1 |
Event ID (dec) |
Event ID (hex) |
Name |
Severity |
Description |
File Path |
123 |
11508 11604 |
0x2cf4 0x2d54 |
AUTONOMOUS_DEPLOYMENT_COMPLETED MPSOC_HANDLER_CRC_FAILURE |
INFO LOW |
No description PLOC reply has invalid crc |
mission/SolarArrayDeploymentHandler.h linux/payload/PlocMpsocHandler.h |
124 |
11601 11605 |
0x2d51 0x2d55 |
MEMORY_READ_RPT_CRC_FAILURE MPSOC_HANDLER_SEQUENCE_COUNT_MISMATCH |
LOW |
PLOC crc failure in telemetry packet Packet sequence count in received space packet does not match expected count P1: Expected sequence count P2: Received sequence count |
linux/payload/PlocMpsocHandler.h |
125 |
11602 11606 |
0x2d52 0x2d56 |
ACK_FAILURE MPSOC_SHUTDOWN_FAILED |
LOW HIGH |
PLOC receive acknowledgment failure report P1: Command Id which leads the acknowledgment failure report P2: The status field inserted by the MPSoC into the data field Supervisor fails to shutdown MPSoC. Requires to power off the PLOC and thus also to shutdown the supervisor. |
linux/payload/PlocMpsocHandler.h |
126 |
11607 |
0x2d57 |
SUPV_NOT_ON |
LOW |
SUPV not on for boot or shutdown process. P1: 0 for OFF transition, 1 for ON transition. |
linux/payload/PlocMpsocHandler.h |
127 |
11608 |
0x2d58 |
SUPV_REPLY_TIMEOUT |
LOW |
No description |
linux/payload/PlocMpsocHandler.h |
128 |
11603 11701 |
0x2d53 0x2db5 |
EXE_FAILURE SELF_TEST_I2C_FAILURE |
LOW |
PLOC receive execution failure report P1: Command Id which leads the execution failure report P2: The status field inserted by the MPSoC into the data field Get self test result returns I2C failure P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA |
linux/payload/PlocMpsocHandler.h mission/acs/ImtqHandler.h |
129 |
11604 11702 |
0x2d54 0x2db6 |
MPSOC_HANDLER_CRC_FAILURE SELF_TEST_SPI_FAILURE |
LOW |
PLOC reply has invalid crc Get self test result returns SPI failure. This concerns the MTM connectivity. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA |
linux/payload/PlocMpsocHandler.h mission/acs/ImtqHandler.h |
130 |
11605 11703 |
0x2d55 0x2db7 |
MPSOC_HANDLER_SEQUENCE_COUNT_MISMATCH SELF_TEST_ADC_FAILURE |
LOW |
Packet sequence count in received space packet does not match expected count P1: Expected sequence count P2: Received sequence count Get self test result returns failure in measurement of current and temperature. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA |
linux/payload/PlocMpsocHandler.h mission/acs/ImtqHandler.h |