core_controller_definitions(cmd_dict: ServiceOpCodeDictT):
|
|||||||
|
|
||||||
def add_pl_pcdu_cmds(cmd_dict: ServiceOpCodeDictT):
|
def add_pl_pcdu_cmds(cmd_dict: ServiceOpCodeDictT):
|
||||||
from pus_tc.plpcdu import OpCodes
|
from pus_tc.plpcdu import OpCodes
|
||||||
|
|
||||||
op_code_dict = dict()
|
op_code_dict = dict()
|
||||||
add_op_code_entry(
|
add_op_code_entry(
|
||||||
op_code_dict=op_code_dict,
|
op_code_dict=op_code_dict,
|
||||||
keys=OpCodes.SWITCH_ADC_ON,
|
keys=OpCodes.SWITCH_ON,
|
||||||
info="Switch PL PCDU ADC on",
|
info="Switch PL PCDU on"
|
||||||
)
|
)
|
||||||
add_op_code_entry(
|
add_op_code_entry(
|
||||||
op_code_dict=op_code_dict,
|
op_code_dict=op_code_dict,
|
||||||
keys=OpCodes.SWITCH_ALL_ON,
|
keys=OpCodes.SWITCH_ADC_NORMAL,
|
||||||
info="Switch all PL PCDU modules on",
|
info="Switch PL PCDU ADC normal, submode ADC ON"
|
||||||
|
)
|
||||||
|
add_op_code_entry(
|
||||||
|
op_code_dict=op_code_dict,
|
||||||
|
keys=OpCodes.SWITCH_ALL_NORMAL,
|
||||||
|
info="Switch all PL PCDU modules normal, submode ALL ON",
|
||||||
|
options={OpCodeDictKeys.ENTER_LISTENER_MODE: True}
|
||||||
)
|
)
|
||||||
add_op_code_entry(
|
add_op_code_entry(
|
||||||
op_code_dict=op_code_dict,
|
op_code_dict=op_code_dict,
|
||||||
|
@ -17,19 +17,20 @@ LOGGER = get_console_logger()
|
|||||||
|
|
||||||
|
|
||||||
class OpCodes:
|
class OpCodes:
|
||||||
SWITCH_ADC_ON = ["0", "switch-adc-on"]
|
SWITCH_ON = ["0", "switch-adc-on"]
|
||||||
SWITCH_ALL_ON = ["1", "switch-all-on"]
|
SWITCH_ADC_NORMAL = ["1", "switch-adc-normal"]
|
||||||
UPDATE_DRO_TO_X8_WAIT = ["2", "dro-to-x8-wait"]
|
SWITCH_ALL_NORMAL = ["2", "switch-all-normal"]
|
||||||
UPDATE_X8_TO_TX_WAIT_TIME = ["3", "x8-to-tx-wait"]
|
UPDATE_DRO_TO_X8_WAIT = ["3", "dro-to-x8-wait"]
|
||||||
UPDATE_TX_TO_MPA_WAIT_TIME = ["4", "tx-to-mpa-wait"]
|
UPDATE_X8_TO_TX_WAIT_TIME = ["4", "x8-to-tx-wait"]
|
||||||
UPDATE_MPA_TO_HPA_WAIT_TIME = ["5", "mpa-to-hpa-wait"]
|
UPDATE_TX_TO_MPA_WAIT_TIME = ["5", "tx-to-mpa-wait"]
|
||||||
|
UPDATE_MPA_TO_HPA_WAIT_TIME = ["6", "mpa-to-hpa-wait"]
|
||||||
|
|
||||||
INJECT_SSR_TO_DRO_FAILURE = ["6", "inject-ssr-dro-fault"]
|
INJECT_SSR_TO_DRO_FAILURE = ["10", "inject-ssr-dro-fault"]
|
||||||
INJECT_DRO_TO_X8_FAILURE = ["7", "inject-dro-x8-fault"]
|
INJECT_DRO_TO_X8_FAILURE = ["11", "inject-dro-x8-fault"]
|
||||||
INJECT_X8_TO_TX_FAILURE = ["8", "inject-x8-tx-fault"]
|
INJECT_X8_TO_TX_FAILURE = ["12", "inject-x8-tx-fault"]
|
||||||
INJECT_TX_TO_MPA_FAILURE = ["9", "inject-tx-mpa-fault"]
|
INJECT_TX_TO_MPA_FAILURE = ["13", "inject-tx-mpa-fault"]
|
||||||
INJECT_MPA_TO_HPA_FAILURE = ["10", "inject-mpa-hpa-fault"]
|
INJECT_MPA_TO_HPA_FAILURE = ["14", "inject-mpa-hpa-fault"]
|
||||||
INJECT_ALL_ON_FAILURE = ["11", "inject-all-on-fault"]
|
INJECT_ALL_ON_FAILURE = ["15", "inject-all-on-fault"]
|
||||||
|
|
||||||
|
|
||||||
class Submodes(enum.IntEnum):
|
class Submodes(enum.IntEnum):
|
||||||
@ -76,8 +77,17 @@ class ParamIds(enum.IntEnum):
|
|||||||
|
|
||||||
|
|
||||||
def pack_pl_pcdu_commands(tc_queue: TcQueueT, op_code: str):
|
def pack_pl_pcdu_commands(tc_queue: TcQueueT, op_code: str):
|
||||||
if op_code in OpCodes.SWITCH_ADC_ON:
|
if op_code in OpCodes.SWITCH_ON:
|
||||||
tc_queue.appendleft((QueueCommands.PRINT, "Switching PL PCDU ADC module on"))
|
tc_queue.appendleft((QueueCommands.PRINT, "Switching PL PCDU ADC module on"))
|
||||||
|
mode_data = pack_mode_data(
|
||||||
|
object_id=PL_PCDU_ID, mode=Modes.ON, submode=Submodes.ADC_ON
|
||||||
|
)
|
||||||
|
mode_cmd = PusTelecommand(
|
||||||
|
service=200, subservice=Subservices.SWITCH_MODE, app_data=mode_data
|
||||||
|
)
|
||||||
|
tc_queue.appendleft(mode_cmd.pack_command_tuple())
|
||||||
|
if op_code in OpCodes.SWITCH_ADC_NORMAL:
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "Switching PL PCDU ADC module normal, submode ADC ON"))
|
||||||
mode_data = pack_mode_data(
|
mode_data = pack_mode_data(
|
||||||
object_id=PL_PCDU_ID, mode=Modes.NORMAL, submode=Submodes.ADC_ON
|
object_id=PL_PCDU_ID, mode=Modes.NORMAL, submode=Submodes.ADC_ON
|
||||||
)
|
)
|
||||||
@ -85,8 +95,8 @@ def pack_pl_pcdu_commands(tc_queue: TcQueueT, op_code: str):
|
|||||||
service=200, subservice=Subservices.SWITCH_MODE, app_data=mode_data
|
service=200, subservice=Subservices.SWITCH_MODE, app_data=mode_data
|
||||||
)
|
)
|
||||||
tc_queue.appendleft(mode_cmd.pack_command_tuple())
|
tc_queue.appendleft(mode_cmd.pack_command_tuple())
|
||||||
if op_code in OpCodes.SWITCH_ALL_ON:
|
if op_code in OpCodes.SWITCH_ALL_NORMAL:
|
||||||
tc_queue.appendleft((QueueCommands.PRINT, "Switching all PL PCDU modules on"))
|
tc_queue.appendleft((QueueCommands.PRINT, "Switching all PL PCDU modules normal, submode ALL ON"))
|
||||||
mode_data = pack_mode_data(
|
mode_data = pack_mode_data(
|
||||||
object_id=PL_PCDU_ID, mode=Modes.NORMAL, submode=Submodes.ALL_ON
|
object_id=PL_PCDU_ID, mode=Modes.NORMAL, submode=Submodes.ALL_ON
|
||||||
)
|
)
|
||||||
|
2
tmtccmd
2
tmtccmd
@ -1 +1 @@
|
|||||||
Subproject commit 81a88435a52c8115a9f4349e307b252ebb2ebb85
|
Subproject commit 02440987a06395803e8e679dd5c491eb8578a8df
|
Loading…
Reference in New Issue
Block a user