Release v1.8.0 #16
@ -95,6 +95,28 @@ class EiveHookObject(TmTcHookBase):
|
|||||||
"10": ("PLOC Supervisor: Set time reference", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
"10": ("PLOC Supervisor: Set time reference", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
"11": ("PLOC Supervisor: Set boot timeout", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
"11": ("PLOC Supervisor: Set boot timeout", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
"12": ("PLOC Supervisor: Disable Hk", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
"12": ("PLOC Supervisor: Disable Hk", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"13": ("PLOC Supervisor: Request boot status report", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"14": ("PLOC Supervisor: Update available", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"15": ("PLOC Supervisor: Watchdogs enable", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"16": ("PLOC Supervisor: Watchdog Configure Timeout", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"17": ("PLOC Supervisor: Enable latchup alert", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"18": ("PLOC Supervisor: Disable latchup alert", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"19": ("PLOC Supervisor: Auto calibrate alert", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"20": ("PLOC Supervisor: Set alert limit", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"21": ("PLOC Supervisor: Set alert irq filter", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"22": ("PLOC Supervisor: Set ADC sweep period", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"23": ("PLOC Supervisor: Set ADC enabled channels", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"24": ("PLOC Supervisor: Set ADC window and stride", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"25": ("PLOC Supervisor: Set ADC threshold", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"26": ("PLOC Supervisor: Request latchup status report", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"27": ("PLOC Supervisor: Copy ADC data to MRAM", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"28": ("PLOC Supervisor: Enable/Disable NVM0/1/3", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"29": ("PLOC Supervisor: Select NVM", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"30": ("PLOC Supervisor: Run auto EM tests", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"31": ("PLOC Supervisor: MRAM Wipe", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"32": ("PLOC Supervisor: MRAM Dump", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"33": ("PLOC Supervisor: Print CPU stats", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
|
"34": ("PLOC Supervisor: Set debug verbosity", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||||
}
|
}
|
||||||
service_ploc_supv_tuple = ("PLOC Supervisor", op_code_dict_srv_ploc_supv)
|
service_ploc_supv_tuple = ("PLOC Supervisor", op_code_dict_srv_ploc_supv)
|
||||||
|
|
||||||
|
@ -13,6 +13,15 @@ from tmtccmd.config.definitions import QueueCommands
|
|||||||
from tmtccmd.tc.packer import TcQueueT
|
from tmtccmd.tc.packer import TcQueueT
|
||||||
from tmtccmd.ecss.tc import PusTelecommand
|
from tmtccmd.ecss.tc import PusTelecommand
|
||||||
|
|
||||||
|
latchup_id_dict = {
|
||||||
|
"0": "0.85V",
|
||||||
|
"1": "1.8V",
|
||||||
|
"2": "MISC",
|
||||||
|
"3": "3.3V",
|
||||||
|
"4": "NVM_4XO",
|
||||||
|
"5": "MISSION",
|
||||||
|
"6": "SAFECOTS"
|
||||||
|
}
|
||||||
|
|
||||||
class SupvActionIds:
|
class SupvActionIds:
|
||||||
HK_REPORT = 1
|
HK_REPORT = 1
|
||||||
@ -25,10 +34,40 @@ class SupvActionIds:
|
|||||||
RESET_MPSOC = 8
|
RESET_MPSOC = 8
|
||||||
SET_TIME_REF = 9
|
SET_TIME_REF = 9
|
||||||
DISABLE_HK = 10
|
DISABLE_HK = 10
|
||||||
|
GET_BOOT_STATUS_REPORT = 11
|
||||||
|
UPDATE_AVAILABLE = 12
|
||||||
|
WATCHDOGS_ENABLE = 13
|
||||||
|
WATCHDOGS_CONFIG_TIMEOUT = 14
|
||||||
|
ENABLE_LATCHUP_ALERT = 15
|
||||||
|
DISABLE_LATCHUP_ALERT = 16
|
||||||
|
AUTO_CALIBRATE_ALERT = 17
|
||||||
|
SET_ALERT_LIMIT = 18
|
||||||
|
SET_ALERT_IRQ_FILTER = 19
|
||||||
|
SET_ADC_SWEEP_PERIOD = 20
|
||||||
|
SET_ADC_ENABLED_CHANNELS = 21
|
||||||
|
SET_ADC_WINDOW_AND_STRIDE = 22
|
||||||
|
SET_ADC_THRESHOLD = 23
|
||||||
|
GET_LATCHUP_STATUS_REPORT = 24
|
||||||
|
COPY_ADC_DATA_TO_MRAM = 25
|
||||||
|
ENABLE_NVMS = 26
|
||||||
|
SELECT_NVM = 27
|
||||||
|
RUN_AUTO_EM_TESTS = 28
|
||||||
|
WIPE_MRAM = 29
|
||||||
|
DUMP_MRAM = 30
|
||||||
|
SET_DBG_VERBOSITY = 31
|
||||||
|
CAN_LOOPBACK_TEST = 32
|
||||||
|
PRINT_CPU_STATS = 33
|
||||||
|
SET_GPIO = 34
|
||||||
|
READ_GPIO = 35
|
||||||
|
RESTART_SUPERVISOR = 36
|
||||||
|
FACTORY_RESET = 37
|
||||||
|
REQUEST_LOGGING_DATA = 38
|
||||||
|
UPDATE_IMAGE_DATA = 39
|
||||||
|
|
||||||
|
|
||||||
class SupvHkIds:
|
class SupvHkIds:
|
||||||
HK_REPORT = 52
|
HK_REPORT = 52
|
||||||
|
BOOT_STATUS_REPORT = 53
|
||||||
|
|
||||||
|
|
||||||
def pack_ploc_supv_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code: str) -> TcQueueT:
|
def pack_ploc_supv_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code: str) -> TcQueueT:
|
||||||
@ -91,7 +130,117 @@ def pack_ploc_supv_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code:
|
|||||||
elif op_code == "12":
|
elif op_code == "12":
|
||||||
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Disable HK"))
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Disable HK"))
|
||||||
command = object_id + struct.pack('!I', SupvActionIds.DISABLE_HK)
|
command = object_id + struct.pack('!I', SupvActionIds.DISABLE_HK)
|
||||||
command = PusTelecommand(service=8, subservice=128, ssc=28, app_data=command)
|
command = PusTelecommand(service=8, subservice=128, ssc=29, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "13":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Request boot status report"))
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.GET_BOOT_STATUS_REPORT)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=30, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "14":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Update available"))
|
||||||
|
command = pack_update_available_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=31, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "15":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Watchdogs Enable"))
|
||||||
|
command = pack_watchdogs_enable_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=32, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "16":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Watchdog configure timeout"))
|
||||||
|
command = pack_watchdog_config_timeout_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=33, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "17":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Enable latchup alert"))
|
||||||
|
command = pack_lachtup_alert_cmd(object_id, True)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=34, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "18":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Disable latchup alert"))
|
||||||
|
command = pack_lachtup_alert_cmd(object_id, False)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=35, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "19":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Auto calibrate alert"))
|
||||||
|
command = pack_auto_calibrate_alert_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=36, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "20":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set alert limit"))
|
||||||
|
command = pack_set_alert_limit_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=37, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "21":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set alert irq filter"))
|
||||||
|
command = pack_set_alert_irq_filter_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=38, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "22":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set ADC sweep period"))
|
||||||
|
command = pack_set_adc_sweep_period_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=39, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "23":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set ADC enabled channels"))
|
||||||
|
command = pack_set_adc_enabled_channels_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=40, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "24":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set ADC window and stride"))
|
||||||
|
command = pack_set_adc_window_and_stride_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=41, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "25":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set ADC threshold"))
|
||||||
|
command = pack_set_adc_threshold_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=42, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "26":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Request latchup status report"))
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.GET_LATCHUP_STATUS_REPORT)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=43, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "27":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Copy ADC data to MRAM"))
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.COPY_ADC_DATA_TO_MRAM)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=44, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "28":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Enalbe/Disable NVMs"))
|
||||||
|
command = pack_enable_nvms_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=45, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "29":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Select NVM"))
|
||||||
|
command = pack_select_nvm_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=45, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "30":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Run auto EM tests"))
|
||||||
|
command = pack_auto_em_tests_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=45, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "31":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Wipe MRAM"))
|
||||||
|
command = pack_mram_wipe_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=46, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "32":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Dump MRAM"))
|
||||||
|
command = pack_mram_dump_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=47, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "33":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Print CPU stats"))
|
||||||
|
command = pack_print_cpu_stats_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=48, app_data=command)
|
||||||
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
elif op_code == "34":
|
||||||
|
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set debug verbosity"))
|
||||||
|
command = pack_set_debug_verbosity_cmd(object_id)
|
||||||
|
command = PusTelecommand(service=8, subservice=128, ssc=49, app_data=command)
|
||||||
tc_queue.appendleft(command.pack_command_tuple())
|
tc_queue.appendleft(command.pack_command_tuple())
|
||||||
|
|
||||||
return tc_queue
|
return tc_queue
|
||||||
@ -112,3 +261,244 @@ def pack_sel_boot_image_cmd(object_id: bytearray, mem: int, bp0: int, bp1: int,
|
|||||||
command = command + struct.pack('!B', bp1)
|
command = command + struct.pack('!B', bp1)
|
||||||
command = command + struct.pack('!B', bp2)
|
command = command + struct.pack('!B', bp2)
|
||||||
return command
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_update_available_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the udpate availabe command.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
"""
|
||||||
|
image_select = 1
|
||||||
|
image_partition = 0
|
||||||
|
image_size = 222
|
||||||
|
image_crc = 0x0
|
||||||
|
number_of_packets = 150
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.UPDATE_AVAILABLE)
|
||||||
|
command = command + struct.pack('!B', image_select)
|
||||||
|
command = command + struct.pack('!B', image_partition)
|
||||||
|
command = command + struct.pack('!I', image_size)
|
||||||
|
command = command + struct.pack('!I', image_crc)
|
||||||
|
command = command + struct.pack('!I', number_of_packets)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_watchdogs_enable_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the command to enable or disable watchdogs on the PLOC.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
@note Enable = 1, Disable = 0
|
||||||
|
"""
|
||||||
|
watchdog_ps = 1
|
||||||
|
watchdog_pl = 1
|
||||||
|
watchdog_int = 0
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.WATCHDOGS_ENABLE)
|
||||||
|
command = command + struct.pack('!B', watchdog_ps)
|
||||||
|
command = command + struct.pack('!B', watchdog_pl)
|
||||||
|
command = command + struct.pack('!B', watchdog_int)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_watchdog_config_timeout_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the command set the timeout of one of the three watchdogs of the PLOC.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
"""
|
||||||
|
watchdog = int(input("Specify watchdog (0 - PS, 1 - PL, 2 - INT):"))
|
||||||
|
timeout = int(input("Specify timeout (1000 ms - 360000 ms):"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.WATCHDOGS_CONFIG_TIMEOUT)
|
||||||
|
command = command + struct.pack('!B', watchdog)
|
||||||
|
command = command + struct.pack('!I', timeout)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_lachtup_alert_cmd(object_id: bytearray, state: bool) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the command to enable or disable a certain latchup alerts.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
@param state True - enable latchup alert, False - disable latchup alert
|
||||||
|
"""
|
||||||
|
latchup_id = get_latchup_id()
|
||||||
|
command = bytearray()
|
||||||
|
if state:
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.ENABLE_LATCHUP_ALERT)
|
||||||
|
else:
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.DISABLE_LATCHUP_ALERT)
|
||||||
|
command = command + struct.pack('!B', latchup_id)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_auto_calibrate_alert_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the command to auto calibrate a latchup alert.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
"""
|
||||||
|
latchup_id = get_latchup_id()
|
||||||
|
mg = int(input("Specify MG:"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.AUTO_CALIBRATE_ALERT)
|
||||||
|
command = command + struct.pack('!B', latchup_id)
|
||||||
|
command = command + struct.pack('!I', mg)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def get_latchup_id() -> int:
|
||||||
|
key_column_width = 10
|
||||||
|
description_column_width = 50
|
||||||
|
separator_width = key_column_width + description_column_width + 3
|
||||||
|
separator_string = separator_width * "-"
|
||||||
|
key_string = "Latchup ID".ljust(key_column_width)
|
||||||
|
description_string = "Description".ljust(description_column_width)
|
||||||
|
print(f"{key_string} | {description_string}")
|
||||||
|
print(separator_string)
|
||||||
|
for key in latchup_id_dict:
|
||||||
|
key_string = key.ljust(key_column_width)
|
||||||
|
description_string = latchup_id_dict[key].ljust(description_column_width)
|
||||||
|
print(f"{key_string} | {description_string}")
|
||||||
|
return int(input("Specify latchup ID:"))
|
||||||
|
|
||||||
|
|
||||||
|
def pack_set_alert_limit_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the command to set the limit of a latchup alert.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
"""
|
||||||
|
latchup_id = get_latchup_id()
|
||||||
|
dutycycle = int(input("Specify dutycycle:"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.AUTO_CALIBRATE_ALERT)
|
||||||
|
command = command + struct.pack('!B', latchup_id)
|
||||||
|
command = command + struct.pack('!I', dutycycle)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_set_alert_irq_filter_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the command to configure the latchup alert irq filter.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
"""
|
||||||
|
latchup_id = get_latchup_id()
|
||||||
|
tp = int(input("Specify TP:"))
|
||||||
|
div = int(input("Specify DIV:"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.SET_ALERT_IRQ_FILTER)
|
||||||
|
command = command + struct.pack('!B', latchup_id)
|
||||||
|
command = command + struct.pack('!B', tp)
|
||||||
|
command = command + struct.pack('!B', div)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_set_adc_sweep_period_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the command to set the limit of a latchup alert.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
"""
|
||||||
|
sweep_period = int(input("Specify sweep period (min 21 us):"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.SET_ADC_SWEEP_PERIOD)
|
||||||
|
command = command + struct.pack('!I', sweep_period)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_set_adc_enabled_channels_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
"""
|
||||||
|
@brief This function packs the command to enable or disable channels of the ADC.
|
||||||
|
@param object_id The object id of the PLOC supervisor handler.
|
||||||
|
"""
|
||||||
|
ch = int(input("Specify ch:"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.SET_ADC_ENABLED_CHANNELS)
|
||||||
|
command = command + struct.pack('!H', ch)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_set_adc_window_and_stride_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
window_size = int(input("Specify window size:"))
|
||||||
|
striding_step_size = int(input("Specify striding step size:"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.SET_ADC_WINDOW_AND_STRIDE)
|
||||||
|
command = command + struct.pack('!H', window_size)
|
||||||
|
command = command + struct.pack('!H', striding_step_size)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_set_adc_threshold_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
threshold = int(input("Specify threshold:"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.SET_ADC_THRESHOLD)
|
||||||
|
command = command + struct.pack('!I', threshold)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_enable_nvms_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
n01 = int(input("NVM0/1 (0 - off, 1 - on):"))
|
||||||
|
n3 = int(input("NVM3 (0 - off, 1 - on):"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.ENABLE_NVMS)
|
||||||
|
command = command + struct.pack('!B', n01)
|
||||||
|
command = command + struct.pack('!B', n3)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_select_nvm_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
mem = int(input("Specify NVM (0 - NVM0, 1 - MVM1):"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.SELECT_NVM)
|
||||||
|
command = command + struct.pack('!B', mem)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_auto_em_tests_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
test = int(input("Specify test (1 - complete, 2 - short):"))
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.RUN_AUTO_EM_TESTS)
|
||||||
|
command = command + struct.pack('!B', test)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_mram_wipe_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
start = int(input("Start address: 0x"), 16)
|
||||||
|
stop = int(input("Stop address: 0x"), 16)
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.WIPE_MRAM)
|
||||||
|
command = command + struct.pack('!I', start)
|
||||||
|
command = command + struct.pack('!I', stop)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_mram_dump_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
start = int(input("Start address: 0x"), 16)
|
||||||
|
stop = int(input("Stop address: 0x"), 16)
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.DUMP_MRAM)
|
||||||
|
command = command + struct.pack('!I', start)
|
||||||
|
command = command + struct.pack('!I', stop)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_print_cpu_stats_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
en = 1
|
||||||
|
command = bytearray()
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.PRINT_CPU_STATS)
|
||||||
|
command = command + struct.pack('!B', en)
|
||||||
|
return command
|
||||||
|
|
||||||
|
|
||||||
|
def pack_set_debug_verbosity_cmd(object_id: bytearray) -> bytearray:
|
||||||
|
command = bytearray()
|
||||||
|
print("Specify debug verbosity")
|
||||||
|
verbosity_options_dict = {
|
||||||
|
0: "None",
|
||||||
|
1: "Error",
|
||||||
|
2: "Warn",
|
||||||
|
3: "Info",
|
||||||
|
}
|
||||||
|
print("{:<6} | {}".format('Key', 'Description'))
|
||||||
|
for entry in verbosity_options_dict.items():
|
||||||
|
print("{:<6} | {}".format(entry[0], entry[1]))
|
||||||
|
verbosity = int(input("Specify verbosity key: "))
|
||||||
|
command = object_id + struct.pack('!I', SupvActionIds.SET_DBG_VERBOSITY)
|
||||||
|
command = command + struct.pack('!B', verbosity)
|
||||||
|
return command
|
@ -3,6 +3,7 @@ from typing import Tuple
|
|||||||
from config.object_ids import *
|
from config.object_ids import *
|
||||||
from pus_tc.imtq import ImtqActionIds
|
from pus_tc.imtq import ImtqActionIds
|
||||||
from pus_tc.ploc_mpsoc import PlocReplyIds
|
from pus_tc.ploc_mpsoc import PlocReplyIds
|
||||||
|
from pus_tc.ploc_supervisor import SupvActionIds
|
||||||
|
|
||||||
|
|
||||||
def user_analyze_service_8_data(
|
def user_analyze_service_8_data(
|
||||||
@ -32,6 +33,8 @@ def user_analyze_service_8_data(
|
|||||||
return handle_imtq_replies(action_id, custom_data)
|
return handle_imtq_replies(action_id, custom_data)
|
||||||
elif object_id == PLOC_MPSOC_ID:
|
elif object_id == PLOC_MPSOC_ID:
|
||||||
return handle_ploc_replies(action_id, custom_data)
|
return handle_ploc_replies(action_id, custom_data)
|
||||||
|
elif object_id == PLOC_SUPV_ID:
|
||||||
|
return handle_supervisor_replies(action_id, custom_data)
|
||||||
else:
|
else:
|
||||||
header_list = []
|
header_list = []
|
||||||
content_list = []
|
content_list = []
|
||||||
@ -56,3 +59,12 @@ def handle_ploc_replies(action_id: int, custom_data: bytearray) -> Tuple[list, l
|
|||||||
header_list = ['PLOC Memory Address', 'PLOC Mem Len', 'PLOC Read Memory Data']
|
header_list = ['PLOC Memory Address', 'PLOC Mem Len', 'PLOC Read Memory Data']
|
||||||
content_list = [custom_data[:4], custom_data[4:6], custom_data[6:10]]
|
content_list = [custom_data[:4], custom_data[4:6], custom_data[6:10]]
|
||||||
return header_list, content_list
|
return header_list, content_list
|
||||||
|
|
||||||
|
|
||||||
|
def handle_supervisor_replies(action_id: int, custom_data: bytearray) -> Tuple[list, list]:
|
||||||
|
header_list = []
|
||||||
|
content_list = []
|
||||||
|
if action_id == SupvActionIds.DUMP_MRAM:
|
||||||
|
header_list = ['MRAM Dump']
|
||||||
|
content_list = [custom_data[:len(custom_data)]]
|
||||||
|
return header_list, content_list
|
||||||
|
Loading…
Reference in New Issue
Block a user