eive-tmtc/pus_tc/p60dock.py
2021-07-24 14:58:47 +02:00

162 lines
8.7 KiB
Python

# -*- coding: utf-8 -*-
"""
@file tmtcc_tc_p60dock.py
@brief P60 Dock tests
@author J. Meier
@date 13.12.2020
"""
from tmtccmd.config.definitions import QueueCommands
from tmtccmd.tc.packer import TcQueueT
from tmtccmd.ecss.tc import PusTelecommand
from gomspace.gomspace_common import *
class P60DockTestProcedure:
"""
@brief Use this class to define the tests to perform for the P60Dock.
@details Setting all to True will run all tests.
Setting all to False will only run the tests set to True.
"""
all = False
reboot = False
read_gnd_wdt = False
gnd_wdt_reset = False
ping = False
channel_3_off = False # pdu2
read_temperature1 = True
read_channel_3_state = False # pdu2
read_cur_lu_lim_0 = False
channel_3_on = False # pdu2
invalid_table_id_test = False # Test to check if software properly handles invalid table ids
invalid_address_test = False # Test to check if software properly handles invalid addresses
invalid_parameter_size_test = False
class P60DockConfigTable:
out_en_0 = TableEntry(bytearray([0x00, 0x68]), TableEntry.uint8_size) # ACU
out_en_1 = TableEntry(bytearray([0x00, 0x69]), TableEntry.uint8_size) # PDU1
out_en_2 = TableEntry(bytearray([0x00, 0x6A]), TableEntry.uint8_size)
out_en_3 = TableEntry(bytearray([0x00, 0x6B]), TableEntry.uint8_size) # PDU2
# When channel consumes more than cur_lu_lim, channel is turned of immediately
cur_lu_lim_0 = TableEntry(bytearray([0x00, 0xF8]), TableEntry.uint16_size)
class P60DockHkTable:
temperature1 = TableEntry(bytearray([0x00, 0x44]), TableEntry.uint16_size)
temperature2 = TableEntry(bytearray([0x00, 0x46]), TableEntry.uint16_size)
# Ground WDT value (remaining seconds until reboot)
wdt_gnd_left = TableEntry(bytearray([0x00, 0xA8]), TableEntry.uint32_size)
def pack_p60dock_test_into(object_id: bytearray, tc_queue: TcQueueT) -> TcQueueT:
if P60DockTestProcedure.all or P60DockTestProcedure.reboot:
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Reboot"))
command = pack_reboot_command(object_id)
command = PusTelecommand(service=8, subservice=128, ssc=22, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.read_gnd_wdt:
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Reading ground watchdog timer value"))
command = pack_get_param_command(
object_id, TableIds.hk, P60DockHkTable.wdt_gnd_left.parameter_address,
P60DockHkTable.wdt_gnd_left.parameter_size
)
command = PusTelecommand(service=8, subservice=128, ssc=20, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.gnd_wdt_reset:
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Testing ground watchdog reset"))
command = pack_gnd_wdt_reset_command(object_id)
command = PusTelecommand(service=8, subservice=128, ssc=21, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.ping:
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Ping"))
ping_data = bytearray([0, 1, 2, 3, 4, 5, 6, 7, 8, 9])
command = pack_ping_command(object_id, ping_data)
command = PusTelecommand(service=8, subservice=128, ssc=22, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.channel_3_off:
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Testing setting output channel 3 off"))
parameter = 0 # set channel off
command = pack_set_param_command(object_id, P60DockConfigTable.out_en_3.parameter_address,
P60DockConfigTable.out_en_3.parameter_size, parameter)
command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.read_temperature1:
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Testing temperature reading"))
command = pack_get_param_command(
object_id, TableIds.hk, P60DockHkTable.temperature1.parameter_address,
P60DockHkTable.temperature1.parameter_size
)
command = PusTelecommand(service=8, subservice=128, ssc=24, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.channel_3_on:
tc_queue.appendleft((QueueCommands.PRINT,
"P60 Dock: Testing Output Channel 3 state (PDU2)"))
command = pack_get_param_command(object_id, TableIds.config, P60DockConfigTable.out_en_3.parameter_address,
P60DockConfigTable.out_en_3.parameter_size)
command = PusTelecommand(service=8, subservice=128, ssc=25, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.read_cur_lu_lim_0:
tc_queue.appendleft((QueueCommands.PRINT,
"P60 Dock: Reading current limit value of output channel 0"))
command = pack_get_param_command(
object_id, TableIds.config, P60DockConfigTable.cur_lu_lim_0.parameter_address,
P60DockConfigTable.cur_lu_lim_0.parameter_size
)
command = PusTelecommand(service=8, subservice=128, ssc=26, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.channel_3_on:
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Testing setting output channel 3 on"))
parameter = 1 # set channel on
command = pack_set_param_command(object_id, P60DockConfigTable.out_en_3.parameter_address,
P60DockConfigTable.out_en_3.parameter_size, parameter)
command = PusTelecommand(service=8, subservice=128, ssc=27, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.invalid_table_id_test:
tc_queue.appendleft((QueueCommands.PRINT, "P60 Dock: Testing invalid table id handling"))
table_id_invalid = 5
command = pack_get_param_command(
object_id, table_id_invalid, P60DockHkTable.temperature1.parameter_address,
P60DockHkTable.temperature1.parameter_size
)
command = PusTelecommand(service=8, subservice=128, ssc=28, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.invalid_address_test:
tc_queue.appendleft((QueueCommands.PRINT,
"P60 Dock: Testing invalid address handling in get param command"))
invalid_address = bytearray([0x01, 0xF4])
command = pack_get_param_command(object_id, TableIds.hk, invalid_address,
P60DockHkTable.temperature1.parameter_size)
command = PusTelecommand(service=8, subservice=128, ssc=29, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
tc_queue.appendleft((QueueCommands.PRINT,
"P60 Dock: Testing invalid address handling in set param command"))
invalid_address = bytearray([0x01, 0xF4])
parameter_size = 2
parameter = 1
command = pack_set_param_command(object_id, invalid_address, parameter_size, parameter)
command = PusTelecommand(service=8, subservice=128, ssc=30, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if P60DockTestProcedure.all or P60DockTestProcedure.invalid_parameter_size_test:
tc_queue.appendleft(
(QueueCommands.PRINT,
"P60 Dock: Testing handling of invalid parameter sizes in get-param command")
)
invalid_size = 5
command = pack_get_param_command(
object_id, TableIds.hk, P60DockHkTable.temperature1.parameter_address, invalid_size
)
command = PusTelecommand(service=8, subservice=128, ssc=31, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
tc_queue.appendleft(
(QueueCommands.PRINT,
"P60 Dock: Testing handling of invalid parameter size in set-param command")
)
parameter = 1
command = pack_set_param_command(
object_id, P60DockConfigTable.out_en_3.parameter_address, invalid_size, parameter
)
command = PusTelecommand(service=8, subservice=128, ssc=32, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
return tc_queue