112 lines
3.7 KiB
Python
112 lines
3.7 KiB
Python
from spacepackets.ecss import PusTelecommand
|
|
|
|
from eive_tmtc.config.definitions import CustomServiceList
|
|
from eive_tmtc.config.object_ids import BPX_HANDLER_ID
|
|
from tmtccmd.config.tmtc import (
|
|
tmtc_definitions_provider,
|
|
TmtcDefinitionWrapper,
|
|
OpCodeEntry,
|
|
)
|
|
from tmtccmd.tc import service_provider
|
|
from tmtccmd.tc.decorator import ServiceProviderParams
|
|
from tmtccmd.tc.pus_8_funccmd import make_fsfw_action_cmd
|
|
from tmtccmd.tc.pus_3_fsfw_hk import generate_one_hk_command, make_sid
|
|
from tmtccmd.tc.pus_200_fsfw_modes import pack_mode_data, Modes
|
|
from tmtccmd.tc.pus_200_fsfw_modes import Subservices as ModeSubservices
|
|
|
|
|
|
class BpxSetIds:
|
|
GET_HK_SET = 0
|
|
GET_CFG_SET = 5
|
|
|
|
|
|
class BpxActionIds:
|
|
REBOOT = 2
|
|
RESET_COUNTERS = 3
|
|
SET_CFG = 4
|
|
GET_CFG = 5
|
|
|
|
|
|
class BpxOpCodes:
|
|
HK = ["0", "hk"]
|
|
OFF = ["off"]
|
|
ON = ["on"]
|
|
RST_BOOT_CNT = ["1", "rst_boot_cnt"]
|
|
REQUEST_CFG = ["2", "cfg"]
|
|
REQUEST_CFG_HK = ["3", "cfg_hk"]
|
|
REBOOT = ["4", "reboot"]
|
|
|
|
|
|
@tmtc_definitions_provider
|
|
def add_bpx_cmd_definitions(defs: TmtcDefinitionWrapper):
|
|
oce = OpCodeEntry()
|
|
oce.add(keys=BpxOpCodes.ON, info="On command")
|
|
oce.add(keys=BpxOpCodes.OFF, info="Off command")
|
|
oce.add(keys=BpxOpCodes.HK, info="Request BPX HK")
|
|
oce.add(keys=BpxOpCodes.RST_BOOT_CNT, info="Reset Boot Count")
|
|
oce.add(keys=BpxOpCodes.REQUEST_CFG, info="Request Configuration Struct (Step 1)")
|
|
oce.add(
|
|
keys=BpxOpCodes.REQUEST_CFG_HK, info="Request Configuration Struct HK (Step 2)"
|
|
)
|
|
oce.add(keys=BpxOpCodes.REBOOT, info="Reboot Command")
|
|
defs.add_service(
|
|
name=CustomServiceList.BPX_BATTERY.value,
|
|
info="BPX Battery Handler",
|
|
op_code_entry=oce,
|
|
)
|
|
|
|
|
|
@service_provider(CustomServiceList.BPX_BATTERY.value)
|
|
def pack_bpx_commands(p: ServiceProviderParams):
|
|
op_code = p.op_code
|
|
q = p.queue_helper
|
|
if op_code in BpxOpCodes.HK:
|
|
q.add_log_cmd("Requesting BPX battery HK set")
|
|
sid = make_sid(object_id=BPX_HANDLER_ID, set_id=BpxSetIds.GET_HK_SET)
|
|
q.add_pus_tc(generate_one_hk_command(sid=sid))
|
|
if op_code in BpxOpCodes.OFF:
|
|
q.add_log_cmd("Off mode")
|
|
mode_cmd = pack_mode_data(BPX_HANDLER_ID, Modes.OFF, 0)
|
|
q.add_pus_tc(
|
|
PusTelecommand(
|
|
service=200,
|
|
subservice=ModeSubservices.TC_MODE_COMMAND,
|
|
app_data=mode_cmd,
|
|
)
|
|
)
|
|
if op_code in BpxOpCodes.ON:
|
|
q.add_log_cmd("On mode")
|
|
mode_cmd = pack_mode_data(BPX_HANDLER_ID, Modes.ON, 0)
|
|
q.add_pus_tc(
|
|
PusTelecommand(
|
|
service=200,
|
|
subservice=ModeSubservices.TC_MODE_COMMAND,
|
|
app_data=mode_cmd,
|
|
)
|
|
)
|
|
if op_code in BpxOpCodes.RST_BOOT_CNT:
|
|
q.add_log_cmd("Resetting reboot counters")
|
|
q.add_pus_tc(
|
|
make_fsfw_action_cmd(
|
|
object_id=BPX_HANDLER_ID, action_id=BpxActionIds.RESET_COUNTERS
|
|
)
|
|
)
|
|
if op_code in BpxOpCodes.REQUEST_CFG:
|
|
q.add_log_cmd("Requesting configuration struct")
|
|
q.add_pus_tc(
|
|
make_fsfw_action_cmd(
|
|
object_id=BPX_HANDLER_ID, action_id=BpxActionIds.GET_CFG
|
|
)
|
|
)
|
|
if op_code in BpxOpCodes.REQUEST_CFG_HK:
|
|
q.add_log_cmd("Requesting configuration struct HK")
|
|
sid = make_sid(object_id=BPX_HANDLER_ID, set_id=BpxSetIds.GET_CFG_SET)
|
|
q.add_pus_tc(generate_one_hk_command(sid=sid))
|
|
if op_code in BpxOpCodes.REBOOT:
|
|
q.add_log_cmd("Rebooting BPX battery")
|
|
q.add_pus_tc(
|
|
make_fsfw_action_cmd(
|
|
object_id=BPX_HANDLER_ID, action_id=BpxActionIds.REBOOT
|
|
)
|
|
)
|