Improvements for TVAC tests #98
@ -5,6 +5,8 @@
|
||||
@author J. Meier
|
||||
@date 25.03.2021
|
||||
"""
|
||||
import struct
|
||||
|
||||
from tmtccmd.config.definitions import QueueCommands
|
||||
|
||||
from tmtccmd.tc.packer import TcQueueT
|
||||
@ -276,11 +278,10 @@ def pack_dipole_command(
|
||||
command is sent.
|
||||
"""
|
||||
action_id = ImtqActionIds.start_actuation_dipole
|
||||
command = bytearray()
|
||||
command = object_id + action_id
|
||||
command.extend(x_dipole.to_bytes(length=2, byteorder="big"))
|
||||
command.extend(y_dipole.to_bytes(length=2, byteorder="big"))
|
||||
command.extend(z_dipole.to_bytes(length=2, byteorder="big"))
|
||||
command.extend(duration.to_bytes(length=2, byteorder="big"))
|
||||
command += struct.pack('!h', x_dipole)
|
||||
command += struct.pack('!h', y_dipole)
|
||||
command += struct.pack('!h', z_dipole)
|
||||
command += struct.pack('!h', duration)
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=22, app_data=command)
|
||||
return command
|
||||
|
@ -210,7 +210,7 @@ def pack_generic_hk_listening_cmds(
|
||||
)
|
||||
|
||||
if not cfg.use_tc_sched:
|
||||
tc_queue.appendleft((QueueCommands.WAIT, 120))
|
||||
tc_queue.appendleft((QueueCommands.WAIT, 60))
|
||||
sid_list.clear()
|
||||
diag_list.clear()
|
||||
|
||||
@ -332,7 +332,7 @@ def pack_proc_commands(tc_queue: TcQueueT, op_code: str):
|
||||
False,
|
||||
True,
|
||||
False,
|
||||
False
|
||||
True
|
||||
]
|
||||
pack_acs_command(tc_queue=tc_queue, op_code="acs-a")
|
||||
|
||||
@ -358,7 +358,7 @@ def pack_proc_commands(tc_queue: TcQueueT, op_code: str):
|
||||
False,
|
||||
True,
|
||||
False,
|
||||
False
|
||||
True
|
||||
]
|
||||
|
||||
for b_side_dev in b_side_pairs:
|
||||
@ -393,7 +393,7 @@ def pack_proc_commands(tc_queue: TcQueueT, op_code: str):
|
||||
False,
|
||||
True,
|
||||
False,
|
||||
False,
|
||||
True,
|
||||
]
|
||||
pack_generic_hk_listening_cmds(
|
||||
tc_queue=tc_queue,
|
||||
@ -413,12 +413,15 @@ def pack_proc_commands(tc_queue: TcQueueT, op_code: str):
|
||||
(oids.IMTQ_HANDLER_ID, ImtqSetIds.RAW_MTM_SET),
|
||||
]
|
||||
diag_list = [
|
||||
False,
|
||||
False,
|
||||
False,
|
||||
True,
|
||||
True,
|
||||
True,
|
||||
]
|
||||
|
||||
# mgt 1: imtq und hk
|
||||
# Command MGT to mode on
|
||||
pack_imtq_test_into(oids.IMTQ_HANDLER_ID, tc_queue=tc_queue, op_code="1")
|
||||
tc_queue.appendleft((QueueCommands.WAIT, 5))
|
||||
# Command MGT to normal mode
|
||||
pack_imtq_test_into(oids.IMTQ_HANDLER_ID, tc_queue=tc_queue, op_code="2")
|
||||
|
||||
for imtq_dev in imtq_pairs:
|
||||
@ -456,23 +459,24 @@ def pack_proc_commands(tc_queue: TcQueueT, op_code: str):
|
||||
diag_list = [
|
||||
False,
|
||||
False,
|
||||
True,
|
||||
False,
|
||||
True,
|
||||
False,
|
||||
False,
|
||||
Truehk,
|
||||
False,
|
||||
False,
|
||||
False,
|
||||
False,
|
||||
False,
|
||||
False,
|
||||
False,
|
||||
False,
|
||||
False,
|
||||
True,
|
||||
True,
|
||||
True,
|
||||
True,
|
||||
]
|
||||
pack_acs_command(tc_queue=tc_queue, op_code="acs-d")
|
||||
# mgt 2.: imtq + dual side + dipole
|
||||
pack_imtq_test_into(
|
||||
object_id=oids.IMTQ_HANDLER_ID, tc_queue=tc_queue, op_code="2"
|
||||
)
|
||||
# Command MGT to mode on
|
||||
pack_imtq_test_into(oids.IMTQ_HANDLER_ID, tc_queue=tc_queue, op_code="1")
|
||||
tc_queue.appendleft((QueueCommands.WAIT, 20))
|
||||
# Command MGT to normal mode
|
||||
pack_imtq_test_into(oids.IMTQ_HANDLER_ID, tc_queue=tc_queue, op_code="2")
|
||||
|
||||
for d_side_and_imtq_dev in d_side_and_imtq_pairs:
|
||||
oid = d_side_and_imtq_dev[0]
|
||||
|
@ -60,7 +60,7 @@ def handle_adis_gyro_hk(
|
||||
def handle_l3g_gyro_hk(
|
||||
object_id: ObjectId, printer: FsfwTmTcPrinter, set_id: int, hk_data: bytes
|
||||
):
|
||||
if set_id == L3gGyroSetIds:
|
||||
if set_id == L3gGyroSetIds.CORE_HK:
|
||||
pw = PrintWrapper(printer)
|
||||
fmt_str = "!ffff"
|
||||
inc_len = struct.calcsize(fmt_str)
|
||||
|
@ -10,8 +10,10 @@ import config.object_ids as obj_ids
|
||||
def handle_mgm_hk_data(
|
||||
object_id: ObjectId, printer: FsfwTmTcPrinter, set_id: int, hk_data: bytes
|
||||
):
|
||||
if object_id in [obj_ids.MGM_0_LIS3_HANDLER_ID, obj_ids.MGM_2_LIS3_HANDLER_ID]:
|
||||
if object_id.as_bytes in [obj_ids.MGM_0_LIS3_HANDLER_ID, obj_ids.MGM_2_LIS3_HANDLER_ID]:
|
||||
handle_mgm_lis3_hk_data(object_id, printer, set_id, hk_data)
|
||||
elif object_id.as_bytes in [obj_ids.MGM_1_RM3100_HANDLER_ID, obj_ids.MGM_3_RM3100_HANDLER_ID]:
|
||||
handle_mgm_rm3100_hk_data(object_id, printer, set_id, hk_data)
|
||||
pass
|
||||
|
||||
|
||||
@ -23,7 +25,7 @@ def handle_mgm_lis3_hk_data(
|
||||
fmt_str = "!ffff"
|
||||
inc_len = struct.calcsize(fmt_str)
|
||||
(field_x, field_y, field_z, temp) = struct.unpack(
|
||||
fmt_str, hk_data[0 : 0 + inc_len]
|
||||
fmt_str, hk_data[0: 0 + inc_len]
|
||||
)
|
||||
pw.dlog(f"Received MGM LIS3 from object {object_id}")
|
||||
pw.dlog(
|
||||
|
Loading…