Compare commits

..

1 Commits

Author SHA1 Message Date
0a47c17fa6 bump tmtccmd 2022-05-02 12:53:01 +02:00
9 changed files with 67 additions and 199 deletions

View File

@@ -80,6 +80,7 @@
11300;0x2c24;SWITCH_CMD_SENT;INFO;Indicates that a FSFW object requested setting a switch P1: 1 if on was requested, 0 for off | P2: Switch Index;mission/devices/devicedefinitions/powerDefinitions.h
11301;0x2c25;SWITCH_HAS_CHANGED;INFO;Indicated that a swithc state has changed P1: New switch state, 1 for on, 0 for off | P2: Switch Index;mission/devices/devicedefinitions/powerDefinitions.h
11302;0x2c26;SWITCHING_Q7S_DENIED;MEDIUM;;mission/devices/devicedefinitions/powerDefinitions.h
11303;0x2c27;FDIR_REACTION_IGNORED;MEDIUM;;mission/devices/devicedefinitions/powerDefinitions.h
11400;0x2c88;GPIO_PULL_HIGH_FAILED;LOW;;mission/devices/HeaterHandler.h
11401;0x2c89;GPIO_PULL_LOW_FAILED;LOW;;mission/devices/HeaterHandler.h
11402;0x2c8a;SWITCH_ALREADY_ON;LOW;;mission/devices/HeaterHandler.h
1 2200 0x0898 STORE_SEND_WRITE_FAILED LOW fsfw/src/fsfw/tmstorage/TmStoreBackendIF.h
80 11300 0x2c24 SWITCH_CMD_SENT INFO Indicates that a FSFW object requested setting a switch P1: 1 if on was requested, 0 for off | P2: Switch Index mission/devices/devicedefinitions/powerDefinitions.h
81 11301 0x2c25 SWITCH_HAS_CHANGED INFO Indicated that a swithc state has changed P1: New switch state, 1 for on, 0 for off | P2: Switch Index mission/devices/devicedefinitions/powerDefinitions.h
82 11302 0x2c26 SWITCHING_Q7S_DENIED MEDIUM mission/devices/devicedefinitions/powerDefinitions.h
83 11303 0x2c27 FDIR_REACTION_IGNORED MEDIUM mission/devices/devicedefinitions/powerDefinitions.h
84 11400 0x2c88 GPIO_PULL_HIGH_FAILED LOW mission/devices/HeaterHandler.h
85 11401 0x2c89 GPIO_PULL_LOW_FAILED LOW mission/devices/HeaterHandler.h
86 11402 0x2c8a SWITCH_ALREADY_ON LOW mission/devices/HeaterHandler.h

View File

@@ -622,36 +622,18 @@ def add_ploc_supv_cmds(cmd_dict: ServiceOpCodeDictT):
{OpCodeDictKeys.TIMEOUT: 2.0},
),
"42": ("PLOC Supervisor: Perform update", {OpCodeDictKeys.TIMEOUT: 2.0}),
"43": (
"PLOC Supervisor: Terminate supervisor process",
{OpCodeDictKeys.TIMEOUT: 2.0},
),
"43": ("PLOC Supervisor: Terminate supervisor process", {OpCodeDictKeys.TIMEOUT: 2.0}),
"44": ("PLOC Supervisor: Start MPSoC quiet", {OpCodeDictKeys.TIMEOUT: 2.0}),
"45": ("PLOC Supervisor: Set shutdown timeout", {OpCodeDictKeys.TIMEOUT: 2.0}),
"46": ("PLOC Supervisor: Factory flash", {OpCodeDictKeys.TIMEOUT: 2.0}),
"47": ("PLOC Supervisor: Enable auto TM", {OpCodeDictKeys.TIMEOUT: 2.0}),
"48": ("PLOC Supervisor: Disable auto TM", {OpCodeDictKeys.TIMEOUT: 2.0}),
"49": (
"PLOC Supervisor: Enable ADC monitor task",
{OpCodeDictKeys.TIMEOUT: 2.0},
),
"50": (
"PLOC Supervisor: Disable ADC monitor task",
{OpCodeDictKeys.TIMEOUT: 2.0},
),
"51": (
"PLOC Supervisor: Logging request event buffers",
{OpCodeDictKeys.TIMEOUT: 2.0},
),
"52": (
"PLOC Supervisor: Logging clear counters",
{OpCodeDictKeys.TIMEOUT: 2.0},
),
"49": ("PLOC Supervisor: Enable ADC monitor task", {OpCodeDictKeys.TIMEOUT: 2.0}),
"50": ("PLOC Supervisor: Disable ADC monitor task", {OpCodeDictKeys.TIMEOUT: 2.0}),
"51": ("PLOC Supervisor: Logging request event buffers", {OpCodeDictKeys.TIMEOUT: 2.0}),
"52": ("PLOC Supervisor: Logging clear counters", {OpCodeDictKeys.TIMEOUT: 2.0}),
"53": ("PLOC Supervisor: Logging set topic", {OpCodeDictKeys.TIMEOUT: 2.0}),
"54": (
"PLOC Supervisor: Logging request counters",
{OpCodeDictKeys.TIMEOUT: 2.0},
),
"54": ("PLOC Supervisor: Logging request counters", {OpCodeDictKeys.TIMEOUT: 2.0}),
"55": ("PLOC Supervisor: Request ADC Report", {OpCodeDictKeys.TIMEOUT: 2.0}),
"56": ("PLOC Supervisor: Reset PL", {OpCodeDictKeys.TIMEOUT: 2.0}),
}

View File

@@ -172,11 +172,7 @@ def pack_ploc_mpsoc_commands(
elif op_code == "16":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC MPSoC: Tc cam command send"))
cam_cmd = input("Specify cam command string: ")
command = (
object_id
+ struct.pack("!I", CommandIds.TC_CAM_CMD_SEND)
+ bytearray(cam_cmd, "utf-8")
)
command = object_id + struct.pack("!I", CommandIds.TC_CAM_CMD_SEND) + bytearray(cam_cmd, 'utf-8')
command = PusTelecommand(service=8, subservice=128, ssc=32, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())

View File

@@ -373,65 +373,69 @@ def pack_ploc_supv_commands(
command = PusTelecommand(service=8, subservice=128, ssc=57, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "43":
tc_queue.appendleft(
(QueueCommands.PRINT, "PLOC Supervisor: Terminate supervisor process")
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Terminate supervisor process"))
command = object_id + struct.pack(
"!I", SupvActionIds.TERMINATE_SUPV_HELPER
)
command = object_id + struct.pack("!I", SupvActionIds.TERMINATE_SUPV_HELPER)
command = PusTelecommand(service=8, subservice=128, ssc=58, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "44":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Start MPSoC quiet"))
command = object_id + struct.pack("!I", SupvActionIds.START_MPSOC_QUIET)
command = object_id + struct.pack(
"!I", SupvActionIds.START_MPSOC_QUIET
)
command = PusTelecommand(service=8, subservice=128, ssc=59, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "45":
tc_queue.appendleft(
(QueueCommands.PRINT, "PLOC Supervisor: Set shutdown timeout")
)
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set shutdown timeout"))
command = pack_set_shutdown_timeout_command(object_id)
command = PusTelecommand(service=8, subservice=128, ssc=60, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "46":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Factory flash"))
command = object_id + struct.pack("!I", SupvActionIds.FACTORY_FLASH)
command = object_id + struct.pack(
"!I", SupvActionIds.FACTORY_FLASH
)
command = PusTelecommand(service=8, subservice=128, ssc=61, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "47":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Enable auto TM"))
command = object_id + struct.pack("!I", SupvActionIds.ENABLE_AUTO_TM)
command = object_id + struct.pack(
"!I", SupvActionIds.ENABLE_AUTO_TM
)
command = PusTelecommand(service=8, subservice=128, ssc=62, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "48":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Disable auto TM"))
command = object_id + struct.pack("!I", SupvActionIds.DISABLE_AUTO_TM)
command = object_id + struct.pack(
"!I", SupvActionIds.DISABLE_AUTO_TM
)
command = PusTelecommand(service=8, subservice=128, ssc=63, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "49":
tc_queue.appendleft(
(QueueCommands.PRINT, "PLOC Supervisor: Enable ADC monitor task")
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Enable ADC monitor task"))
command = object_id + struct.pack(
"!I", SupvActionIds.ENABLE_ADC_MONITOR_TASK
)
command = object_id + struct.pack("!I", SupvActionIds.ENABLE_ADC_MONITOR_TASK)
command = PusTelecommand(service=8, subservice=128, ssc=64, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "50":
tc_queue.appendleft(
(QueueCommands.PRINT, "PLOC Supervisor: Disable ADC monitor task")
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Disable ADC monitor task"))
command = object_id + struct.pack(
"!I", SupvActionIds.DISABLE_ADC_MONITOR_TASK
)
command = object_id + struct.pack("!I", SupvActionIds.DISABLE_ADC_MONITOR_TASK)
command = PusTelecommand(service=8, subservice=128, ssc=65, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "51":
tc_queue.appendleft(
(QueueCommands.PRINT, "PLOC Supervisor: Logging request event buffers")
)
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Logging request event buffers"))
command = pack_logging_buffer_request(object_id)
command = PusTelecommand(service=8, subservice=128, ssc=66, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "52":
tc_queue.appendleft(
(QueueCommands.PRINT, "PLOC Supervisor: Logging clear counters")
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Logging clear counters"))
command = object_id + struct.pack(
"!I", SupvActionIds.LOGGING_CLEAR_COUNTERS
)
command = object_id + struct.pack("!I", SupvActionIds.LOGGING_CLEAR_COUNTERS)
command = PusTelecommand(service=8, subservice=128, ssc=67, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "53":
@@ -440,17 +444,13 @@ def pack_ploc_supv_commands(
command = PusTelecommand(service=8, subservice=128, ssc=68, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "54":
tc_queue.appendleft(
(QueueCommands.PRINT, "PLOC Supervisor: Logging request counters")
)
command = object_id + struct.pack("!I", SupvActionIds.LOGGING_REQUEST_COUNTERS)
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Logging request counters"))
command = object_id + struct.pack('!I', SupvActionIds.LOGGING_REQUEST_COUNTERS)
command = PusTelecommand(service=8, subservice=128, ssc=69, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "55":
tc_queue.appendleft(
(QueueCommands.PRINT, "PLOC Supervisor: Request ADC report")
)
command = object_id + struct.pack("!I", SupvActionIds.REQUEST_ADC_REPORT)
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Request ADC report"))
command = object_id + struct.pack('!I', SupvActionIds.REQUEST_ADC_REPORT)
command = PusTelecommand(service=8, subservice=128, ssc=70, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "56":
@@ -706,30 +706,30 @@ def pack_update_command(object_id: bytearray) -> bytearray:
start_address = int(input("Specify start address: 0x"), 16)
update_file = get_update_file()
command += object_id
command += struct.pack("!I", SupvActionIds.PERFORM_UPDATE)
command += bytearray(update_file, "utf-8")
command += struct.pack('!I', SupvActionIds.PERFORM_UPDATE)
command += bytearray(update_file, 'utf-8')
# Adding null terminator
command += struct.pack("!B", 0)
command += struct.pack("!B", memory_id)
command += struct.pack("!I", start_address)
command += struct.pack('!B', 0)
command += struct.pack('!B', memory_id)
command += struct.pack('!I', start_address)
return command
def pack_set_shutdown_timeout_command(object_id: bytearray) -> bytearray:
command = bytearray()
command += object_id
command += struct.pack("!I", SupvActionIds.SET_SHUTDOWN_TIMEOUT)
command += struct.pack('!I', SupvActionIds.SET_SHUTDOWN_TIMEOUT)
timeout = int(input("Specify shutdown timeout (ms): "))
command += struct.pack("!I", timeout)
command += struct.pack('!I', timeout)
return command
def pack_logging_buffer_request(object_id: bytearray) -> bytearray:
command = bytearray()
command += object_id
command += struct.pack("!I", SupvActionIds.LOGGING_REQUEST_EVENT_BUFFERS)
command += struct.pack('!I', SupvActionIds.LOGGING_REQUEST_EVENT_BUFFERS)
path = get_event_buffer_path()
command += bytearray(path, "utf-8")
command += bytearray(path, 'utf-8')
return command
@@ -779,9 +779,9 @@ def pack_read_gpio_cmd(object_id: bytearray) -> bytearray:
def pack_logging_set_topic(objetc_id: bytearray) -> bytearray:
command = objetc_id + struct.pack("!I", SupvActionIds.LOGGING_SET_TOPIC)
command = objetc_id + struct.pack('!I', SupvActionIds.LOGGING_SET_TOPIC)
tpc = int(input("Specify logging topic: "))
command += struct.pack("!B", tpc)
command += struct.pack('!B', tpc)
return command

View File

@@ -1,16 +0,0 @@
from config.object_ids import RW1_ID, RW2_ID, RW3_ID, RW4_ID
class SetIds:
TEMP_SET = 8
STATUS = 4
LAST_RESET = 2
TM_SET = 9
class Info:
pass
def pack_rw_cmds(op_code: str):
pass

View File

@@ -64,17 +64,17 @@ def pack_syrlinks_command(
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "3":
tc_queue.appendleft((QueueCommands.PRINT, "syrlinks: Set TX mode standby"))
command = object_id + struct.pack("!I", CommandIds.SET_TX_MODE_STANDBY)
command = object_id + struct.pack('!I', CommandIds.SET_TX_MODE_STANDBY)
command = PusTelecommand(service=8, subservice=128, ssc=10, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "4":
tc_queue.appendleft((QueueCommands.PRINT, "syrlinks: Set TX mode modulation"))
command = object_id + struct.pack("!I", CommandIds.SET_TX_MODE_MODULATION)
command = object_id + struct.pack('!I', CommandIds.SET_TX_MODE_MODULATION)
command = PusTelecommand(service=8, subservice=128, ssc=11, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "5":
tc_queue.appendleft((QueueCommands.PRINT, "syrlinks: Set TX mode CW"))
command = object_id + struct.pack("!I", CommandIds.SET_TX_MODE_CW)
command = object_id + struct.pack('!I', CommandIds.SET_TX_MODE_CW)
command = PusTelecommand(service=8, subservice=128, ssc=12, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "6":
@@ -89,26 +89,26 @@ def pack_syrlinks_command(
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "8":
tc_queue.appendleft((QueueCommands.PRINT, "Syrlinks: Read TX status"))
command = object_id + struct.pack("!I", CommandIds.READ_TX_STATUS)
command = object_id + struct.pack('!I', CommandIds.READ_TX_STATUS)
command = PusTelecommand(service=8, subservice=128, ssc=13, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "9":
tc_queue.appendleft((QueueCommands.PRINT, "Syrlinks: Read TX waveform"))
command = object_id + struct.pack("!I", CommandIds.READ_TX_WAVEFORM)
command = object_id + struct.pack('!I', CommandIds.READ_TX_WAVEFORM)
command = PusTelecommand(service=8, subservice=128, ssc=14, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "10":
tc_queue.appendleft(
(QueueCommands.PRINT, "Syrlinks: Read TX AGC value high byte")
)
command = object_id + struct.pack("!I", CommandIds.READ_TX_AGC_VALUE_HIGH_BYTE)
command = object_id + struct.pack('!I', CommandIds.READ_TX_AGC_VALUE_HIGH_BYTE)
command = PusTelecommand(service=8, subservice=128, ssc=15, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "11":
tc_queue.appendleft(
(QueueCommands.PRINT, "Syrlinks: Read TX AGC value low byte")
)
command = object_id + struct.pack("!I", CommandIds.READ_TX_AGC_VALUE_LOW_BYTE)
command = object_id + struct.pack('!I', CommandIds.READ_TX_AGC_VALUE_LOW_BYTE)
command = PusTelecommand(service=8, subservice=128, ssc=16, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "12":

View File

@@ -40,7 +40,6 @@ from pus_tc.system.time import pack_set_current_time_ascii_command
from pus_tc.system.acs import pack_acs_command, pack_sus_cmds
from pus_tc.devs.plpcdu import pack_pl_pcdu_commands
from pus_tc.devs.str_img_helper import pack_str_img_helper_command
from pus_tc.devs.rws import pack_rw_cmds
from pus_tc.system.tcs import pack_tcs_sys_commands
from config.definitions import CustomServiceList
from config.object_ids import (
@@ -234,13 +233,6 @@ def pack_service_queue_user(
return pack_tcs_sys_commands(tc_queue=service_queue, op_code=op_code)
if service == CustomServiceList.TIME.value:
return pack_set_current_time_ascii_command(tc_queue=service_queue, ssc=0)
if service in [
CustomServiceList.REACTION_WHEEL_1,
CustomServiceList.REACTION_WHEEL_2,
CustomServiceList.REACTION_WHEEL_3,
CustomServiceList.REACTION_WHEEL_4,
]:
return pack_rw_cmds(op_code=op_code)
LOGGER.warning("Invalid Service !")

View File

@@ -55,42 +55,40 @@ def handle_regular_hk_print(
hk_packet: Service3Base,
hk_data: bytes,
):
objb = object_id.as_bytes
object_id = object_id.as_bytes
set_id = hk_packet.set_id
"""This function is called when a Service 3 Housekeeping packet is received."""
if object_id in [obj_ids.RW1_ID, obj_ids.RW2_ID, obj_ids.RW3_ID, obj_ids.RW4_ID]:
handle_rw_hk_data(printer, object_id, set_id, hk_data)
if objb == obj_ids.SYRLINKS_HANDLER_ID:
if object_id == obj_ids.SYRLINKS_HANDLER_ID:
if set_id == SetIds.RX_REGISTERS_DATASET:
return handle_syrlinks_rx_registers_dataset(printer, hk_data)
elif set_id == SetIds.TX_REGISTERS_DATASET:
return handle_syrlinks_tx_registers_dataset(printer, hk_data)
else:
LOGGER.info("Service 3 TM: Syrlinks handler reply with unknown set id")
if objb == obj_ids.IMTQ_HANDLER_ID:
elif object_id == obj_ids.IMTQ_HANDLER_ID:
if (set_id >= ImtqSetIds.POSITIVE_X_TEST) and (
set_id <= ImtqSetIds.NEGATIVE_Z_TEST
):
return handle_self_test_data(printer, hk_data)
else:
LOGGER.info("Service 3 TM: Syrlinks handler reply with unknown set id")
if objb == obj_ids.GPS_HANDLER_0_ID or object_id == obj_ids.GPS_HANDLER_1_ID:
elif object_id == obj_ids.GPS_HANDLER_0_ID or object_id == obj_ids.GPS_HANDLER_1_ID:
handle_gps_data(printer=printer, hk_data=hk_data)
if objb == obj_ids.BPX_HANDLER_ID:
elif object_id == obj_ids.BPX_HANDLER_ID:
handle_bpx_hk_data(hk_data=hk_data, set_id=set_id, printer=printer)
if objb == obj_ids.CORE_CONTROLLER_ID:
elif object_id == obj_ids.CORE_CONTROLLER_ID:
return handle_core_hk_data(printer=printer, hk_data=hk_data)
if objb == obj_ids.PDU_1_HANDLER_ID:
elif object_id == obj_ids.PDU_1_HANDLER_ID:
return handle_pdu_data(
printer=printer, pdu_idx=1, set_id=set_id, hk_data=hk_data
)
if objb == obj_ids.PDU_2_HANDLER_ID:
elif object_id == obj_ids.PDU_2_HANDLER_ID:
return handle_pdu_data(
printer=printer, pdu_idx=2, set_id=set_id, hk_data=hk_data
)
if objb == obj_ids.P60_DOCK_HANDLER:
elif object_id == obj_ids.P60_DOCK_HANDLER:
handle_p60_hk_data(printer=printer, set_id=set_id, hk_data=hk_data)
if objb == obj_ids.PL_PCDU_ID:
elif object_id == obj_ids.PL_PCDU_ID:
log_to_both(printer, "Received PL PCDU HK data")
else:
LOGGER.info("Service 3 TM: Parsing for this SID has not been implemented.")
@@ -704,91 +702,6 @@ def handle_p60_hk_data(printer: FsfwTmTcPrinter, set_id: int, hk_data: bytes):
)
def handle_rw_hk_data(
printer: FsfwTmTcPrinter, object_id: ObjectId, set_id: int, hk_data: bytes
):
from pus_tc.devs.rws import SetIds
current_idx = 0
if set_id == SetIds.TEMP_SET:
log_to_both(
printer,
f"Received Temperature HK (ID {set_id}) from Reaction Wheel {object_id.name}",
)
temp = struct.unpack("!I", hk_data[0:4])
log_to_both(printer, f"Temperature {temp}")
current_idx += 4
if set_id == SetIds.STATUS:
log_to_both(
printer,
f"Received Status HK (ID {set_id}) from Reaction Wheel {object_id.name}",
)
fmt_str = "!iiBB"
inc_len = struct.calcsize(fmt_str)
(speed, ref_speed, state, clc_mode) = struct.unpack(
fmt_str, hk_data[current_idx : current_idx + inc_len]
)
current_idx += inc_len
log_to_both(
printer,
f"Speed {speed} rpm | Reference Speed {ref_speed} rpm | State {state} | CLC Mode {clc_mode}",
)
if set_id == SetIds.LAST_RESET:
log_to_both(
printer,
f"Received Last Reset HK (ID {set_id}) from Reaction Wheel {object_id.name}",
)
fmt_str = "!BB"
inc_len = struct.calcsize(fmt_str)
(last_reset_status, curr_reset_status) = struct.unpack(
fmt_str, hk_data[current_idx : current_idx + inc_len]
)
current_idx += inc_len
log_to_both(
printer,
f"Last Reset Status {last_reset_status} | Current Reset Status {curr_reset_status}",
)
if set_id == SetIds.TM_SET:
log_to_both(
printer,
f"Received TM HK (ID {set_id}) from Reaction Wheel {object_id.name}",
)
fmt_str = "!BiffBBiiIIIIIIIIIIIIIIII"
inc_len = struct.calcsize(fmt_str)
(
last_reset_status,
mcu_temp,
pressure_sens_temp,
pressure,
state,
clc_mode,
current_speed,
ref_speed,
num_invalid_crc_packets,
num_invalid_len_packets,
num_invalid_cmd_packets,
num_of_cmd_executed_requests,
num_of_cmd_replies,
uart_num_of_bytes_written,
uart_num_of_bytes_read,
uart_num_parity_errors,
uart_num_noise_errors,
uart_num_frame_errors,
uart_num_reg_overrun_errors,
uart_total_num_errors,
spi_num_bytes_written,
spi_num_bytes_read,
spi_num_reg_overrun_errors,
spi_total_num_errors,
) = struct.unpack(fmt_str, hk_data[current_idx : current_idx + inc_len])
pass
if current_idx > 0:
printer.print_validity_buffer(
validity_buffer=hk_data[current_idx:], num_vars=27
)
pass
def log_to_both(printer: FsfwTmTcPrinter, string: str):
print(string)
printer.file_logger.info(string)

Submodule tmtccmd updated: f4cc48127e...ea2992372f