This commit is contained in:
parent
0b8bd61e80
commit
d73ef3a314
@ -1,7 +1,6 @@
|
||||
"""HK Handling for EIVE OBSW"""
|
||||
import logging
|
||||
|
||||
# from pus_tm.tcp_server_objects import TCP_SEVER_SENSOR_TEMPERATURES
|
||||
from eive_tmtc.tmtc.acs.acs_ctrl import handle_acs_ctrl_hk_data
|
||||
from eive_tmtc.tmtc.internal_err_reporter import handle_ier_hk_data
|
||||
from eive_tmtc.tmtc.payload.ploc_mpsoc import handle_ploc_mpsoc_hk_data
|
||||
@ -56,18 +55,14 @@ def handle_hk_packet(
|
||||
named_obj_id = tm_packet.object_id
|
||||
if tm_packet.subservice == 25 or tm_packet.subservice == 26:
|
||||
hk_data = tm_packet.tm_data[8:]
|
||||
if FORWARD_SENSOR_TEMPS:
|
||||
# TODO: Maybe use singleton?
|
||||
# TCP_SEVER_SENSOR_TEMPERATURES.report_raw_hk_data(
|
||||
# object_id=named_obj_id, set_id=tm_packet.set_id, hk_data=hk_data
|
||||
# )
|
||||
pass
|
||||
|
||||
printer.generic_hk_tm_print(
|
||||
content_type=HkContentType.HK,
|
||||
object_id=named_obj_id,
|
||||
set_id=tm_packet.set_id,
|
||||
hk_data=hk_data,
|
||||
)
|
||||
|
||||
try:
|
||||
if hk_level == 1:
|
||||
pass
|
@ -18,7 +18,7 @@ from .defs import PrintWrapper
|
||||
|
||||
from .event_handler import handle_event_packet
|
||||
from .verification_handler import handle_service_1_fsfw_packet, generic_retval_printout
|
||||
from .hk_handling import handle_hk_packet
|
||||
from .hk_demux import handle_hk_packet
|
||||
from .action_reply_handler import handle_action_reply
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
@ -442,10 +442,7 @@ def pack_star_tracker_commands( # noqa C901
|
||||
q.add_pus_tc(PusTelecommand(service=8, subservice=128, app_data=data))
|
||||
if op_code == OpCodes.SET_TIME_FROM_SYS_TIME:
|
||||
q.add_log_cmd(Info.SET_TIME_FROM_SYS_TIME)
|
||||
data = (
|
||||
obyt
|
||||
+ struct.pack("!I", StarTrackerActionId.SET_TIME_FROM_SYS_TIME)
|
||||
)
|
||||
data = obyt + struct.pack("!I", StarTrackerActionId.SET_TIME_FROM_SYS_TIME)
|
||||
q.add_pus_tc(PusTelecommand(service=8, subservice=128, app_data=data))
|
||||
if op_code == "39":
|
||||
q.add_log_cmd("Star tracker: Download Centroid")
|
||||
|
@ -20,7 +20,7 @@ from eive_tmtc.config.object_ids import (
|
||||
TMP1075_HANDLER_PLPCDU_1_ID,
|
||||
TMP1075_HANDLER_IF_BRD_ID,
|
||||
STR_ASSEMBLY,
|
||||
STAR_TRACKER_ID
|
||||
STAR_TRACKER_ID,
|
||||
)
|
||||
|
||||
SUBSYSTEM_DICT = {
|
||||
@ -45,7 +45,7 @@ ACS_OBJ_DICT = {
|
||||
12: ("SUS 6", SUS_6_R_LOC_XFYBZM_PT_XF),
|
||||
13: ("RW 1", RW1_ID),
|
||||
14: ("RW 2", RW2_ID),
|
||||
15: ("STR", STAR_TRACKER_ID)
|
||||
15: ("STR", STAR_TRACKER_ID),
|
||||
}
|
||||
|
||||
TCS_OBJ_DICT = {
|
||||
|
Loading…
Reference in New Issue
Block a user