turn on stack 3V3
This commit is contained in:
parent
84485a245b
commit
5574fe91c7
@ -1,5 +1,5 @@
|
||||
<component name="ProjectRunConfigurationManager">
|
||||
<configuration default="false" name="P60 Dock Test UDP" type="PythonConfigurationType" factoryName="Python" folderName="Devices">
|
||||
<configuration default="false" name="P60 Dock Commanding" type="PythonConfigurationType" factoryName="Python" folderName="Devices">
|
||||
<module name="tmtc" />
|
||||
<option name="INTERPRETER_OPTIONS" value="" />
|
||||
<option name="PARENT_ENVS" value="true" />
|
@ -1,5 +1,5 @@
|
||||
<component name="ProjectRunConfigurationManager">
|
||||
<configuration default="false" name="PDU1 Test" type="PythonConfigurationType" factoryName="Python" folderName="Devices">
|
||||
<configuration default="false" name="PDU1 Commanding" type="PythonConfigurationType" factoryName="Python" folderName="Devices">
|
||||
<module name="tmtc" />
|
||||
<option name="INTERPRETER_OPTIONS" value="" />
|
||||
<option name="PARENT_ENVS" value="true" />
|
@ -1,5 +1,5 @@
|
||||
<component name="ProjectRunConfigurationManager">
|
||||
<configuration default="false" name="PDU2 Test UDP" type="PythonConfigurationType" factoryName="Python" folderName="Devices">
|
||||
<configuration default="false" name="PDU2 Commanding" type="PythonConfigurationType" factoryName="Python" folderName="Devices">
|
||||
<module name="tmtc" />
|
||||
<option name="INTERPRETER_OPTIONS" value="" />
|
||||
<option name="PARENT_ENVS" value="true" />
|
@ -47,6 +47,8 @@ class EiveHookObject(TmTcHookBase):
|
||||
|
||||
op_code_dict_srv_p60 = {
|
||||
"0": ("P60 Tests", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"1": ("P60 Dock: Turn stack 3V3 on", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"2": ("P60 Dock: Turn stack 3V3 off", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
}
|
||||
service_p60_tuple = ("P60 Device", op_code_dict_srv_p60)
|
||||
|
||||
@ -64,6 +66,8 @@ class EiveHookObject(TmTcHookBase):
|
||||
|
||||
op_code_dict_srv_pdu2 = {
|
||||
"0": ("PDU2 Tests", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"1": ("PDU1: Turn ACS Side B on", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"2": ("PDU1: Turn ACS Side B off", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
}
|
||||
service_pdu2_tuple = ("PDU2 Device", op_code_dict_srv_pdu2)
|
||||
|
||||
|
@ -33,10 +33,19 @@ class P60DockTestProcedure:
|
||||
|
||||
|
||||
class P60DockConfigTable:
|
||||
out_en_0 = TableEntry(bytearray([0x00, 0x68]), TableEntry.uint8_size) # ACU
|
||||
out_en_1 = TableEntry(bytearray([0x00, 0x69]), TableEntry.uint8_size) # PDU1
|
||||
out_en_2 = TableEntry(bytearray([0x00, 0x6A]), TableEntry.uint8_size)
|
||||
out_en_3 = TableEntry(bytearray([0x00, 0x6B]), TableEntry.uint8_size) # PDU2
|
||||
out_en_0 = TableEntry(bytearray([0x00, 0x68]), TableEntry.uint8_size) # ACU VCC
|
||||
out_en_1 = TableEntry(bytearray([0x00, 0x69]), TableEntry.uint8_size) # PDU1 VCC
|
||||
out_en_2 = TableEntry(bytearray([0x00, 0x6A]), TableEntry.uint8_size) # unused
|
||||
out_en_3 = TableEntry(bytearray([0x00, 0x6B]), TableEntry.uint8_size) # PDU2 VCC
|
||||
out_en_4 = TableEntry(bytearray([0x00, 0x6C]), TableEntry.uint8_size) # ACU VBAT
|
||||
out_en_5 = TableEntry(bytearray([0x00, 0x6D]), TableEntry.uint8_size) # unused
|
||||
out_en_6 = TableEntry(bytearray([0x00, 0x6E]), TableEntry.uint8_size) # PDU1 VBAT
|
||||
out_en_7 = TableEntry(bytearray([0x00, 0x6F]), TableEntry.uint8_size) # PDU2 VBAT
|
||||
out_en_8 = TableEntry(bytearray([0x00, 0x70]), TableEntry.uint8_size) # Stack VBAT
|
||||
out_en_9 = TableEntry(bytearray([0x00, 0x71]), TableEntry.uint8_size) # Stack 3V3
|
||||
out_en_10 = TableEntry(bytearray([0x00, 0x72]), TableEntry.uint8_size) # Stack 5V
|
||||
out_en_11 = TableEntry(bytearray([0x00, 0x73]), TableEntry.uint8_size) # GS 3V3 (unused)
|
||||
out_en_12 = TableEntry(bytearray([0x00, 0x74]), TableEntry.uint8_size) # GS 5V (unused)
|
||||
# When channel consumes more than cur_lu_lim, channel is turned of immediately
|
||||
cur_lu_lim_0 = TableEntry(bytearray([0x00, 0xF8]), TableEntry.uint16_size)
|
||||
|
||||
@ -48,7 +57,25 @@ class P60DockHkTable:
|
||||
wdt_gnd_left = TableEntry(bytearray([0x00, 0xA8]), TableEntry.uint32_size)
|
||||
|
||||
|
||||
def pack_p60dock_test_into(object_id: bytearray, tc_queue: TcQueueT) -> TcQueueT:
|
||||
def pack_p60dock_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code: str) -> TcQueueT:
|
||||
|
||||
if op_code == "1":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Turning stack 3V3 on"))
|
||||
parameter = 0 # set channel off
|
||||
command = pack_set_param_command(object_id, P60DockConfigTable.out_en_9.parameter_address,
|
||||
P60DockConfigTable.out_en_9.parameter_size, Channel.off)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=20, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
return tc_queue
|
||||
if op_code == "2":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Turning stack 3V3 off"))
|
||||
parameter = 0 # set channel off
|
||||
command = pack_set_param_command(object_id, P60DockConfigTable.out_en_9.parameter_address,
|
||||
P60DockConfigTable.out_en_9.parameter_size, Channel.off)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=20, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
return tc_queue
|
||||
|
||||
if P60DockTestProcedure.all or P60DockTestProcedure.reboot:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Reboot"))
|
||||
command = pack_reboot_command(object_id)
|
||||
|
@ -36,70 +36,79 @@ class PDU2TestProcedure:
|
||||
request_hk_table = False
|
||||
|
||||
|
||||
def pack_pdu2_test_into(pdu2_object_id: bytearray, p60dock_object_id: bytearray, tc_queue: TcQueueT) -> TcQueueT:
|
||||
def pack_pdu2_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code: str) -> TcQueueT:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "Testing PDU2"))
|
||||
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Enabling PDU2"))
|
||||
command = pack_set_param_command(p60dock_object_id, P60DockConfigTable.out_en_3.parameter_address,
|
||||
P60DockConfigTable.out_en_3.parameter_size, Channel.on)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command)
|
||||
if op_code == "1":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Turn ACS Side B on"))
|
||||
command = pack_set_param_command(object_id, PDUConfigTable.out_en_7.parameter_address,
|
||||
PDUConfigTable.out_en_7.parameter_size, Channel.on)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=30, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
return tc_queue
|
||||
if op_code == "2":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Turn ACS Side B off"))
|
||||
command = pack_set_param_command(object_id, PDUConfigTable.out_en_7.parameter_address,
|
||||
PDUConfigTable.out_en_7.parameter_size, Channel.off)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=31, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
return tc_queue
|
||||
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.reboot:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Reboot"))
|
||||
command = pack_reboot_command(pdu2_object_id)
|
||||
command = pack_reboot_command(object_id)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=22, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.read_gnd_wdt:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Reading ground watchdog timer value"))
|
||||
command = pack_get_param_command(pdu2_object_id, TableIds.hk, PDUHkTable.wdt_gnd_left.parameter_address,
|
||||
command = pack_get_param_command(object_id, TableIds.hk, PDUHkTable.wdt_gnd_left.parameter_address,
|
||||
PDUHkTable.wdt_gnd_left.parameter_size)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=20, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.gnd_wdt_reset:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Testing ground watchdog reset"))
|
||||
command = pack_gnd_wdt_reset_command(pdu2_object_id)
|
||||
command = pack_gnd_wdt_reset_command(object_id)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=21, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.ping:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Ping Test"))
|
||||
ping_data = bytearray([0, 1, 2, 3, 4, 5, 6, 7, 8, 9])
|
||||
command = pack_ping_command(pdu2_object_id, ping_data)
|
||||
command = pack_ping_command(object_id, ping_data)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=22, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.channel_2_on:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Testing setting output channel 2 on (TCS Heater)"))
|
||||
command = pack_set_param_command(pdu2_object_id, PDUConfigTable.out_en_2.parameter_address,
|
||||
command = pack_set_param_command(object_id, PDUConfigTable.out_en_2.parameter_address,
|
||||
PDUConfigTable.out_en_2.parameter_size, Channel.on)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.read_temperature:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Testing temperature reading"))
|
||||
command = pack_get_param_command(pdu2_object_id, TableIds.hk, PDUHkTable.temperature.parameter_address,
|
||||
command = pack_get_param_command(object_id, TableIds.hk, PDUHkTable.temperature.parameter_address,
|
||||
PDUHkTable.temperature.parameter_size)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=24, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.read_channel_2_state:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Reading output channel 2 state (TCS Heater)"))
|
||||
command = pack_get_param_command(pdu2_object_id, TableIds.config, PDUConfigTable.out_en_2.parameter_address,
|
||||
command = pack_get_param_command(object_id, TableIds.config, PDUConfigTable.out_en_2.parameter_address,
|
||||
PDUConfigTable.out_en_2.parameter_size)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=25, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.read_cur_lu_lim_0:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Reading current limit value of output channel 0 (OBC)"))
|
||||
command = pack_get_param_command(pdu2_object_id, TableIds.config, PDUConfigTable.cur_lu_lim_0.parameter_address,
|
||||
command = pack_get_param_command(object_id, TableIds.config, PDUConfigTable.cur_lu_lim_0.parameter_address,
|
||||
PDUConfigTable.cur_lu_lim_0.parameter_size)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=26, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.channel_2_off:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Testing setting output channel 2 off"))
|
||||
command = pack_set_param_command(pdu2_object_id, PDUConfigTable.out_en_2.parameter_address,
|
||||
command = pack_set_param_command(object_id, PDUConfigTable.out_en_2.parameter_address,
|
||||
PDUConfigTable.out_en_2.parameter_size, Channel.off)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=27, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if PDU2TestProcedure.all or PDU2TestProcedure.request_hk_table:
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Requesting housekeeping table"))
|
||||
command = pack_request_full_hk_table_command(pdu2_object_id)
|
||||
command = pack_request_full_hk_table_command(object_id)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=28, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
|
@ -47,16 +47,13 @@ def pack_service_queue_user(service: Union[str, int], op_code: str, service_queu
|
||||
return pack_service200_test_into(tc_queue=service_queue)
|
||||
if service == CustomServiceList.P60DOCK.value:
|
||||
object_id = P60_DOCK_HANDLER
|
||||
return pack_p60dock_test_into(object_id=object_id, tc_queue=service_queue)
|
||||
return pack_p60dock_test_into(object_id=object_id, tc_queue=service_queue, op_code=op_code)
|
||||
if service == CustomServiceList.PDU1.value:
|
||||
object_id = PDU_1_HANDLER_ID
|
||||
return pack_pdu1_test_into(object_id=object_id, tc_queue=service_queue, op_code=op_code)
|
||||
if service == CustomServiceList.PDU2.value:
|
||||
pdu2_object_id = PDU_2_HANDLER_ID
|
||||
p60dock_object_id = P60_DOCK_HANDLER
|
||||
return pack_pdu2_test_into(
|
||||
pdu2_object_id=pdu2_object_id, p60dock_object_id=p60dock_object_id, tc_queue=service_queue
|
||||
)
|
||||
object_id = PDU_2_HANDLER_ID
|
||||
return pack_pdu2_test_into(object_id=object_id, tc_queue=service_queue, op_code=op_code)
|
||||
if service == CustomServiceList.ACU.value:
|
||||
object_id = ACU_HANDLER_ID
|
||||
return pack_acu_test_into(object_id=object_id, tc_queue=service_queue)
|
||||
|
Loading…
Reference in New Issue
Block a user