some more cleaning and set ID updates

This commit is contained in:
Robin Müller 2022-10-18 11:01:01 +02:00
parent 195d5343bc
commit 9171f23d93
7 changed files with 38 additions and 34 deletions

View File

@ -31,17 +31,6 @@ class GomspaceDeviceActionIds(enum.IntEnum):
PRINT_LATCHUPS = 33
class SetIds:
PDU_1_CORE = 1
PDU_1_AUX = 2
PDU_2_CORE = 3
PDU_2_AUX = 4
P60_CORE = 5
P60_AUX = 6
ACU_CORE = 7
ACU_AUX = 8
class ParamTypes(enum.Enum):
U8 = 0
U16 = 1

View File

@ -22,15 +22,13 @@ import config.object_ids as oids
from pus_tc.system.tcs import OpCodes as TcsOpCodes
from pus_tc.devs.bpx_batt import BpxSetIds
from pus_tc.system.core import SetIds as CoreSetIds
from gomspace.gomspace_common import SetIds as GsSetIds
from tmtc.power.common_power import SetIds as GsSetIds
from pus_tc.devs.rad_sensor import SetIds as RadSetIds
from pus_tc.devs.mgms import MgmLis3SetIds as MgmLis3SetIds_0_2
from pus_tc.devs.mgms import MgmRm3100SetIds as MgmRm3100SetIds_1_3
from pus_tc.devs.gyros import AdisGyroSetIds as AdisGyroSetIds_0_2
from pus_tc.devs.gyros import L3gGyroSetIds as L3gGyroSetIds_1_3
from pus_tc.devs.syrlinks_hk_handler import OpCodes as SyrlinksOpCodes
from pus_tc.devs.syrlinks_hk_handler import SetIds as SyrlinksSetIds
from pus_tc.devs.star_tracker import OpCodes as StrOpCodes
from pus_tc.devs.gps import SetIds as GpsSetIds
from pus_tc.devs.imtq import ImtqSetIds
from pus_tc.devs.sus import SetIds
@ -247,14 +245,14 @@ def pack_proc_commands(q: DefaultPusQueueHelper, op_code: str):
if op_code in OpCodes.PCDU_FT:
key = KAI.PCDU_FT[0]
pcdu_pairs = [
(oids.P60_DOCK_HANDLER, GsSetIds.P60_CORE),
(oids.PDU_1_HANDLER_ID, GsSetIds.PDU_1_CORE),
(oids.PDU_2_HANDLER_ID, GsSetIds.PDU_2_CORE),
(oids.ACU_HANDLER_ID, GsSetIds.ACU_CORE),
(oids.P60_DOCK_HANDLER, GsSetIds.P60_AUX),
(oids.PDU_1_HANDLER_ID, GsSetIds.PDU_1_AUX),
(oids.PDU_2_HANDLER_ID, GsSetIds.PDU_2_AUX),
(oids.ACU_HANDLER_ID, GsSetIds.ACU_AUX),
(oids.P60_DOCK_HANDLER, GsSetIds.CORE),
(oids.PDU_1_HANDLER_ID, GsSetIds.CORE),
(oids.PDU_2_HANDLER_ID, GsSetIds.CORE),
(oids.ACU_HANDLER_ID, GsSetIds.CORE),
(oids.P60_DOCK_HANDLER, GsSetIds.AUX),
(oids.PDU_1_HANDLER_ID, GsSetIds.AUX),
(oids.PDU_2_HANDLER_ID, GsSetIds.AUX),
(oids.ACU_HANDLER_ID, GsSetIds.AUX),
]
diag_list = [
@ -587,10 +585,10 @@ def pack_proc_commands(q: DefaultPusQueueHelper, op_code: str):
]
# HK listening
pack_generic_hk_listening_cmds(
tc_queue=tc_queue,
q=q,
proc_key=key,
sid_list=sid_list,
diag=False,
diag_list=[False],
cfg=GenericHkListeningCfg.default(),
)
if op_code in OpCodes.STR_FT:
@ -726,7 +724,7 @@ def enable_listen_to_hk_for_x_seconds(
):
q.add_log_cmd(f"Enabling periodic HK for {device}")
cmd_tuple = enable_periodic_hk_command_with_interval(
diag=diag, sid=sid, interval_seconds=interval_seconds, ssc=0
diag=diag, sid=sid, interval_seconds=interval_seconds
)
for cmd in cmd_tuple:
q.add_pus_tc(cmd)

View File

@ -10,6 +10,7 @@ from tmtc.power.common_power import (
add_gomspace_cmd_defs,
req_hk_cmds,
pack_common_power_cmds,
SetIds,
)
from tmtccmd.config import TmtcDefinitionWrapper, OpCodeEntry
from tmtccmd.config.tmtc import tmtc_definitions_provider
@ -67,9 +68,7 @@ def pack_acu_commands(object_id: ObjectIdU32, q: DefaultPusQueueHelper, op_code:
def acu_req_hk_cmds(q: DefaultPusQueueHelper, op_code: str):
req_hk_cmds(
"ACU", q, op_code, ACU_HANDLER_ID, [gs.SetIds.ACU_CORE, gs.SetIds.ACU_AUX]
)
req_hk_cmds("ACU", q, op_code, ACU_HANDLER_ID, [SetIds.CORE, SetIds.AUX])
class ACUTestProcedure:

View File

@ -16,6 +16,8 @@ from tmtccmd.tc.pus_3_fsfw_hk import (
make_sid,
generate_one_diag_command,
generate_one_hk_command,
enable_periodic_hk_command_with_interval,
disable_periodic_hk_command,
)
from tmtccmd.tc.pus_8_funccmd import make_fsfw_action_cmd
from tmtccmd.util import ObjectIdU32, ObjectIdBase
@ -104,12 +106,27 @@ class PowerOpCodes:
PRINT_LATCHUPS = ["print_latchups"]
class SetIds:
CORE = 1
AUX = 2
CONFIG = 3
def pack_common_power_cmds(
prefix: str, object_id: ObjectIdU32, q: DefaultPusQueueHelper, op_code: str
):
objb = object_id.as_bytes
if op_code in PowerOpCodes.ENABLE_INFO_HK:
pass
interval = float(input("Specify HK interval in floating point seconds: "))
q.add_log_cmd(f"{prefix}: {PowerInfo.ENABLE_INFO_HK} with interval {interval}")
cmds = enable_periodic_hk_command_with_interval(
True, make_sid(objb, SetIds.CORE), interval
)
for cmd in cmds:
q.add_pus_tc(cmd)
if op_code in PowerOpCodes.DISABLE_INFO_HK:
q.add_log_cmd(f"{prefix}: {PowerInfo.DISABLE_INFO_HK}")
q.add_pus_tc(disable_periodic_hk_command(True, make_sid(objb, SetIds.CORE)))
def pack_common_gomspace_cmds(

View File

@ -66,7 +66,7 @@ class PDU1TestProcedure:
def pack_pdu1_commands(object_id: ObjectIdU32, q: DefaultPusQueueHelper, op_code: str):
q.add_log_cmd("Commanding PDU1")
objb = object_id.as_bytes
pdu1_cmds(q, op_code)
pdu1_switch_cmds(q, op_code)
pdu1_req_hk_cmds(q, op_code)
pack_common_power_cmds("PDU1", object_id, q, op_code)
pack_common_gomspace_cmds("PDU1", object_id, q, op_code)
@ -100,7 +100,7 @@ def info_off_pdu1(base: str) -> str:
return "PDU1: " + base + " off"
def pdu1_cmds(q: DefaultPusQueueHelper, op_code: str):
def pdu1_switch_cmds(q: DefaultPusQueueHelper, op_code: str):
if op_code in PowerOpCodes.TCS_ON:
tcs_on_cmd(q)
elif op_code in PowerOpCodes.TCS_OFF:

View File

@ -14,7 +14,7 @@ from config.object_ids import (
)
from tmtc.power.pdu1 import (
pdu1_req_hk_cmds,
pdu1_cmds,
pdu1_switch_cmds,
add_pdu1_common_defs,
add_pdu1_cmds,
)
@ -37,7 +37,7 @@ LOGGER = get_console_logger()
def pack_power_commands(q: DefaultPusQueueHelper, op_code: str):
pdu1_cmds(q, op_code)
pdu1_switch_cmds(q, op_code)
pdu2_cmds(q, op_code)
if op_code in PowerOpCodes.INFO_CORE:
pdu1_req_hk_cmds(q, PowerOpCodes.REQUEST_CORE_HK_ONCE[0])

View File

@ -1,10 +1,11 @@
import struct
from typing import List, Tuple
from tmtc.power.common_power import SetIds
from tmtccmd.util import ObjectIdBase
from tmtccmd.util.tmtc_printer import FsfwTmTcPrinter
from pus_tm.defs import PrintWrapper
from gomspace.gomspace_common import SetIds, GomspaceDeviceActionIds
from gomspace.gomspace_common import GomspaceDeviceActionIds
from config.object_ids import (
PDU_1_HANDLER_ID,
PDU_2_HANDLER_ID,