added mode commanding for radiation sensor
This commit is contained in:
parent
7a15062efe
commit
fe1bed900a
@ -27,3 +27,4 @@ class CustomServiceList(enum.Enum):
|
||||
REACTION_WHEEL_2 = "reaction_wheel_2"
|
||||
REACTION_WHEEL_3 = "reaction_wheel_3"
|
||||
REACTION_WHEEL_4 = "reaction_wheel_4"
|
||||
RAD_SENSOR = "rad_sensor"
|
||||
|
@ -74,6 +74,13 @@ class EiveHookObject(TmTcHookBase):
|
||||
}
|
||||
service_rw_tuple = ("Reaction Wheel", op_code_dict_srv_rw)
|
||||
|
||||
op_code_dict_srv_rad_sensor = {
|
||||
"0": ("Radiation Sensor: Set mode on", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"1": ("Radiation Sensor: Set mode normal", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"2": ("Radiation Sensor: Set mode off", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
}
|
||||
service_rad_sensor_tuple = ("Radiation Sensor", op_code_dict_srv_rad_sensor)
|
||||
|
||||
service_op_code_dict[CustomServiceList.ACU.value] = service_acu_tuple
|
||||
service_op_code_dict[CustomServiceList.TMP1075_1.value] = service_tmp1075_1_tuple
|
||||
service_op_code_dict[CustomServiceList.TMP1075_2.value] = service_tmp1075_2_tuple
|
||||
@ -86,6 +93,7 @@ class EiveHookObject(TmTcHookBase):
|
||||
service_op_code_dict[CustomServiceList.REACTION_WHEEL_2.value] = service_rw_tuple
|
||||
service_op_code_dict[CustomServiceList.REACTION_WHEEL_3.value] = service_rw_tuple
|
||||
service_op_code_dict[CustomServiceList.REACTION_WHEEL_4.value] = service_rw_tuple
|
||||
service_op_code_dict[CustomServiceList.RAD_SENSOR.value] = service_rad_sensor_tuple
|
||||
return service_op_code_dict
|
||||
|
||||
def get_json_config_file_path(self) -> str:
|
||||
|
@ -23,6 +23,8 @@ RW1_ID = bytes([0x44, 0x21, 0x00, 0x1])
|
||||
RW2_ID = bytes([0x44, 0x21, 0x00, 0x2])
|
||||
RW3_ID = bytes([0x44, 0x21, 0x00, 0x3])
|
||||
RW4_ID = bytes([0x44, 0x21, 0x00, 0x4])
|
||||
RAD_SENSOR_ID = bytes([0x44, 0x32, 0x00, 0xA5])
|
||||
|
||||
|
||||
def get_object_ids() -> Dict[bytes, list]:
|
||||
object_id_dict = ({
|
||||
@ -41,5 +43,6 @@ def get_object_ids() -> Dict[bytes, list]:
|
||||
RW2_ID: "Reaction Wheel 2",
|
||||
RW3_ID: "Reaction Wheel 3",
|
||||
RW4_ID: "Reaction Wheel 4",
|
||||
RAD_SENSOR_ID: "Radiation Sensor",
|
||||
})
|
||||
return object_id_dict
|
||||
|
38
pus_tc/rad_sensor.py
Normal file
38
pus_tc/rad_sensor.py
Normal file
@ -0,0 +1,38 @@
|
||||
# -*- coding: utf-8 -*-
|
||||
"""
|
||||
@file rad_sensor.py
|
||||
@brief Tests for the radiation sensor handler
|
||||
@author J. Meier
|
||||
@date 01.07.2021
|
||||
"""
|
||||
import struct
|
||||
from tmtccmd.config.definitions import QueueCommands
|
||||
|
||||
from tmtccmd.pus_tc.packer import TcQueueT
|
||||
from tmtccmd.ecss.tc import PusTelecommand
|
||||
from pus_tc.service_200_mode import pack_mode_data
|
||||
|
||||
|
||||
def pack_rad_sensor_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code: str) -> TcQueueT:
|
||||
tc_queue.appendleft(
|
||||
(QueueCommands.PRINT,
|
||||
"Testing radiation sensor handler with object id: 0x" + object_id.hex())
|
||||
)
|
||||
|
||||
if op_code == "0":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "Rad sensor: Switch to mode on"))
|
||||
mode_data = pack_mode_data(object_id, 1, 0)
|
||||
command = PusTelecommand(service=200, subservice=1, ssc=41, app_data=mode_data)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "1":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "Rad sensor: Switch to mode normal"))
|
||||
mode_data = pack_mode_data(object_id, 2, 0)
|
||||
command = PusTelecommand(service=200, subservice=1, ssc=42, app_data=mode_data)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "2":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "Rad sensor: Switch to mode off"))
|
||||
mode_data = pack_mode_data(object_id, 0, 0)
|
||||
command = PusTelecommand(service=200, subservice=1, ssc=42, app_data=mode_data)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
@ -1,9 +1,9 @@
|
||||
# -*- coding: utf-8 -*-
|
||||
"""
|
||||
@file imtq.py
|
||||
@brief Tests for the ISIS IMTQ (Magnettorquer) device handler
|
||||
@file reaction_wheels.py
|
||||
@brief Tests for the reaction wheel handler
|
||||
@author J. Meier
|
||||
@date 25.03.2021
|
||||
@date 20.06.2021
|
||||
"""
|
||||
import struct
|
||||
from tmtccmd.config.definitions import QueueCommands
|
||||
@ -11,7 +11,6 @@ from tmtccmd.config.definitions import QueueCommands
|
||||
from tmtccmd.pus_tc.packer import TcQueueT
|
||||
from tmtccmd.ecss.tc import PusTelecommand
|
||||
from pus_tc.service_200_mode import pack_mode_data
|
||||
from tmtccmd.pus_tc.service_3_housekeeping import make_sid, generate_one_hk_command
|
||||
|
||||
|
||||
class RwSetIds:
|
||||
|
@ -23,9 +23,11 @@ from pus_tc.tmp1075 import pack_tmp1075_test_into
|
||||
from pus_tc.ploc import pack_ploc_test_into
|
||||
from pus_tc.heater import pack_heater_test_into
|
||||
from pus_tc.reaction_wheels import pack_single_rw_test_into
|
||||
from pus_tc.rad_sensor import pack_rad_sensor_test_into
|
||||
from config.definitions import CustomServiceList
|
||||
from config.object_ids import P60_DOCK_HANDLER, PDU_1_HANDLER_ID, PDU_2_HANDLER_ID, ACU_HANDLER_ID, \
|
||||
TMP_1075_1_HANDLER_ID, TMP_1075_2_HANDLER_ID, HEATER_ID, IMTQ_HANDLER_ID, PLOC_ID, RW1_ID, RW2_ID, RW3_ID, RW4_ID
|
||||
TMP_1075_1_HANDLER_ID, TMP_1075_2_HANDLER_ID, HEATER_ID, IMTQ_HANDLER_ID, PLOC_ID, RW1_ID, RW2_ID, RW3_ID, RW4_ID, \
|
||||
RAD_SENSOR_ID
|
||||
|
||||
|
||||
LOGGER = get_console_logger()
|
||||
@ -81,6 +83,9 @@ def pack_service_queue_user(service: Union[str, int], op_code: str, service_queu
|
||||
if service == CustomServiceList.REACTION_WHEEL_4.value:
|
||||
object_id = RW4_ID
|
||||
return pack_single_rw_test_into(object_id=object_id, tc_queue=service_queue, op_code=op_code)
|
||||
if service == CustomServiceList.RAD_SENSOR.value:
|
||||
object_id = RAD_SENSOR_ID
|
||||
return pack_rad_sensor_test_into(object_id=object_id, tc_queue=service_queue, op_code=op_code)
|
||||
|
||||
LOGGER.warning("Invalid Service !")
|
||||
|
||||
|
Loading…