eive-tmtc/eive_tmtc/tmtc/power/p60dock.py
Robin Mueller c4bd355146
All checks were successful
EIVE/-/pipeline/head This commit looks good
PLOC SUPV extensions
2023-11-08 18:18:40 +01:00

246 lines
9.1 KiB
Python

# -*- coding: utf-8 -*-
"""
@file tmtcc_tc_p60dock.py
@brief P60 Dock tests
@author J. Meier
@date 13.12.2020
"""
from eive_tmtc.tmtc.power.common_power import (
pack_common_gomspace_cmds,
req_hk_cmds,
pack_common_power_cmds,
SetId,
)
from tmtccmd.tc import DefaultPusQueueHelper
from eive_tmtc.gomspace.gomspace_common import (
TableEntry,
Channel,
TableIds,
pack_get_param_command,
pack_gnd_wdt_reset_command,
pack_ping_command,
pack_reboot_command,
pack_set_u8_param_command,
pack_set_u16_param_command,
)
from eive_tmtc.config.object_ids import P60_DOCK_HANDLER
from tmtccmd.util import ObjectIdU32
class P60OpCode:
STACK_3V3_ON = "stack_3v3_on"
STACK_3V3_OFF = "stack_3v3_off"
STACK_5V_ON = "stack_5v_on"
STACK_5V_OFF = "stack_5v_off"
ACU_OFF = "acu_off"
ACU_ON = "acu_on"
TEST = ["test", "0"]
class P60Info:
PREFIX = "P60 Dock"
STACK_3V3_ON = f"{PREFIX}: Turn Stack 3V3 on"
STACK_3V3_OFF = f"{PREFIX}: Turn Stack 3V3 off"
STACK_5V_ON = f"{PREFIX}: Turn Stack 5V on"
STACK_5V_OFF = f"{PREFIX}: Turn Stack 5V off"
class P60DockTestProcedure:
"""
@brief Use this class to define the tests to perform for the P60Dock.
@details Setting all to True will run all tests.
Setting all to False will only run the tests set to True.
"""
all = False
reboot = False
read_gnd_wdt = False
gnd_wdt_reset = False
ping = False
channel_3_off = False # pdu2
read_temperature1 = False
read_channel_3_state = False # pdu2
read_cur_lu_lim_0 = False
channel_3_on = False # pdu2
invalid_table_id_test = (
False # Test to check if software properly handles invalid table ids
)
invalid_address_test = (
False # Test to check if software properly handles invalid addresses
)
invalid_parameter_size_test = False
class P60DockConfigTable:
out_en_0 = TableEntry(bytearray([0x00, 0x68]), TableEntry.uint8_size) # ACU VCC
out_en_1 = TableEntry(bytearray([0x00, 0x69]), TableEntry.uint8_size) # PDU1 VCC
out_en_2 = TableEntry(bytearray([0x00, 0x6A]), TableEntry.uint8_size) # unused
out_en_3 = TableEntry(bytearray([0x00, 0x6B]), TableEntry.uint8_size) # PDU2 VCC
out_en_4 = TableEntry(bytearray([0x00, 0x6C]), TableEntry.uint8_size) # ACU VBAT
out_en_5 = TableEntry(bytearray([0x00, 0x6D]), TableEntry.uint8_size) # unused
out_en_6 = TableEntry(bytearray([0x00, 0x6E]), TableEntry.uint8_size) # PDU1 VBAT
out_en_7 = TableEntry(bytearray([0x00, 0x6F]), TableEntry.uint8_size) # PDU2 VBAT
out_en_8 = TableEntry(bytearray([0x00, 0x70]), TableEntry.uint8_size) # Stack VBAT
out_en_9 = TableEntry(bytearray([0x00, 0x71]), TableEntry.uint8_size) # Stack 3V3
out_en_10 = TableEntry(bytearray([0x00, 0x72]), TableEntry.uint8_size) # Stack 5V
out_en_11 = TableEntry(
bytearray([0x00, 0x73]), TableEntry.uint8_size
) # GS 3V3 (unused)
out_en_12 = TableEntry(
bytearray([0x00, 0x74]), TableEntry.uint8_size
) # GS 5V (unused)
# When channel consumes more than cur_lu_lim, channel is turned of immediately
cur_lu_lim_0 = TableEntry(bytearray([0x00, 0xF8]), TableEntry.uint16_size)
class P60DockHkTable:
temperature1 = TableEntry(bytearray([0x00, 0x44]), TableEntry.uint16_size)
temperature2 = TableEntry(bytearray([0x00, 0x46]), TableEntry.uint16_size)
# Ground WDT value (remaining seconds until reboot)
wdt_gnd_left = TableEntry(bytearray([0x00, 0xA8]), TableEntry.uint32_size)
def pack_p60dock_cmds( # noqa C901: Complexity okay here.
object_id: ObjectIdU32, q: DefaultPusQueueHelper, op_code: str
):
objb = object_id.as_bytes
pack_common_power_cmds("P60 Dock", object_id, q, op_code)
pack_common_gomspace_cmds("P60 Dock", object_id, q, op_code)
p60_dock_req_hk_cmds(q, op_code)
if op_code in P60OpCode.STACK_3V3_ON:
q.add_log_cmd(P60Info.STACK_3V3_ON)
q.add_pus_tc(
pack_set_u8_param_command(
objb,
P60DockConfigTable.out_en_9.parameter_address,
Channel.on,
)
)
if op_code in P60OpCode.STACK_3V3_OFF:
q.add_log_cmd(P60Info.STACK_3V3_OFF)
q.add_pus_tc(
pack_set_u8_param_command(
objb,
P60DockConfigTable.out_en_9.parameter_address,
Channel.off,
)
)
if op_code in P60OpCode.STACK_5V_ON:
q.add_log_cmd(P60Info.STACK_5V_ON)
q.add_pus_tc(
pack_set_u8_param_command(
objb,
P60DockConfigTable.out_en_10.parameter_address,
Channel.on,
)
)
if op_code in P60OpCode.STACK_5V_OFF:
q.add_log_cmd(P60Info.STACK_5V_OFF)
q.add_pus_tc(
pack_set_u8_param_command(
objb,
P60DockConfigTable.out_en_10.parameter_address,
Channel.off,
)
)
if P60DockTestProcedure.all or P60DockTestProcedure.reboot:
q.add_log_cmd("P60 Dock: Reboot")
q.add_pus_tc(pack_reboot_command(object_id))
if P60DockTestProcedure.all or P60DockTestProcedure.read_gnd_wdt:
q.add_log_cmd("P60 Dock: Reading ground watchdog timer value")
q.add_pus_tc(
pack_get_param_command(
objb,
TableIds.HK,
P60DockHkTable.wdt_gnd_left.parameter_address,
P60DockHkTable.wdt_gnd_left.parameter_size,
)
)
if P60DockTestProcedure.all or P60DockTestProcedure.gnd_wdt_reset:
q.add_log_cmd("P60 Dock: Testing ground watchdog reset")
q.add_pus_tc(pack_gnd_wdt_reset_command(object_id))
if P60DockTestProcedure.all or P60DockTestProcedure.ping:
q.add_log_cmd("P60 Dock: Ping")
ping_data = bytearray([0, 1, 2, 3, 4, 5, 6, 7, 8, 9])
q.add_pus_tc(pack_ping_command(object_id, ping_data))
if P60DockTestProcedure.all or P60DockTestProcedure.channel_3_off:
q.add_log_cmd("P60 Dock: Testing setting output channel 3 off")
parameter = 0 # set channel off
q.add_pus_tc(
pack_set_u8_param_command(
objb,
P60DockConfigTable.out_en_3.parameter_address,
parameter,
)
)
if P60DockTestProcedure.all or P60DockTestProcedure.read_temperature1:
q.add_log_cmd("P60 Dock: Testing temperature reading")
q.add_pus_tc(
pack_get_param_command(
objb,
TableIds.HK,
P60DockHkTable.temperature1.parameter_address,
P60DockHkTable.temperature1.parameter_size,
)
)
if P60DockTestProcedure.all or P60DockTestProcedure.channel_3_on:
q.add_log_cmd("P60 Dock: Testing Output Channel 3 state (PDU2)")
q.add_pus_tc(
pack_get_param_command(
objb,
TableIds.CONFIG,
P60DockConfigTable.out_en_3.parameter_address,
P60DockConfigTable.out_en_3.parameter_size,
)
)
if P60DockTestProcedure.all or P60DockTestProcedure.read_cur_lu_lim_0:
q.add_log_cmd("P60 Dock: Reading current limit value of output channel 0")
q.add_pus_tc(
pack_get_param_command(
objb,
TableIds.CONFIG,
P60DockConfigTable.cur_lu_lim_0.parameter_address,
P60DockConfigTable.cur_lu_lim_0.parameter_size,
)
)
if P60DockTestProcedure.all or P60DockTestProcedure.channel_3_on:
q.add_log_cmd("P60 Dock: Testing setting output channel 3 on")
parameter = 1 # set channel on
q.add_pus_tc(
pack_set_u8_param_command(
objb,
P60DockConfigTable.out_en_3.parameter_address,
parameter,
)
)
if P60DockTestProcedure.all or P60DockTestProcedure.invalid_table_id_test:
q.add_log_cmd("P60 Dock: Testing invalid table id handling")
table_id_invalid = 5
q.add_pus_tc(
pack_get_param_command(
objb,
table_id_invalid,
P60DockHkTable.temperature1.parameter_address,
P60DockHkTable.temperature1.parameter_size,
)
)
if P60DockTestProcedure.all or P60DockTestProcedure.invalid_address_test:
q.add_log_cmd("P60 Dock: Testing invalid address handling in get param command")
invalid_address = bytearray([0x01, 0xF4])
q.add_pus_tc(
pack_get_param_command(
objb,
TableIds.HK,
invalid_address,
P60DockHkTable.temperature1.parameter_size,
)
)
q.add_log_cmd("P60 Dock: Testing invalid address handling in set param command")
invalid_address = bytearray([0x01, 0xF4])
parameter = 1
q.add_pus_tc(pack_set_u16_param_command(objb, invalid_address, parameter))
def p60_dock_req_hk_cmds(q: DefaultPusQueueHelper, op_code: str):
req_hk_cmds("P60 Dock", q, op_code, P60_DOCK_HANDLER, [SetId.CORE, SetId.AUX])