Merge remote-tracking branch 'origin/main' into cfdp-file-downlink
All checks were successful
EIVE/-/pipeline/pr-main This commit looks good

This commit is contained in:
Robin Müller 2023-09-12 14:17:39 +02:00
commit 8b45dd8bff
Signed by: muellerr
GPG Key ID: A649FB78196E3849
27 changed files with 140 additions and 144 deletions

View File

@ -10,9 +10,17 @@ list yields a list of all related PRs for each release.
# [unreleased] # [unreleased]
# [v5.5.0] 2023-09-04 # [v5.5.1] 2023-09-12
- Bumped `tmtccmd` to v6.0.0rc0 ## Fixed
- Some API usage fixes related to `tmtccmd` update.
# [v5.5.0] 2023-09-12
- Version is not specfied dynamically anymore and can be updated in `pyproject.toml`
- New events and returnvalues
- Bump `tmtccmd` to v6.0.0rc0
# [v5.4.3] 2023-08-15 # [v5.4.3] 2023-08-15

View File

@ -1,13 +1,6 @@
__version__ = "5.4.3"
import logging import logging
from pathlib import Path from pathlib import Path
SW_NAME = "eive-tmtc"
VERSION_MAJOR = 5
VERSION_MINOR = 4
VERSION_REVISION = 3
EIVE_TMTC_ROOT = Path(__file__).parent EIVE_TMTC_ROOT = Path(__file__).parent
PACKAGE_ROOT = EIVE_TMTC_ROOT.parent PACKAGE_ROOT = EIVE_TMTC_ROOT.parent

View File

@ -1,7 +1,6 @@
import logging import logging
from spacepackets.cfdp import ConditionCode from spacepackets.cfdp import ConditionCode
from spacepackets.cfdp.pdu import DeliveryCode
from tmtccmd.cfdp import CfdpUserBase, TransactionId from tmtccmd.cfdp import CfdpUserBase, TransactionId
from tmtccmd.cfdp.user import ( from tmtccmd.cfdp.user import (
TransactionFinishedParams, TransactionFinishedParams,
@ -30,7 +29,8 @@ class EiveCfdpUser(CfdpUserBase):
def file_segment_recv_indication(self, params: FileSegmentRecvdParams): def file_segment_recv_indication(self, params: FileSegmentRecvdParams):
_LOGGER.info( _LOGGER.info(
f"CFDP User: Received File Data PDU for {params.transaction_id} | Offset: {params.offset} | Segment Length: {params.length}" f"CFDP User: Received File Data PDU for {params.transaction_id} | Offset:"
f" {params.offset} | Segment Length: {params.length}"
) )
def report_indication(self, transaction_id: TransactionId, status_report: any): def report_indication(self, transaction_id: TransactionId, status_report: any):

View File

@ -140,7 +140,7 @@ class TcHandler(TcHandlerBase):
if pdu.pdu_directive_type == DirectiveType.METADATA_PDU: if pdu.pdu_directive_type == DirectiveType.METADATA_PDU:
metadata = pdu.to_metadata_pdu() metadata = pdu.to_metadata_pdu()
self.queue_helper.add_log_cmd( self.queue_helper.add_log_cmd(
f"CFDP Source: Sending Metadata PDU for file with size " "CFDP Source: Sending Metadata PDU for file with size "
f"{metadata.file_size}" f"{metadata.file_size}"
) )
elif pdu.pdu_directive_type == DirectiveType.EOF_PDU: elif pdu.pdu_directive_type == DirectiveType.EOF_PDU:
@ -150,7 +150,7 @@ class TcHandler(TcHandlerBase):
else: else:
fd_pdu = pdu.to_file_data_pdu() fd_pdu = pdu.to_file_data_pdu()
self.queue_helper.add_log_cmd( self.queue_helper.add_log_cmd(
f"CFDP Source: Sending File Data PDU for segment at offset " "CFDP Source: Sending File Data PDU for segment at offset "
f"{fd_pdu.offset} with length {len(fd_pdu.file_data)}" f"{fd_pdu.offset} with length {len(fd_pdu.file_data)}"
) )
self.queue_helper.add_ccsds_tc(sp) self.queue_helper.add_ccsds_tc(sp)
@ -162,7 +162,8 @@ class TcHandler(TcHandlerBase):
if info.proc_type == TcQueueEntryType.PUS_TC: if info.proc_type == TcQueueEntryType.PUS_TC:
def_proc = info.to_def_procedure() def_proc = info.to_def_procedure()
_LOGGER.info( _LOGGER.info(
f"Finished queue for service {def_proc.service} and op code {def_proc.op_code}" f"Finished queue for service {def_proc.service} and op code"
f" {def_proc.op_code}"
) )
elif info.proc_type == TcProcedureType.CFDP: elif info.proc_type == TcProcedureType.CFDP:
_LOGGER.info("Finished CFDP queue") _LOGGER.info("Finished CFDP queue")

View File

@ -42,7 +42,8 @@ def handle_event_packet( # noqa C901: Complexity okay here
) )
_LOGGER.info(generic_event_string) _LOGGER.info(generic_event_string)
pw.file_logger.info( pw.file_logger.info(
f"{datetime.datetime.now().strftime('%Y-%m-%d %H:%M:%S')}: {generic_event_string}" f"{datetime.datetime.now().strftime('%Y-%m-%d %H:%M:%S')}:"
f" {generic_event_string}"
) )
specific_handler = False specific_handler = False
if info.name == "MODE_TRANSITION_FAILED": if info.name == "MODE_TRANSITION_FAILED":
@ -54,8 +55,8 @@ def handle_event_packet( # noqa C901: Complexity okay here
if info.name == "SUPV_UPDATE_PROGRESS" or info.name == "WRITE_MEMORY_FAILED": if info.name == "SUPV_UPDATE_PROGRESS" or info.name == "WRITE_MEMORY_FAILED":
additional_event_info = f"Additional info: {info.info}" additional_event_info = f"Additional info: {info.info}"
context = ( context = (
f"Progress Percent: {event_def.param1 >> 24 & 0xff} | " f"Progress Percent: {event_def.param1 >> 24 & 0xff} | Sequence Count:"
f"Sequence Count: {event_def.param1 & 0xffff} | Bytes Written: {event_def.param2}" f" {event_def.param1 & 0xffff} | Bytes Written: {event_def.param2}"
) )
pw.dlog(additional_event_info) pw.dlog(additional_event_info)
pw.dlog(context) pw.dlog(context)

View File

@ -188,5 +188,5 @@ def handle_regular_hk_print( # noqa C901: Complexity okay here
else: else:
_LOGGER.info( _LOGGER.info(
f"Service 3 TM: Parsing for object {object_id} and set ID {set_id} " f"Service 3 TM: Parsing for object {object_id} and set ID {set_id} "
f"has not been implemented." "has not been implemented."
) )

View File

@ -87,7 +87,8 @@ def pus_factory_hook( # noqa C901 : Complexity okay here
# TODO: Could improve display further by actually displaying a matrix as a # TODO: Could improve display further by actually displaying a matrix as a
# matrix using row and column information # matrix using row and column information
pw.dlog( pw.dlog(
f"Received vector or matrix data: {param.param_raw.hex(sep=',')}" "Received vector or matrix data:"
f" {param.param_raw.hex(sep=',')}"
) )
except ValueError as e: except ValueError as e:
pw.dlog(f"received {e} when trying to parse parameters") pw.dlog(f"received {e} when trying to parse parameters")

View File

@ -48,7 +48,7 @@ def generic_retval_printout(
if retval_info is None: if retval_info is None:
raw_err = retval raw_err = retval
return [ return [
f"No returnvalue information found for error code with " "No returnvalue information found for error code with "
f"subsystem ID {(raw_err >> 8) & 0xff} and unique ID {raw_err & 0xff}" f"subsystem ID {(raw_err >> 8) & 0xff} and unique ID {raw_err & 0xff}"
] ]
else: else:
@ -58,9 +58,9 @@ def generic_retval_printout(
) )
string_list = [retval_string] string_list = [retval_string]
if p1: if p1:
error_param_1_str = f"Error Parameter 1: hex {p1:#010x} " f"dec {p1} " error_param_1_str = f"Error Parameter 1: hex {p1:#010x} dec {p1} "
string_list.append(error_param_1_str) string_list.append(error_param_1_str)
if p2: if p2:
error_param_2_str = f"Error Parameter 2: hex {p2:#010x} " f"dec {p2}" error_param_2_str = f"Error Parameter 2: hex {p2:#010x} dec {p2}"
string_list.append(error_param_2_str) string_list.append(error_param_2_str)
return string_list return string_list

View File

@ -571,8 +571,8 @@ def pack_acs_ctrl_command(p: ServiceProviderParams): # noqa C901
def set_acs_ctrl_param_scalar(q: DefaultPusQueueHelper): def set_acs_ctrl_param_scalar(q: DefaultPusQueueHelper):
pt = int( pt = int(
input( input(
'Specify parameter type to set {0: "uint8", 1: "uint16", 2: "int32", 3: "float", ' 'Specify parameter type to set {0: "uint8", 1: "uint16", 2: "int32", 3:'
'4: "double"}: ' ' "float", 4: "double"}: '
) )
) )
sid = int(input("Specify parameter struct ID to set: ")) sid = int(input("Specify parameter struct ID to set: "))
@ -808,8 +808,8 @@ def handle_acs_ctrl_sus_raw_data(pw: PrintWrapper, hk_data: bytes):
def handle_acs_ctrl_sus_processed_data(pw: PrintWrapper, hk_data: bytes): def handle_acs_ctrl_sus_processed_data(pw: PrintWrapper, hk_data: bytes):
if len(hk_data) < 3 * 4 * 12 + 3 * 8 * 3: if len(hk_data) < 3 * 4 * 12 + 3 * 8 * 3:
pw.dlog( pw.dlog(
f"SUS Processed dataset with size {len(hk_data)} does not have expected size" f"SUS Processed dataset with size {len(hk_data)} does not have expected"
f" of {3 * 4 * 12 + 3 * 8 * 3} bytes" f" size of {3 * 4 * 12 + 3 * 8 * 3} bytes"
) )
return return
current_idx = 0 current_idx = 0
@ -846,7 +846,8 @@ def handle_raw_mgm_data(pw: PrintWrapper, hk_data: bytes):
if len(hk_data) < 61: if len(hk_data) < 61:
pw.dlog( pw.dlog(
f"ACS CTRL HK: MGM HK data with length {len(hk_data)} shorter than expected 61 bytes" f"ACS CTRL HK: MGM HK data with length {len(hk_data)} shorter than expected"
" 61 bytes"
) )
pw.dlog(f"Raw Data: {hk_data.hex(sep=',')}") pw.dlog(f"Raw Data: {hk_data.hex(sep=',')}")
return return
@ -1276,8 +1277,8 @@ def perform_mgm_calibration( # noqa C901: Complexity okay
reply = CALIBR_SOCKET.recv(1024) reply = CALIBR_SOCKET.recv(1024)
if len(reply) != 2: if len(reply) != 2:
pw.dlog( pw.dlog(
f"MGM calibration: Reply received command magnetometer_field has invalid " "MGM calibration: Reply received command magnetometer_field has"
f"length {len(reply)}" f" invalid length {len(reply)}"
) )
return return
else: else:

View File

@ -12,8 +12,8 @@ from tmtccmd.tc import DefaultPusQueueHelper
from tmtccmd.tc.pus_3_fsfw_hk import ( from tmtccmd.tc.pus_3_fsfw_hk import (
make_sid, make_sid,
create_request_one_hk_command, create_request_one_hk_command,
create_enable_periodic_hk_command_with_interval, create_enable_periodic_hk_command_with_interval_with_diag,
create_disable_periodic_hk_command, create_disable_periodic_hk_command_with_diag,
) )
from tmtccmd.fsfw.tmtc_printer import FsfwTmTcPrinter from tmtccmd.fsfw.tmtc_printer import FsfwTmTcPrinter
@ -72,7 +72,9 @@ def add_gps_cmds(defs: TmtcDefinitionWrapper):
) )
def pack_gps_command(object_id: bytes, q: DefaultPusQueueHelper, op_code: str): def pack_gps_command( # noqa: C901
object_id: bytes, q: DefaultPusQueueHelper, op_code: str
): # noqa: C901:
if op_code in OpCode.RESET_GNSS: if op_code in OpCode.RESET_GNSS:
# TODO: This needs to be re-implemented # TODO: This needs to be re-implemented
_LOGGER.warning("Reset pin handling needs to be re-implemented") _LOGGER.warning("Reset pin handling needs to be re-implemented")
@ -81,7 +83,7 @@ def pack_gps_command(object_id: bytes, q: DefaultPusQueueHelper, op_code: str):
if interval <= 0: if interval <= 0:
raise ValueError("invalid interval") raise ValueError("invalid interval")
q.add_log_cmd(f"GPS: {Info.ENABLE_CORE_HK}") q.add_log_cmd(f"GPS: {Info.ENABLE_CORE_HK}")
cmds = create_enable_periodic_hk_command_with_interval( cmds = create_enable_periodic_hk_command_with_interval_with_diag(
diag=False, diag=False,
sid=make_sid(object_id=object_id, set_id=SetId.CORE_HK), sid=make_sid(object_id=object_id, set_id=SetId.CORE_HK),
interval_seconds=interval, interval_seconds=interval,
@ -91,7 +93,7 @@ def pack_gps_command(object_id: bytes, q: DefaultPusQueueHelper, op_code: str):
if op_code in OpCode.DISABLE_CORE_HK: if op_code in OpCode.DISABLE_CORE_HK:
q.add_log_cmd(f"gps: {Info.DISABLE_CORE_HK}") q.add_log_cmd(f"gps: {Info.DISABLE_CORE_HK}")
q.add_pus_tc( q.add_pus_tc(
create_disable_periodic_hk_command( create_disable_periodic_hk_command_with_diag(
diag=False, sid=make_sid(object_id=object_id, set_id=SetId.CORE_HK) diag=False, sid=make_sid(object_id=object_id, set_id=SetId.CORE_HK)
) )
) )
@ -107,7 +109,7 @@ def pack_gps_command(object_id: bytes, q: DefaultPusQueueHelper, op_code: str):
if interval <= 0: if interval <= 0:
raise ValueError("invalid interval") raise ValueError("invalid interval")
q.add_log_cmd(f"GPS: {Info.ENABLE_SKYVIEW_HK}") q.add_log_cmd(f"GPS: {Info.ENABLE_SKYVIEW_HK}")
cmds = create_enable_periodic_hk_command_with_interval( cmds = create_enable_periodic_hk_command_with_interval_with_diag(
diag=False, diag=False,
sid=make_sid(object_id=object_id, set_id=SetId.SKYVIEW_HK), sid=make_sid(object_id=object_id, set_id=SetId.SKYVIEW_HK),
interval_seconds=interval, interval_seconds=interval,
@ -117,7 +119,7 @@ def pack_gps_command(object_id: bytes, q: DefaultPusQueueHelper, op_code: str):
if op_code in OpCode.DISABLE_SKYVIEW_HK: if op_code in OpCode.DISABLE_SKYVIEW_HK:
q.add_log_cmd(f"gps: {Info.DISABLE_SKYVIEW_HK}") q.add_log_cmd(f"gps: {Info.DISABLE_SKYVIEW_HK}")
q.add_pus_tc( q.add_pus_tc(
create_disable_periodic_hk_command( create_disable_periodic_hk_command_with_diag(
diag=False, sid=make_sid(object_id=object_id, set_id=SetId.SKYVIEW_HK) diag=False, sid=make_sid(object_id=object_id, set_id=SetId.SKYVIEW_HK)
) )
) )

View File

@ -24,8 +24,8 @@ from tmtccmd.tc.pus_3_fsfw_hk import (
generate_one_diag_command, generate_one_diag_command,
generate_one_hk_command, generate_one_hk_command,
create_request_one_diag_command, create_request_one_diag_command,
create_disable_periodic_hk_command, create_enable_periodic_hk_command_with_interval_with_diag,
create_enable_periodic_hk_command_with_interval, create_disable_periodic_hk_command_with_diag,
) )
from tmtccmd.tc.pus_200_fsfw_mode import pack_mode_data, Mode from tmtccmd.tc.pus_200_fsfw_mode import pack_mode_data, Mode
from tmtccmd.util import ObjectIdU32 from tmtccmd.util import ObjectIdU32
@ -227,12 +227,13 @@ def pack_imtq_test_into( # noqa C901
duration = int( duration = int(
input( input(
f"Specify torque duration [range [0, {pow(2, 16) - 1}, " f"Specify torque duration [range [0, {pow(2, 16) - 1}, "
f"0 for continuous generation until update]: " "0 for continuous generation until update]: "
) )
) )
dur_str = "infinite" if duration == 0 else str(duration) dur_str = "infinite" if duration == 0 else str(duration)
q.add_log_cmd( q.add_log_cmd(
f"IMTQ: Commanding dipole X={x_dipole}, Y={y_dipole}, Z={y_dipole}, duration={dur_str}" f"IMTQ: Commanding dipole X={x_dipole}, Y={y_dipole}, Z={y_dipole},"
f" duration={dur_str}"
) )
q.add_pus_tc( q.add_pus_tc(
pack_dipole_command( pack_dipole_command(
@ -248,7 +249,7 @@ def pack_imtq_test_into( # noqa C901
if op_code == OpCode.ENABLE_ENG_HK_NO_TORQUE: if op_code == OpCode.ENABLE_ENG_HK_NO_TORQUE:
q.add_log_cmd("IMTQ: Enable ENG HK") q.add_log_cmd("IMTQ: Enable ENG HK")
interval = float(input("Please enter collection interval in seconds: ")) interval = float(input("Please enter collection interval in seconds: "))
cmds = create_enable_periodic_hk_command_with_interval( cmds = create_enable_periodic_hk_command_with_interval_with_diag(
diag=True, diag=True,
sid=make_sid(object_id.as_bytes, ImtqSetId.ENG_HK_NO_TORQUE), sid=make_sid(object_id.as_bytes, ImtqSetId.ENG_HK_NO_TORQUE),
interval_seconds=interval, interval_seconds=interval,
@ -258,7 +259,7 @@ def pack_imtq_test_into( # noqa C901
if op_code == OpCode.DISABLE_ENG_HK_NO_TORQUE: if op_code == OpCode.DISABLE_ENG_HK_NO_TORQUE:
q.add_log_cmd("IMTQ: Disable ENG HK (No Torque)") q.add_log_cmd("IMTQ: Disable ENG HK (No Torque)")
q.add_pus_tc( q.add_pus_tc(
create_disable_periodic_hk_command( create_disable_periodic_hk_command_with_diag(
True, make_sid(object_id.as_bytes, ImtqSetId.ENG_HK_NO_TORQUE) True, make_sid(object_id.as_bytes, ImtqSetId.ENG_HK_NO_TORQUE)
) )
) )
@ -275,7 +276,7 @@ def pack_imtq_test_into( # noqa C901
if op_code == OpCode.ENABLE_ENG_HK_WITH_TORQUE: if op_code == OpCode.ENABLE_ENG_HK_WITH_TORQUE:
q.add_log_cmd("IMTQ: Enable ENG HK with torque") q.add_log_cmd("IMTQ: Enable ENG HK with torque")
interval = float(input("Please enter collection interval in seconds: ")) interval = float(input("Please enter collection interval in seconds: "))
cmds = create_enable_periodic_hk_command_with_interval( cmds = create_enable_periodic_hk_command_with_interval_with_diag(
diag=True, diag=True,
sid=make_sid(object_id.as_bytes, ImtqSetId.ENG_HK_SET_WITH_TORQUE), sid=make_sid(object_id.as_bytes, ImtqSetId.ENG_HK_SET_WITH_TORQUE),
interval_seconds=interval, interval_seconds=interval,
@ -285,7 +286,7 @@ def pack_imtq_test_into( # noqa C901
if op_code == OpCode.DISABLE_ENG_HK_WITH_TORQUE: if op_code == OpCode.DISABLE_ENG_HK_WITH_TORQUE:
q.add_log_cmd("IMTQ: Disable ENG HK with Torque") q.add_log_cmd("IMTQ: Disable ENG HK with Torque")
q.add_pus_tc( q.add_pus_tc(
create_disable_periodic_hk_command( create_disable_periodic_hk_command_with_diag(
True, make_sid(object_id.as_bytes, ImtqSetId.ENG_HK_SET_WITH_TORQUE) True, make_sid(object_id.as_bytes, ImtqSetId.ENG_HK_SET_WITH_TORQUE)
) )
) )
@ -320,14 +321,14 @@ def pack_imtq_test_into( # noqa C901
if op_code == OpCode.DISABLE_MGM_RAW_NO_TORQUE: if op_code == OpCode.DISABLE_MGM_RAW_NO_TORQUE:
q.add_log_cmd("IMTQ: Disable MGM RAW HK (No Torque)") q.add_log_cmd("IMTQ: Disable MGM RAW HK (No Torque)")
q.add_pus_tc( q.add_pus_tc(
create_disable_periodic_hk_command( create_disable_periodic_hk_command_with_diag(
True, make_sid(object_id.as_bytes, ImtqSetId.RAW_MTM_NO_TORQUE) True, make_sid(object_id.as_bytes, ImtqSetId.RAW_MTM_NO_TORQUE)
) )
) )
if op_code == OpCode.ENABLE_MGM_RAW_NO_TORQUE: if op_code == OpCode.ENABLE_MGM_RAW_NO_TORQUE:
q.add_log_cmd("IMTQ: Enable MGM RAW HK (No Torque)") q.add_log_cmd("IMTQ: Enable MGM RAW HK (No Torque)")
interval = float(input("Please enter collection interval in seconds: ")) interval = float(input("Please enter collection interval in seconds: "))
cmds = create_enable_periodic_hk_command_with_interval( cmds = create_enable_periodic_hk_command_with_interval_with_diag(
diag=True, diag=True,
sid=make_sid(object_id.as_bytes, ImtqSetId.RAW_MTM_NO_TORQUE), sid=make_sid(object_id.as_bytes, ImtqSetId.RAW_MTM_NO_TORQUE),
interval_seconds=interval, interval_seconds=interval,
@ -346,7 +347,7 @@ def pack_imtq_test_into( # noqa C901
if op_code == OpCode.ENABLE_MGM_RAW_WITH_TORQUE: if op_code == OpCode.ENABLE_MGM_RAW_WITH_TORQUE:
q.add_log_cmd("IMTQ: Enable MGM RAW HK (No Torque)") q.add_log_cmd("IMTQ: Enable MGM RAW HK (No Torque)")
interval = float(input("Please enter collection interval in seconds: ")) interval = float(input("Please enter collection interval in seconds: "))
cmds = create_enable_periodic_hk_command_with_interval( cmds = create_enable_periodic_hk_command_with_interval_with_diag(
diag=True, diag=True,
sid=make_sid(object_id.as_bytes, ImtqSetId.RAW_MTM_WITH_TORQUE), sid=make_sid(object_id.as_bytes, ImtqSetId.RAW_MTM_WITH_TORQUE),
interval_seconds=interval, interval_seconds=interval,
@ -356,7 +357,7 @@ def pack_imtq_test_into( # noqa C901
if op_code == OpCode.DISABLE_MGM_RAW_WITH_TORQUE: if op_code == OpCode.DISABLE_MGM_RAW_WITH_TORQUE:
q.add_log_cmd("IMTQ: Disable MGM RAW HK (No Torque)") q.add_log_cmd("IMTQ: Disable MGM RAW HK (No Torque)")
q.add_pus_tc( q.add_pus_tc(
create_disable_periodic_hk_command( create_disable_periodic_hk_command_with_diag(
True, make_sid(object_id.as_bytes, ImtqSetId.RAW_MTM_WITH_TORQUE) True, make_sid(object_id.as_bytes, ImtqSetId.RAW_MTM_WITH_TORQUE)
) )
) )
@ -388,7 +389,8 @@ def pack_dipole_command(
duration = int(round(duration)) duration = int(round(duration))
if duration < 0 or duration > pow(2, 16) - 1: if duration < 0 or duration > pow(2, 16) - 1:
raise ValueError( raise ValueError(
f"Duration in ms of {duration} smaller than 0 or larger than allowed {pow(2, 16) - 1}" f"Duration in ms of {duration} smaller than 0 or larger than allowed"
f" {pow(2, 16) - 1}"
) )
command += struct.pack("!h", x_dipole) command += struct.pack("!h", x_dipole)
command += struct.pack("!h", y_dipole) command += struct.pack("!h", y_dipole)
@ -400,7 +402,8 @@ def pack_dipole_command(
def raise_dipole_error(dipole_str: str, value: int): def raise_dipole_error(dipole_str: str, value: int):
raise ValueError( raise ValueError(
f"{dipole_str} {value} negative or larger than maximum allowed 2000 * 10^-4*Am^2" f"{dipole_str} {value} negative or larger than maximum allowed 2000 *"
" 10^-4*Am^2"
) )

View File

@ -261,14 +261,12 @@ def pack_set_speed_command(
if speed > 0: if speed > 0:
if speed < 1000 or speed > 65000: if speed < 1000 or speed > 65000:
raise ValueError( raise ValueError(
"Invalid RW speed specified. " "Invalid RW speed specified. Allowed range is [1000, 65000] 0.1 * RPM"
"Allowed range is [1000, 65000] 0.1 * RPM"
) )
elif speed < 0: elif speed < 0:
if speed < -65000 or speed > -1000: if speed < -65000 or speed > -1000:
raise ValueError( raise ValueError(
"Invalid RW speed specified. " "Invalid RW speed specified. Allowed range is [-65000, -1000] 0.1 * RPM"
"Allowed range is [-65000, -1000] 0.1 * RPM"
) )
else: else:
# Speed is 0 # Speed is 0
@ -304,15 +302,16 @@ def handle_rw_hk_data(
speed_rpm = speed / 10.0 speed_rpm = speed / 10.0
ref_speed_rpm = ref_speed / 10.0 ref_speed_rpm = ref_speed / 10.0
pw.dlog( pw.dlog(
f"Temperature {temp} C | Speed {speed_rpm} rpm | Reference Speed {ref_speed_rpm} rpm" f"Temperature {temp} C | Speed {speed_rpm} rpm | Reference Speed"
f" {ref_speed_rpm} rpm"
) )
pw.dlog( pw.dlog(
f"State {state}. 0: Error, 1: Idle, 2: Coasting, 3: Running, speed stable, " f"State {state}. 0: Error, 1: Idle, 2: Coasting, 3: Running, speed stable, "
f"4: Running, speed changing" "4: Running, speed changing"
) )
pw.dlog( pw.dlog(
f"Current Limit Control mode {clc_mode}. 0: Low Current Mode (0.3 A), " f"Current Limit Control mode {clc_mode}. 0: Low Current Mode (0.3 A), "
f"1: High Current Mode (0.6 A)" "1: High Current Mode (0.6 A)"
) )
pw.dlog(FsfwTmTcPrinter.get_validity_buffer(hk_data[current_idx:], 5)) pw.dlog(FsfwTmTcPrinter.get_validity_buffer(hk_data[current_idx:], 5))
if set_id == RwSetId.LAST_RESET: if set_id == RwSetId.LAST_RESET:
@ -361,22 +360,24 @@ def handle_rw_hk_data(
) = struct.unpack(fmt_str, hk_data[current_idx : current_idx + inc_len]) ) = struct.unpack(fmt_str, hk_data[current_idx : current_idx + inc_len])
pw.dlog( pw.dlog(
f"MCU Temperature {mcu_temp} | Pressure Sensore Temperature {pressure_sens_temp} C" f"MCU Temperature {mcu_temp} | Pressure Sensore Temperature"
f" {pressure_sens_temp} C"
) )
pw.dlog(f"Last Reset Status {last_reset_status}") pw.dlog(f"Last Reset Status {last_reset_status}")
pw.dlog( pw.dlog(
f"Current Limit Control mode {clc_mode}. 0: Low Current Mode (0.3 A), " f"Current Limit Control mode {clc_mode}. 0: Low Current Mode (0.3 A), "
f"1: High Current Mode (0.6 A)" "1: High Current Mode (0.6 A)"
) )
pw.dlog(f"Speed {current_speed} rpm | Reference Speed {ref_speed} rpm") pw.dlog(f"Speed {current_speed} rpm | Reference Speed {ref_speed} rpm")
pw.dlog( pw.dlog(
f"State {state}. 0: Error, 1: Idle, 2: Coasting, 3: Running, speed stable, " f"State {state}. 0: Error, 1: Idle, 2: Coasting, 3: Running, speed stable, "
f"4: Running, speed changing" "4: Running, speed changing"
) )
pw.dlog("Number Of Invalid Packets:") pw.dlog("Number Of Invalid Packets:")
pw.dlog("CRC | Length | CMD") pw.dlog("CRC | Length | CMD")
pw.dlog( pw.dlog(
f"{num_invalid_crc_packets} | {num_invalid_len_packets} | {num_invalid_cmd_packets}" f"{num_invalid_crc_packets} | {num_invalid_len_packets} |"
f" {num_invalid_cmd_packets}"
) )
pw.dlog( pw.dlog(
f"Num Of CMD Executed Requests {num_of_cmd_executed_requests} | " f"Num Of CMD Executed Requests {num_of_cmd_executed_requests} | "
@ -388,15 +389,16 @@ def handle_rw_hk_data(
"RegOverrunErrs | TotalErrs" "RegOverrunErrs | TotalErrs"
) )
pw.dlog( pw.dlog(
f"{uart_num_of_bytes_written} | {uart_num_of_bytes_read} | {uart_num_parity_errors} | " f"{uart_num_of_bytes_written} | {uart_num_of_bytes_read} |"
f"{uart_num_noise_errors} | {uart_num_frame_errors} | {uart_num_reg_overrun_errors} | " f" {uart_num_parity_errors} | {uart_num_noise_errors} |"
f" {uart_num_frame_errors} | {uart_num_reg_overrun_errors} |"
f" {uart_total_num_errors}" f" {uart_total_num_errors}"
) )
pw.dlog("SPI COM Info:") pw.dlog("SPI COM Info:")
pw.dlog("NumBytesWritten | NumBytesRead | RegOverrunErrs | TotalErrs") pw.dlog("NumBytesWritten | NumBytesRead | RegOverrunErrs | TotalErrs")
pw.dlog( pw.dlog(
f"{spi_num_bytes_written} | {spi_num_bytes_read} | {spi_num_reg_overrun_errors} | " f"{spi_num_bytes_written} | {spi_num_bytes_read} |"
f"{spi_total_num_errors}" f" {spi_num_reg_overrun_errors} | {spi_total_num_errors}"
) )
if current_idx > 0: if current_idx > 0:
pw.dlog( pw.dlog(

View File

@ -83,7 +83,7 @@ def pack_pdec_handler_test(
0, 0,
ParameterId.POSITIVE_WINDOW, ParameterId.POSITIVE_WINDOW,
pw, pw,
).pack() )
) )
) )
if op_code == OpCode.NEGATIVE_WINDOW: if op_code == OpCode.NEGATIVE_WINDOW:
@ -96,7 +96,7 @@ def pack_pdec_handler_test(
0, 0,
ParameterId.NEGATIVE_WINDOW, ParameterId.NEGATIVE_WINDOW,
nw, nw,
).pack() )
) )
) )
if op_code == OpCode.RESET_NO_INIT: if op_code == OpCode.RESET_NO_INIT:

View File

@ -3,6 +3,7 @@ import enum
from eive_tmtc.config.definitions import CustomServiceList from eive_tmtc.config.definitions import CustomServiceList
from eive_tmtc.config.object_ids import COM_SUBSYSTEM_ID from eive_tmtc.config.object_ids import COM_SUBSYSTEM_ID
from eive_tmtc.tmtc.com.syrlinks_handler import Datarate from eive_tmtc.tmtc.com.syrlinks_handler import Datarate
from tmtccmd.pus.s20_fsfw_param_defs import create_scalar_u8_parameter
from .defs import Mode as ComMode from .defs import Mode as ComMode
@ -21,7 +22,6 @@ from tmtccmd.tc.pus_200_fsfw_mode import (
) )
from tmtccmd.tc.pus_20_fsfw_param import ( from tmtccmd.tc.pus_20_fsfw_param import (
create_load_param_cmd, create_load_param_cmd,
pack_scalar_u8_parameter_app_data,
) )
from tmtccmd.pus.s20_fsfw_param import create_scalar_u32_parameter from tmtccmd.pus.s20_fsfw_param import create_scalar_u32_parameter
@ -87,7 +87,7 @@ def build_com_subsystem_cmd(p: ServiceProviderParams): # noqa C901
q.add_log_cmd(f"{prefix}: {Info.UPDATE_DEFAULT_DATARATE_LOW}") q.add_log_cmd(f"{prefix}: {Info.UPDATE_DEFAULT_DATARATE_LOW}")
q.add_pus_tc( q.add_pus_tc(
create_load_param_cmd( create_load_param_cmd(
pack_scalar_u8_parameter_app_data( create_scalar_u8_parameter(
COM_SUBSYSTEM_ID, COM_SUBSYSTEM_ID,
0, 0,
ParameterId.DATARATE, ParameterId.DATARATE,
@ -99,7 +99,7 @@ def build_com_subsystem_cmd(p: ServiceProviderParams): # noqa C901
q.add_log_cmd(f"{prefix}: {Info.UPDATE_DEFAULT_DATARATE_HIGH}") q.add_log_cmd(f"{prefix}: {Info.UPDATE_DEFAULT_DATARATE_HIGH}")
q.add_pus_tc( q.add_pus_tc(
create_load_param_cmd( create_load_param_cmd(
pack_scalar_u8_parameter_app_data( create_scalar_u8_parameter(
COM_SUBSYSTEM_ID, COM_SUBSYSTEM_ID,
0, 0,
ParameterId.DATARATE, ParameterId.DATARATE,
@ -122,7 +122,7 @@ def build_com_subsystem_cmd(p: ServiceProviderParams): # noqa C901
0, 0,
ParameterId.TRANSMITTER_TIMEOUT, ParameterId.TRANSMITTER_TIMEOUT,
timeout, timeout,
).pack() )
) )
) )
elif o == OpCode.READ_MODE: elif o == OpCode.READ_MODE:

View File

@ -21,9 +21,9 @@ from tmtccmd.tc import DefaultPusQueueHelper
from tmtccmd.tc.pus_3_fsfw_hk import ( from tmtccmd.tc.pus_3_fsfw_hk import (
make_sid, make_sid,
create_request_one_diag_command, create_request_one_diag_command,
create_enable_periodic_hk_command_with_interval,
create_disable_periodic_hk_command,
create_request_one_hk_command, create_request_one_hk_command,
create_enable_periodic_hk_command_with_interval_with_diag,
create_disable_periodic_hk_command_with_diag,
) )
from spacepackets.ecss.tc import PusTelecommand from spacepackets.ecss.tc import PusTelecommand
from tmtccmd.tc.pus_200_fsfw_mode import Mode, create_mode_command from tmtccmd.tc.pus_200_fsfw_mode import Mode, create_mode_command
@ -182,24 +182,28 @@ def pack_syrlinks_command( # noqa C901: Complexity okay here.
q.add_log_cmd(f"{prefix}: {Info.ENABLE_HK_RX_REGS}") q.add_log_cmd(f"{prefix}: {Info.ENABLE_HK_RX_REGS}")
sid = make_sid(obyt, SetId.RX_REGISTERS_DATASET) sid = make_sid(obyt, SetId.RX_REGISTERS_DATASET)
interval = float(input("HK interval in floating point seconds")) interval = float(input("HK interval in floating point seconds"))
cmds = create_enable_periodic_hk_command_with_interval(True, sid, interval) cmds = create_enable_periodic_hk_command_with_interval_with_diag(
True, sid, interval
)
for cmd in cmds: for cmd in cmds:
q.add_pus_tc(cmd) q.add_pus_tc(cmd)
if op_code in OpCode.DISABLE_HK_RX_REGS: if op_code in OpCode.DISABLE_HK_RX_REGS:
q.add_log_cmd(f"{prefix}: {Info.DISABLE_HK_RX_REGS}") q.add_log_cmd(f"{prefix}: {Info.DISABLE_HK_RX_REGS}")
sid = make_sid(obyt, SetId.RX_REGISTERS_DATASET) sid = make_sid(obyt, SetId.RX_REGISTERS_DATASET)
q.add_pus_tc(create_disable_periodic_hk_command(True, sid)) q.add_pus_tc(create_disable_periodic_hk_command_with_diag(True, sid))
if op_code in OpCode.ENABLE_HK_TX_REGS: if op_code in OpCode.ENABLE_HK_TX_REGS:
q.add_log_cmd(f"{prefix}: {Info.ENABLE_HK_TX_REGS}") q.add_log_cmd(f"{prefix}: {Info.ENABLE_HK_TX_REGS}")
sid = make_sid(obyt, SetId.TX_REGISTERS_DATASET) sid = make_sid(obyt, SetId.TX_REGISTERS_DATASET)
interval = float(input("HK interval in floating point seconds")) interval = float(input("HK interval in floating point seconds"))
cmds = create_enable_periodic_hk_command_with_interval(True, sid, interval) cmds = create_enable_periodic_hk_command_with_interval_with_diag(
True, sid, interval
)
for cmd in cmds: for cmd in cmds:
q.add_pus_tc(cmd) q.add_pus_tc(cmd)
if op_code in OpCode.DISABLE_HK_TX_REGS: if op_code in OpCode.DISABLE_HK_TX_REGS:
q.add_log_cmd(f"{prefix}: {Info.DISABLE_HK_TX_REGS}") q.add_log_cmd(f"{prefix}: {Info.DISABLE_HK_TX_REGS}")
sid = make_sid(obyt, SetId.TX_REGISTERS_DATASET) sid = make_sid(obyt, SetId.TX_REGISTERS_DATASET)
q.add_pus_tc(create_disable_periodic_hk_command(True, sid)) q.add_pus_tc(create_disable_periodic_hk_command_with_diag(True, sid))
if op_code in OpCode.HK_TX_REGS: if op_code in OpCode.HK_TX_REGS:
q.add_log_cmd(f"{prefix}: {Info.HK_TX_REGS}") q.add_log_cmd(f"{prefix}: {Info.HK_TX_REGS}")
sid = make_sid(obyt, SetId.TX_REGISTERS_DATASET) sid = make_sid(obyt, SetId.TX_REGISTERS_DATASET)

View File

@ -570,12 +570,12 @@ def handle_ploc_mpsoc_hk_data(pw: PrintWrapper, hk_data: bytes, set_id: int):
pw.dlog(f"CAM SoC Temperature: {cam_soc_temp}") pw.dlog(f"CAM SoC Temperature: {cam_soc_temp}")
pw.dlog(f"System Monitor Temperature: {sysmon_temp}") pw.dlog(f"System Monitor Temperature: {sysmon_temp}")
pw.dlog( pw.dlog(
f"SYSMON VCC INT {sysmon_vcc_int:.3f} | SYSMON VCC AUX {sysmon_vcc_aux:.3f} | " f"SYSMON VCC INT {sysmon_vcc_int:.3f} | SYSMON VCC AUX"
f"SYSMON VCC BRAM {sysmon_vcc_bram:.3f}" f" {sysmon_vcc_aux:.3f} | SYSMON VCC BRAM {sysmon_vcc_bram:.3f}"
) )
pw.dlog( pw.dlog(
f"SYSMON VCC PAUX {sysmon_vcc_paux:.3f} | SYSMON VCC PINT {sysmon_vcc_pint:.3f} | " f"SYSMON VCC PAUX {sysmon_vcc_paux:.3f} | SYSMON VCC PINT"
f"SYSMON VCC PDRO {sysmon_vcc_pdro:.3f}" f" {sysmon_vcc_pint:.3f} | SYSMON VCC PDRO {sysmon_vcc_pdro:.3f}"
) )
fmt_str = "!fffffffffffff" fmt_str = "!fffffffffffff"
@ -603,7 +603,8 @@ def handle_ploc_mpsoc_hk_data(pw: PrintWrapper, hk_data: bytes, set_id: int):
) )
pw.dlog( pw.dlog(
f"SYSMON VCC 12V {sysmon_vcc_12v:.3f} | SYSMON VCC 5V {sysmon_vcc_5v:.3f} |" f"SYSMON VCC 12V {sysmon_vcc_12v:.3f} | SYSMON VCC 5V {sysmon_vcc_5v:.3f} |"
f"SYSMON VCC 3V3 {sysmon_vcc_3v3:.3f} | SYSMON VCC 3V3VA {sysmon_vcc_3v3va}" f" SYSMON VCC 3V3 {sysmon_vcc_3v3:.3f} | SYSMON VCC 3V3VA"
f" {sysmon_vcc_3v3va}"
) )
pw.dlog( pw.dlog(
f"SYSMON VCC 2V5DDR {sysmon_vcc_2v5ddr:.3f} | " f"SYSMON VCC 2V5DDR {sysmon_vcc_2v5ddr:.3f} | "

View File

@ -471,8 +471,8 @@ def pack_ploc_supv_commands(p: ServiceProviderParams): # noqa C901
custom_data.extend(struct.pack("!B", memory_id)) custom_data.extend(struct.pack("!B", memory_id))
custom_data.extend(struct.pack("!I", start_address)) custom_data.extend(struct.pack("!I", start_address))
q.add_log_cmd( q.add_log_cmd(
f"{prefix}: {Info.MEM_CHECK} for file {update_file} at memory ID {memory_id} at start " f"{prefix}: {Info.MEM_CHECK} for file {update_file} at memory ID"
f"address {start_address}" f" {memory_id} at start address {start_address}"
) )
command = create_action_cmd( command = create_action_cmd(
object_id.as_bytes, SupvActionId.MEM_CHECK, custom_data object_id.as_bytes, SupvActionId.MEM_CHECK, custom_data
@ -775,7 +775,8 @@ def handle_supv_hk_data(set_id: int, hk_data: bytes, pw: PrintWrapper):
) = struct.unpack(fmt_str, hk_data[0 : 0 + inc_len]) ) = struct.unpack(fmt_str, hk_data[0 : 0 + inc_len])
current_idx += inc_len current_idx += inc_len
pw.dlog( pw.dlog(
f"SoC state (0:off, 1:booting, 2:update, 3:operating, 4:shutdown, 5:reset): {soc_state}" "SoC state (0:off, 1:booting, 2:update, 3:operating, 4:shutdown, 5:reset):"
f" {soc_state}"
) )
pw.dlog(f"Power Cycles {power_cycles}") pw.dlog(f"Power Cycles {power_cycles}")
pw.dlog(f"Boot after {boot_after_ms} ms | Boot timeout {boot_timeout_ms} ms") pw.dlog(f"Boot after {boot_after_ms} ms | Boot timeout {boot_timeout_ms} ms")

View File

@ -131,8 +131,7 @@ def pack_scex_cmds(p: ServiceProviderParams): # noqa C901
cell_select = int(cell_select) cell_select = int(cell_select)
if cell_select < 1 or cell_select > 10: if cell_select < 1 or cell_select > 10:
print( print(
f"Invalid cell number {cell_select}, " f"Invalid cell number {cell_select}, Please enter a valid number: "
f"Please enter a valid number: "
) )
continue continue
cn = cell_select - 1 cn = cell_select - 1

View File

@ -200,7 +200,8 @@ def pack_common_gomspace_cmds( # noqa C901: Complexity is okay here.
if op_code in GomspaceOpCode.SAVE_TABLE_DEFAULT: if op_code in GomspaceOpCode.SAVE_TABLE_DEFAULT:
source_table = int( source_table = int(
input( input(
"Source table [0: Board Config, 1: Module Config, 2: Calibration Parameter]: " "Source table [0: Board Config, 1: Module Config, 2: Calibration"
" Parameter]: "
) )
) )
if source_table not in [0, 1, 2]: if source_table not in [0, 1, 2]:
@ -215,8 +216,8 @@ def pack_common_gomspace_cmds( # noqa C901: Complexity is okay here.
if op_code in GomspaceOpCode.LOAD_TABLE: if op_code in GomspaceOpCode.LOAD_TABLE:
target_table = int( target_table = int(
input( input(
"Target table ID [0: Board Config, 1: Module Config, 2: Calibration Parameter, " "Target table ID [0: Board Config, 1: Module Config, 2: Calibration"
"4: HK TM]: " " Parameter, 4: HK TM]: "
) )
) )
if target_table not in [0, 1, 2, 4]: if target_table not in [0, 1, 2, 4]:

View File

@ -284,7 +284,7 @@ def hpa_on_procedure(q: DefaultPusQueueHelper):
if delay_dro_to_x8 is None: if delay_dro_to_x8 is None:
delay_dro_to_x8 = 900 delay_dro_to_x8 = 900
q.add_log_cmd( q.add_log_cmd(
f"Starting procedure to switch on PL PCDU HPA with DRO to X8 " "Starting procedure to switch on PL PCDU HPA with DRO to X8 "
f"delay of {delay_dro_to_x8} seconds" f"delay of {delay_dro_to_x8} seconds"
) )
pl_pcdu_on = PusTelecommand( pl_pcdu_on = PusTelecommand(

View File

@ -75,8 +75,8 @@ class WdtInfo:
self.pw.dlog(wdt_info) self.pw.dlog(wdt_info)
for idx in range(len(self.wdt_reboots_list)): for idx in range(len(self.wdt_reboots_list)):
self.pw.dlog( self.pw.dlog(
f"{WDT_LIST[idx].ljust(5)} | " f"{WDT_LIST[idx].ljust(5)} | {self.wdt_reboots_list[idx]:010} |"
f"{self.wdt_reboots_list[idx]:010} | {self.time_pings_left_list[idx]:010}", f" {self.time_pings_left_list[idx]:010}",
) )
def parse(self, wdt_data: bytes, current_idx: int) -> int: def parse(self, wdt_data: bytes, current_idx: int) -> int:
@ -328,7 +328,8 @@ def handle_p60_hk_data(pw: PrintWrapper, set_id: int, hk_data: bytes):
pw.dlog(misc_info) pw.dlog(misc_info)
batt_info = ( batt_info = (
f"Batt Temp 0 {batt_temp_0 / 10.0} | Batt Temp 1 {batt_temp_1 / 10.0} |" f"Batt Temp 0 {batt_temp_0 / 10.0} | Batt Temp 1 {batt_temp_1 / 10.0} |"
f"Charge Current {batt_charge_current} | Discharge Current {batt_discharge_current}" f" Charge Current {batt_charge_current} | Discharge Current"
f" {batt_discharge_current}"
) )
pw.dlog(batt_info) pw.dlog(batt_info)
pw.dlog( pw.dlog(
@ -419,12 +420,12 @@ def handle_acu_hk_data(pw: PrintWrapper, set_id: int, hk_data: bytes):
) )
pw.dlog(f"Boot Cause {boot_cause} | Reset Cause {reset_cause}") pw.dlog(f"Boot Cause {boot_cause} | Reset Cause {reset_cause}")
pw.dlog( pw.dlog(
f"Ground WDT: Reboot Count {wdt_cnt_gnd} | Time Left {wdt_gnd_time_left} sec" f"Ground WDT: Reboot Count {wdt_cnt_gnd} | Time Left"
f" {wdt_gnd_time_left} sec"
) )
pw.dlog( pw.dlog(
"ACU Dev Types: 0:FRAM|1:ADC|2:ADC|3:DAC|4:DAC|" "ACU Dev Types: 0:FRAM|1:ADC|2:ADC|3:DAC|4:DAC|5:DAC|6:TempSens|7:Reserved"
"5:DAC|6:TempSens|7:Reserved"
) )
dev_parser.print(pw=pw) dev_parser.print(pw=pw)
FsfwTmTcPrinter.get_validity_buffer( FsfwTmTcPrinter.get_validity_buffer(
@ -474,7 +475,8 @@ def pdu_config_table_handler(
pw.dlog("[tcs, syrlinks, str, mgt, sus-n, scex, ploc, acs-a, unused]") pw.dlog("[tcs, syrlinks, str, mgt, sus-n, scex, ploc, acs-a, unused]")
elif obj_id.as_bytes == PDU_2_HANDLER_ID: elif obj_id.as_bytes == PDU_2_HANDLER_ID:
pw.dlog( pw.dlog(
"[obc, pl-pcdu-bat-nom, rw, heaters, sus-r, sa-depl, pl-pcdu-bat-red, acs-b, pl-cam]" "[obc, pl-pcdu-bat-nom, rw, heaters, sus-r, sa-depl, pl-pcdu-bat-red,"
" acs-b, pl-cam]"
) )
out_on_cnt = unpack_array_in_data(custom_data, 0x52, 2, 9, "H") out_on_cnt = unpack_array_in_data(custom_data, 0x52, 2, 9, "H")
out_off_cnt = unpack_array_in_data(custom_data, 0x64, 2, 9, "H") out_off_cnt = unpack_array_in_data(custom_data, 0x64, 2, 9, "H")

View File

@ -12,8 +12,8 @@ from tmtccmd.tc.pus_3_fsfw_hk import (
make_sid, make_sid,
generate_one_hk_command, generate_one_hk_command,
create_request_one_diag_command, create_request_one_diag_command,
create_enable_periodic_hk_command_with_interval,
create_request_one_hk_command, create_request_one_hk_command,
create_enable_periodic_hk_command_with_interval_with_diag,
) )
@ -68,7 +68,7 @@ def pack_tcs_ctrl_commands(q: DefaultPusQueueHelper, op_code: str):
) )
if op_code == OpCode.ENABLE_TEMP_SET: if op_code == OpCode.ENABLE_TEMP_SET:
interval_seconds = float(input("Please specify interval in seconds: ")) interval_seconds = float(input("Please specify interval in seconds: "))
cmds = create_enable_periodic_hk_command_with_interval( cmds = create_enable_periodic_hk_command_with_interval_with_diag(
False, make_sid(TCS_CONTROLLER, CtrlSetId.PRIMARY_SENSORS), interval_seconds False, make_sid(TCS_CONTROLLER, CtrlSetId.PRIMARY_SENSORS), interval_seconds
) )
for cmd in cmds: for cmd in cmds:

View File

@ -148,8 +148,8 @@ def time_prompt_offset_from_now() -> datetime.datetime:
seconds_offset = math.floor( seconds_offset = math.floor(
float( float(
input( input(
"Please enter the time as a offset from now in seconds. Negative offset is " "Please enter the time as a offset from now in seconds. Negative offset"
"allowed: " " is allowed: "
) )
) )
) )

View File

@ -32,8 +32,8 @@ def main():
if not os.path.exists("setup.cfg"): if not os.path.exists("setup.cfg"):
additional_flags_second_step += " --max-line-length=100" additional_flags_second_step += " --max-line-length=100"
flake8_second_step_cmd = ( flake8_second_step_cmd = (
f"{python_exe} flake8 . {additional_flags_both_steps} {additional_flags_second_step}" f"{python_exe} flake8 . {additional_flags_both_steps} "
f" {exclude_dirs_flag}" f" {additional_flags_second_step} {exclude_dirs_flag}"
) )
os.system(flake8_second_step_cmd) os.system(flake8_second_step_cmd)

View File

@ -6,7 +6,7 @@ build-backend = "setuptools.build_meta"
name = "eive-tmtc" name = "eive-tmtc"
description = "TMTC Commander EIVE" description = "TMTC Commander EIVE"
readme = "README.md" readme = "README.md"
dynamic = ["version"] version = "5.5.1"
requires-python = ">=3.10" requires-python = ">=3.10"
license = {text = "Apache-2.0"} license = {text = "Apache-2.0"}
authors = [ authors = [
@ -29,7 +29,7 @@ classifiers = [
"Topic :: Scientific/Engineering" "Topic :: Scientific/Engineering"
] ]
dependencies = [ dependencies = [
# "tmtccmd ~= 5.0", # "tmtccmd == 6.0.0rc0",
"python-dateutil ~= 2.8", "python-dateutil ~= 2.8",
"tmtccmd @ git+https://github.com/robamu-org/tmtccmd@main" "tmtccmd @ git+https://github.com/robamu-org/tmtccmd@main"
] ]
@ -40,9 +40,6 @@ dependencies = [
[tool.setuptools] [tool.setuptools]
include-package-data = true include-package-data = true
[tool.setuptools.dynamic]
version = {attr = "eive_tmtc.__version__"}
# Auto-Discovery is problematic for some reason, so use custom-discovery # Auto-Discovery is problematic for some reason, so use custom-discovery
[tool.setuptools.packages] [tool.setuptools.packages]
find = {} find = {}

View File

@ -3,7 +3,7 @@ Checklist for new releases
# Pre-Release # Pre-Release
1. Bump version inside the `eive_tmtc/__init__.py` file. 1. Bump version inside the `pyproject.toml` file.
2. Update `CHANGELOG.md`: Convert `unreleased` section into version section 2. Update `CHANGELOG.md`: Convert `unreleased` section into version section
with date and new `unreleased`section. with date and new `unreleased`section.
3. Run auto-formatter with `black .` 3. Run auto-formatter with `black .`

View File

@ -2,13 +2,14 @@
import logging import logging
import sys import sys
import time import time
import traceback
from pathlib import Path from pathlib import Path
import tmtccmd
from eive_tmtc.cfdp.fault_handler import EiveCfdpFaultHandler from eive_tmtc.cfdp.fault_handler import EiveCfdpFaultHandler
from eive_tmtc.cfdp.tm import CfdpInCcsdsWrapper from eive_tmtc.cfdp.tm import CfdpInCcsdsWrapper
from eive_tmtc.cfdp.user import EiveCfdpUser from eive_tmtc.cfdp.user import EiveCfdpUser
from spacepackets.version import get_version as get_spacepackets_version from spacepackets.ecss import PusVerificator
from spacepackets.version import get_version as get_sp_version
from spacepackets.cfdp import ( from spacepackets.cfdp import (
ChecksumType, ChecksumType,
TransmissionMode, TransmissionMode,
@ -22,28 +23,6 @@ from tmtccmd.cfdp.mib import (
IndicationCfg, IndicationCfg,
RemoteEntityCfg, RemoteEntityCfg,
) )
try:
import spacepackets
except ImportError as error:
print(error)
print("Python spacepackets module could not be imported")
print(
'Install with "cd spacepackets && python3 -m pip intall -e ." for interative installation'
)
sys.exit(1)
try:
import tmtccmd
except ImportError:
run_tmtc_commander = None
initialize_tmtc_commander = None
tb = traceback.format_exc()
print(tb)
print("Python tmtccmd submodule could not be imported")
sys.exit(1)
from spacepackets.ecss import PusVerificator
from tmtccmd import BackendBase from tmtccmd import BackendBase
from tmtccmd.util import FileSeqCountProvider, PusFileSeqCountProvider from tmtccmd.util import FileSeqCountProvider, PusFileSeqCountProvider
from tmtccmd.fsfw.tmtc_printer import FsfwTmTcPrinter from tmtccmd.fsfw.tmtc_printer import FsfwTmTcPrinter
@ -67,7 +46,7 @@ from tmtccmd.config.args import (
ProcedureParamsWrapper, ProcedureParamsWrapper,
) )
from eive_tmtc import APP_LOGGER from eive_tmtc import APP_LOGGER
from eive_tmtc import __version__ from importlib.metadata import version
from eive_tmtc.config.definitions import ( from eive_tmtc.config.definitions import (
PUS_APID, PUS_APID,
CFDP_APID, CFDP_APID,
@ -241,8 +220,8 @@ def setup_backend(
def main(): # noqa C901: Complexity okay here. def main(): # noqa C901: Complexity okay here.
print(f"-- eive tmtc v{__version__} --") print(f"-- eive tmtc v{version('eive-tmtc')} --")
print(f"-- spacepackets v{get_spacepackets_version()} --") print(f"-- spacepackets v{get_sp_version()} --")
add_colorlog_console_logger(_LOGGER) add_colorlog_console_logger(_LOGGER)
# TODO: -V CLI argument to enable this? # TODO: -V CLI argument to enable this?
_LOGGER.setLevel(_LOG_LEVEL) _LOGGER.setLevel(_LOG_LEVEL)