HK Parsing and TC PROC Tests #76
@ -948,10 +948,12 @@ def add_ploc_supv_cmds(cmd_dict: ServiceOpCodeDictT):
|
|||||||
|
|
||||||
|
|
||||||
def add_proc_cmds(cmd_dict: ServiceOpCodeDictT):
|
def add_proc_cmds(cmd_dict: ServiceOpCodeDictT):
|
||||||
from pus_tc.system.proc import OpCodes, Info
|
from pus_tc.system.proc import OpCodes, KAI
|
||||||
|
|
||||||
op_code_dict = dict()
|
op_code_dict = dict()
|
||||||
add_op_code_entry(op_code_dict=op_code_dict, keys=OpCodes.HEATER, info=Info.HEATER)
|
add_op_code_entry(
|
||||||
|
op_code_dict=op_code_dict, keys=OpCodes.HEATER, info=KAI.HEATER[1]
|
||||||
|
)
|
||||||
add_service_op_code_entry(
|
add_service_op_code_entry(
|
||||||
srv_op_code_dict=cmd_dict,
|
srv_op_code_dict=cmd_dict,
|
||||||
name=CustomServiceList.PROCEDURE.value,
|
name=CustomServiceList.PROCEDURE.value,
|
||||||
@ -959,7 +961,15 @@ def add_proc_cmds(cmd_dict: ServiceOpCodeDictT):
|
|||||||
op_code_entry=op_code_dict,
|
op_code_entry=op_code_dict,
|
||||||
)
|
)
|
||||||
op_code_dict = dict()
|
op_code_dict = dict()
|
||||||
add_op_code_entry(op_code_dict=op_code_dict, keys=OpCodes.BAT_FT, info=Info.BAT_FT)
|
add_op_code_entry(
|
||||||
|
op_code_dict=op_code_dict, keys=OpCodes.BAT_FT, info=KAI.BAT_FT[1]
|
||||||
|
)
|
||||||
|
add_op_code_entry(
|
||||||
|
op_code_dict=op_code_dict, keys=OpCodes.PCDU_FT, info=KAI.PCDU_FT[1]
|
||||||
|
)
|
||||||
|
add_op_code_entry(
|
||||||
|
op_code_dict=op_code_dict, keys=OpCodes.CORE_FT, info=KAI.CORE_FT[1]
|
||||||
|
)
|
||||||
add_service_op_code_entry(
|
add_service_op_code_entry(
|
||||||
srv_op_code_dict=cmd_dict,
|
srv_op_code_dict=cmd_dict,
|
||||||
name=CustomServiceList.PROCEDURE.value,
|
name=CustomServiceList.PROCEDURE.value,
|
||||||
|
@ -7,55 +7,79 @@ from config.object_ids import (
|
|||||||
PDU_1_HANDLER_ID,
|
PDU_1_HANDLER_ID,
|
||||||
PDU_2_HANDLER_ID,
|
PDU_2_HANDLER_ID,
|
||||||
ACU_HANDLER_ID,
|
ACU_HANDLER_ID,
|
||||||
|
CORE_CONTROLLER_ID,
|
||||||
)
|
)
|
||||||
|
import config.object_ids as oids
|
||||||
from pus_tc.devs.bpx_batt import BpxSetIds
|
from pus_tc.devs.bpx_batt import BpxSetIds
|
||||||
|
from pus_tc.system.core import SetIds as CoreSetIds
|
||||||
from gomspace.gomspace_common import SetIds as GsSetIds
|
from gomspace.gomspace_common import SetIds as GsSetIds
|
||||||
|
|
||||||
|
|
||||||
class OpCodes:
|
class OpCodes:
|
||||||
HEATER = ["0", "heater"]
|
HEATER = ["0", "heater"]
|
||||||
BAT_FT = ["bat-ft"]
|
BAT_FT = ["bat-ft"]
|
||||||
|
CORE_FT = ["core-ft"]
|
||||||
PCDU_FT = ["pcdu-ft"]
|
PCDU_FT = ["pcdu-ft"]
|
||||||
|
|
||||||
|
|
||||||
class Info:
|
class KeyAndInfo:
|
||||||
HEATER = "heater procedure"
|
HEATER = ["Heater", "heater procedure"]
|
||||||
BAT_FT = "battery functional test"
|
BAT_FT = ["BPX Battery", "battery functional test"]
|
||||||
PCDU_FT = "pcdu functional test"
|
PCDU_FT = ["PCDU", "PCDU functional test"]
|
||||||
|
CORE_FT = ["OBC", "OBC functional test"]
|
||||||
|
|
||||||
|
|
||||||
|
KAI = KeyAndInfo
|
||||||
|
|
||||||
|
PROC_INFO_DICT = {
|
||||||
|
KAI.BAT_FT[0]: [OpCodes.BAT_FT, KAI.BAT_FT[1], 120.0, 10.0],
|
||||||
|
KAI.PCDU_FT[0]: [OpCodes.PCDU_FT, KeyAndInfo.PCDU_FT[1], 120.0, 10.0],
|
||||||
|
KAI.CORE_FT[0]: [OpCodes.CORE_FT, KeyAndInfo.CORE_FT[1], 120.0, 10.0],
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
|
def generic_print(tc_queue: TcQueueT, key: str):
|
||||||
|
info = PROC_INFO_DICT[key]
|
||||||
|
tc_queue.appendleft(
|
||||||
|
(QueueCommands.PRINT, f"Executing {info[0]} Procedure (OpCodes: {info[1]})")
|
||||||
|
)
|
||||||
|
|
||||||
|
|
||||||
|
def pack_generic_hk_listening_cmds(
|
||||||
|
tc_queue: TcQueueT, proc_key: str, sid: bytes, diag: bool
|
||||||
|
):
|
||||||
|
generic_print(tc_queue=tc_queue, key=proc_key)
|
||||||
|
listen_to_hk_for_x_seconds(
|
||||||
|
diag=diag,
|
||||||
|
tc_queue=tc_queue,
|
||||||
|
device=proc_key,
|
||||||
|
sid=sid,
|
||||||
|
interval_seconds=10.0,
|
||||||
|
collection_time=120.0,
|
||||||
|
)
|
||||||
|
|
||||||
|
|
||||||
def pack_proc_commands(tc_queue: TcQueueT, op_code: str):
|
def pack_proc_commands(tc_queue: TcQueueT, op_code: str):
|
||||||
if op_code in OpCodes.BAT_FT:
|
if op_code in OpCodes.BAT_FT:
|
||||||
device = Info.BAT_FT.split()[0]
|
key = KAI.BAT_FT[0]
|
||||||
tc_queue.appendleft(
|
|
||||||
(QueueCommands.PRINT, f"Executing {device} Procedure ({device})")
|
|
||||||
)
|
|
||||||
sid = make_sid(BPX_HANDLER_ID, BpxSetIds.GET_HK_SET)
|
sid = make_sid(BPX_HANDLER_ID, BpxSetIds.GET_HK_SET)
|
||||||
|
pack_generic_hk_listening_cmds(
|
||||||
listen_to_hk_for_x_seconds(
|
tc_queue=tc_queue, proc_key=key, sid=sid, diag=False
|
||||||
diag=False,
|
|
||||||
device=device,
|
|
||||||
sid=sid,
|
|
||||||
interval_seconds=10.0,
|
|
||||||
collection_time=120.0,
|
|
||||||
)
|
)
|
||||||
|
|
||||||
if op_code in OpCodes.PCDU_FT:
|
if op_code in OpCodes.PCDU_FT:
|
||||||
device = Info.PCDU_FT.split()[0]
|
key = KAI.PCDU_FT[0]
|
||||||
tc_queue.appendleft(
|
|
||||||
(QueueCommands.PRINT, f"Executing {device} Procedure ({device})")
|
|
||||||
)
|
|
||||||
sid = make_sid(P60_DOCK_HANDLER, GsSetIds.P60_CORE)
|
sid = make_sid(P60_DOCK_HANDLER, GsSetIds.P60_CORE)
|
||||||
|
pack_generic_hk_listening_cmds(
|
||||||
listen_to_hk_for_x_seconds(
|
tc_queue=tc_queue, proc_key=key, sid=sid, diag=False
|
||||||
diag=False,
|
|
||||||
device=device,
|
|
||||||
sid=sid,
|
|
||||||
interval_seconds=10.0,
|
|
||||||
collection_time=120.0,
|
|
||||||
)
|
)
|
||||||
|
|
||||||
pass
|
if op_code in OpCodes.CORE_FT:
|
||||||
|
key = KAI.CORE_FT[0]
|
||||||
|
sid = make_sid(oids.CORE_CONTROLLER_ID, CoreSetIds.HK)
|
||||||
|
pack_generic_hk_listening_cmds(
|
||||||
|
tc_queue=tc_queue, proc_key=key, sid=sid, diag=False
|
||||||
|
)
|
||||||
|
|
||||||
|
|
||||||
def listen_to_hk_for_x_seconds(
|
def listen_to_hk_for_x_seconds(
|
||||||
|
@ -26,7 +26,9 @@ def handle_mgm_lis3_hk_data(
|
|||||||
fmt_str, hk_data[0 : 0 + inc_len]
|
fmt_str, hk_data[0 : 0 + inc_len]
|
||||||
)
|
)
|
||||||
pw.dlog(f"Received MGM LIS3 from object {object_id}")
|
pw.dlog(f"Received MGM LIS3 from object {object_id}")
|
||||||
pw.dlog(f"Field strengths in micro Tesla X {field_x} | Y {field_y} | Z {field_z}")
|
pw.dlog(
|
||||||
|
f"Field strengths in micro Tesla X {field_x} | Y {field_y} | Z {field_z}"
|
||||||
|
)
|
||||||
pw.dlog(f"Temperature {temp} C")
|
pw.dlog(f"Temperature {temp} C")
|
||||||
|
|
||||||
|
|
||||||
@ -37,8 +39,8 @@ def handle_mgm_rm3100_hk_data(
|
|||||||
pw = PrintWrapper(printer)
|
pw = PrintWrapper(printer)
|
||||||
fmt_str = f"!fff"
|
fmt_str = f"!fff"
|
||||||
inc_len = struct.calcsize(fmt_str)
|
inc_len = struct.calcsize(fmt_str)
|
||||||
(field_x, field_y, field_z) = struct.unpack(
|
(field_x, field_y, field_z) = struct.unpack(fmt_str, hk_data[0 : 0 + inc_len])
|
||||||
fmt_str, hk_data[0 : 0 + inc_len]
|
|
||||||
)
|
|
||||||
pw.dlog(f"Received MGM LIS3 from object {object_id}")
|
pw.dlog(f"Received MGM LIS3 from object {object_id}")
|
||||||
pw.dlog(f"Field strengths in micro Tesla X {field_x} | Y {field_y} | Z {field_z}")
|
pw.dlog(
|
||||||
|
f"Field strengths in micro Tesla X {field_x} | Y {field_y} | Z {field_z}"
|
||||||
|
)
|
||||||
|
2
tmtccmd
2
tmtccmd
@ -1 +1 @@
|
|||||||
Subproject commit bca6440dba775b4691e693551e29849f2ab6542f
|
Subproject commit cf0afec762de4077f89b8da1f43b98e993fca6d0
|
Loading…
Reference in New Issue