eive-tmtc/pus_tc/tmp1075.py
2021-07-24 14:58:47 +02:00

64 lines
2.5 KiB
Python

# -*- coding: utf-8 -*-
"""
@file tmp1075.py
@brief TMP1075 tests
@author J. Meier
@date 06.01.2021
"""
from tmtccmd.config.definitions import QueueCommands
from tmtccmd.tc.packer import TcQueueT
from tmtccmd.ecss.tc import PusTelecommand
from pus_tc.service_200_mode import pack_mode_data
class Tmp1075TestProcedure:
"""
@brief Use this class to define the tests to perform for the Tmp1075.
@details Setting all to True will run all tests.
Setting all to False will only run the tests set to True.
"""
all = False
start_adc_conversion = False
get_temp = False
set_mode_normal = True # Setting mode to normal starts continuous temperature reading
set_mode_on = False # If mode is MODE_ON, temperature will only be read on command
class Tmp1075ActionIds:
get_temp = bytearray([0x0, 0x0, 0x0, 0x01])
start_adc_conversion = bytearray([0x0, 0x0, 0x0, 0x02])
def pack_tmp1075_test_into(object_id: bytearray, op_code: str, tc_queue: TcQueueT) -> TcQueueT:
tc_queue.appendleft(
(QueueCommands.PRINT,
"Testing Tmp1075 Temperature Sensor Handler with object id: 0x" + object_id.hex())
)
if Tmp1075TestProcedure.all or Tmp1075TestProcedure.start_adc_conversion:
tc_queue.appendleft((QueueCommands.PRINT, "TMP1075: Starting new temperature conversion"))
command = object_id + Tmp1075ActionIds.start_adc_conversion
command = PusTelecommand(service=8, subservice=128, ssc=23, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if Tmp1075TestProcedure.all or Tmp1075TestProcedure.get_temp:
tc_queue.appendleft((QueueCommands.PRINT, "TMP1075: Read temperature"))
command = object_id + Tmp1075ActionIds.get_temp
command = PusTelecommand(service=8, subservice=128, ssc=24, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if Tmp1075TestProcedure.set_mode_normal:
tc_queue.appendleft((QueueCommands.PRINT, "TMP1075: Set Mode Normal"))
mode_data = pack_mode_data(object_id, 2, 0)
command = PusTelecommand(service=200, subservice=1, ssc=220, app_data=mode_data)
tc_queue.appendleft(command.pack_command_tuple())
if Tmp1075TestProcedure.set_mode_on:
tc_queue.appendleft((QueueCommands.PRINT, "TMP1075: Set Mode On"))
mode_data = pack_mode_data(object_id, 1, 0)
command = PusTelecommand(service=200, subservice=1, ssc=221, app_data=mode_data)
tc_queue.appendleft(command.pack_command_tuple())
return tc_queue