240 lines
7.2 KiB
Python
240 lines
7.2 KiB
Python
import enum
|
|
from typing import Optional
|
|
|
|
from tmtccmd.config import QueueCommands
|
|
from tmtccmd.tc.definitions import TcQueueT
|
|
from tmtccmd.tc.service_200_mode import pack_mode_data, Modes, Subservices
|
|
from tmtccmd.tc.service_20_parameter import (
|
|
pack_scalar_double_param_app_data,
|
|
pack_fsfw_load_param_cmd,
|
|
pack_boolean_parameter_app_data,
|
|
)
|
|
from tmtccmd.utility.logger import get_console_logger
|
|
from spacepackets.ecss.tc import PusTelecommand
|
|
from config.object_ids import PL_PCDU_ID
|
|
|
|
LOGGER = get_console_logger()
|
|
|
|
|
|
class OpCodes:
|
|
SWITCH_ON = ["0", "on"]
|
|
SWITCH_OFF = ["1", "off"]
|
|
NORMAL_SSR = ["2", "nml-ssr"]
|
|
NORMAL_DRO = ["3", "nml-dro"]
|
|
NORMAL_X8 = ["4", "nml-x8"]
|
|
NORMAL_TX = ["5", "nml-tx"]
|
|
NORMAL_MPA = ["6", "nml-mpa"]
|
|
NORMAL_HPA = ["7", "nml-hpa"]
|
|
|
|
INJECT_SSR_TO_DRO_FAILURE = ["10", "inject-ssr-dro-fault"]
|
|
INJECT_DRO_TO_X8_FAILURE = ["11", "inject-dro-x8-fault"]
|
|
INJECT_X8_TO_TX_FAILURE = ["12", "inject-x8-tx-fault"]
|
|
INJECT_TX_TO_MPA_FAILURE = ["13", "inject-tx-mpa-fault"]
|
|
INJECT_MPA_TO_HPA_FAILURE = ["14", "inject-mpa-hpa-fault"]
|
|
INJECT_ALL_ON_FAILURE = ["15", "inject-all-on-fault"]
|
|
|
|
# The following commands might become deprecated in the future
|
|
UPDATE_DRO_TO_X8_WAIT = ["128", "dro-to-x8-wait"]
|
|
UPDATE_X8_TO_TX_WAIT_TIME = ["129", "x8-to-tx-wait"]
|
|
UPDATE_TX_TO_MPA_WAIT_TIME = ["130", "tx-to-mpa-wait"]
|
|
UPDATE_MPA_TO_HPA_WAIT_TIME = ["131", "mpa-to-hpa-wait"]
|
|
|
|
|
|
class Info:
|
|
NORMAL = "PL PCDU ADC modules normal"
|
|
SWITCH_ON = "Switching PL PCDU on"
|
|
SWITCH_OFF = "Switching PL PCDU off"
|
|
NORMAL_SSR = f"{NORMAL}, SSR on"
|
|
NORMAL_DRO = f"{NORMAL},DRO on"
|
|
NORMAL_X8 = f"{NORMAL}, X8 on"
|
|
NORMAL_TX = f"{NORMAL}, TX on"
|
|
NORMAL_MPA = f"{NORMAL}, MPA on"
|
|
NORMAL_HPA = f"{NORMAL}, HPA on"
|
|
|
|
|
|
class NormalSubmodes(enum.IntEnum):
|
|
ALL_OFF = 0
|
|
SOLID_STATE_RELAYS_ADC_ON = 1
|
|
DRO_ON = 2
|
|
X8_ON = 3
|
|
TX_ON = 4
|
|
MPA_ON = 5
|
|
HPA_ON = 6
|
|
|
|
|
|
class ParamIds(enum.IntEnum):
|
|
NEG_V_LOWER_BOUND = 0
|
|
NEG_V_UPPER_BOUND = 1
|
|
|
|
DRO_U_LOWER_BOUND = 2
|
|
DRO_U_UPPER_BOUND = 3
|
|
DRO_I_UPPER_BOUND = 4
|
|
|
|
X8_U_LOWER_BOUND = 5
|
|
X8_U_UPPER_BOUND = 6
|
|
X8_I_UPPER_BOUND = 7
|
|
|
|
TX_U_LOWER_BOUND = 8
|
|
TX_U_UPPER_BOUND = 9
|
|
TX_I_UPPER_BOUND = 10
|
|
|
|
MPA_U_LOWER_BOUND = 11
|
|
MPA_U_UPPER_BOUND = 12
|
|
MPA_I_UPPER_BOUND = 13
|
|
|
|
HPA_U_LOWER_BOUND = 14
|
|
HPA_U_UPPER_BOUND = 15
|
|
HPA_I_UPPER_BOUND = 16
|
|
|
|
SSR_TO_DRO_WAIT_TIME = 17
|
|
DRO_TO_X8_WAIT_TIME = 18
|
|
X8_TO_TX_WAIT_TIME = 19
|
|
TX_TO_MPA_WAIT_TIME = 20
|
|
MPA_TO_HPA_WAIT_TIME = 21
|
|
|
|
INJECT_SSR_TO_DRO_FAILURE = 30
|
|
INJECT_DRO_TO_X8_FAILURE = 31
|
|
INJECT_X8_TO_TX_FAILURE = 32
|
|
INJECT_TX_TO_MPA_FAILURE = 33
|
|
INJECT_MPA_TO_HPA_FAILURE = 34
|
|
INJECT_ALL_ON_FAILURE = 35
|
|
|
|
|
|
def pack_pl_pcdu_commands(tc_queue: TcQueueT, op_code: str):
|
|
if op_code in OpCodes.SWITCH_ON:
|
|
pack_pl_pcdu_mode_cmd(
|
|
tc_queue=tc_queue, info=Info.SWITCH_ON, mode=Modes.ON, submode=0
|
|
)
|
|
if op_code in OpCodes.SWITCH_OFF:
|
|
pack_pl_pcdu_mode_cmd(
|
|
tc_queue=tc_queue, info=Info.SWITCH_OFF, mode=Modes.OFF, submode=0
|
|
)
|
|
if op_code in OpCodes.NORMAL_SSR:
|
|
pack_pl_pcdu_mode_cmd(
|
|
tc_queue=tc_queue,
|
|
info=Info.NORMAL_SSR,
|
|
mode=Modes.NORMAL,
|
|
submode=NormalSubmodes.SOLID_STATE_RELAYS_ADC_ON,
|
|
)
|
|
if op_code in OpCodes.NORMAL_DRO:
|
|
pack_pl_pcdu_mode_cmd(
|
|
tc_queue=tc_queue,
|
|
info=Info.NORMAL_DRO,
|
|
mode=Modes.NORMAL,
|
|
submode=NormalSubmodes.DRO_ON,
|
|
)
|
|
if op_code in OpCodes.NORMAL_X8:
|
|
pack_pl_pcdu_mode_cmd(
|
|
tc_queue=tc_queue,
|
|
info=Info.NORMAL_X8,
|
|
mode=Modes.NORMAL,
|
|
submode=NormalSubmodes.X8_ON,
|
|
)
|
|
if op_code in OpCodes.NORMAL_TX:
|
|
pack_pl_pcdu_mode_cmd(
|
|
tc_queue=tc_queue,
|
|
info=Info.NORMAL_TX,
|
|
mode=Modes.NORMAL,
|
|
submode=NormalSubmodes.TX_ON,
|
|
)
|
|
if op_code in OpCodes.NORMAL_MPA:
|
|
pack_pl_pcdu_mode_cmd(
|
|
tc_queue=tc_queue,
|
|
info=Info.NORMAL_MPA,
|
|
mode=Modes.NORMAL,
|
|
submode=NormalSubmodes.MPA_ON,
|
|
)
|
|
if op_code in OpCodes.NORMAL_HPA:
|
|
pack_pl_pcdu_mode_cmd(
|
|
tc_queue=tc_queue,
|
|
info=Info.NORMAL_HPA,
|
|
mode=Modes.NORMAL,
|
|
submode=NormalSubmodes.HPA_ON,
|
|
)
|
|
if op_code in OpCodes.UPDATE_DRO_TO_X8_WAIT:
|
|
pack_wait_time_cmd(
|
|
tc_queue=tc_queue,
|
|
param_id=ParamIds.DRO_TO_X8_WAIT_TIME,
|
|
print_str="DRO to X8",
|
|
)
|
|
if op_code in OpCodes.UPDATE_X8_TO_TX_WAIT_TIME:
|
|
pack_wait_time_cmd(
|
|
tc_queue=tc_queue,
|
|
param_id=ParamIds.X8_TO_TX_WAIT_TIME,
|
|
print_str="X8 to TX",
|
|
)
|
|
if op_code in OpCodes.UPDATE_TX_TO_MPA_WAIT_TIME:
|
|
pack_wait_time_cmd(
|
|
tc_queue=tc_queue,
|
|
param_id=ParamIds.TX_TO_MPA_WAIT_TIME,
|
|
print_str="TX to MPA",
|
|
)
|
|
if op_code in OpCodes.UPDATE_MPA_TO_HPA_WAIT_TIME:
|
|
pack_wait_time_cmd(
|
|
tc_queue=tc_queue,
|
|
param_id=ParamIds.MPA_TO_HPA_WAIT_TIME,
|
|
print_str="MPA to HPA",
|
|
)
|
|
if op_code in OpCodes.INJECT_ALL_ON_FAILURE:
|
|
pack_failure_injection_cmd(
|
|
tc_queue=tc_queue,
|
|
param_id=ParamIds.INJECT_ALL_ON_FAILURE,
|
|
print_str="All On",
|
|
)
|
|
|
|
|
|
def request_wait_time() -> Optional[float]:
|
|
while True:
|
|
wait_time = input("Please enter DRO to X8 wait time in seconds, x to cancel: ")
|
|
if wait_time.lower() == "x":
|
|
return None
|
|
try:
|
|
wait_time = float(wait_time)
|
|
except ValueError:
|
|
LOGGER.warning("Invalid input")
|
|
continue
|
|
if wait_time <= 0:
|
|
LOGGER.warning("Invalid input")
|
|
else:
|
|
return wait_time
|
|
|
|
|
|
def pack_wait_time_cmd(tc_queue: TcQueueT, param_id: int, print_str: str):
|
|
wait_time = request_wait_time()
|
|
tc_queue.appendleft(
|
|
(QueueCommands.PRINT, f"Updating {print_str} wait time to {wait_time}")
|
|
)
|
|
if wait_time is None:
|
|
return
|
|
param_data = pack_scalar_double_param_app_data(
|
|
object_id=PL_PCDU_ID,
|
|
domain_id=0,
|
|
unique_id=param_id,
|
|
parameter=wait_time,
|
|
)
|
|
cmd = pack_fsfw_load_param_cmd(ssc=0, app_data=param_data)
|
|
tc_queue.appendleft(cmd.pack_command_tuple())
|
|
|
|
|
|
def pack_failure_injection_cmd(tc_queue: TcQueueT, param_id: int, print_str: str):
|
|
tc_queue.appendleft((QueueCommands.PRINT, f"Inserting {print_str} error"))
|
|
param_data = pack_boolean_parameter_app_data(
|
|
object_id=PL_PCDU_ID, domain_id=0, unique_id=param_id, parameter=True
|
|
)
|
|
cmd = pack_fsfw_load_param_cmd(ssc=0, app_data=param_data)
|
|
tc_queue.appendleft(cmd.pack_command_tuple())
|
|
|
|
|
|
def pack_pl_pcdu_mode_cmd(tc_queue: TcQueueT, info: str, mode: int, submode: int):
|
|
tc_queue.appendleft(
|
|
(
|
|
QueueCommands.PRINT,
|
|
info,
|
|
)
|
|
)
|
|
mode_data = pack_mode_data(object_id=PL_PCDU_ID, mode=mode, submode=submode)
|
|
mode_cmd = PusTelecommand(
|
|
service=200, subservice=Subservices.COMMAND_MODE_COMMAND, app_data=mode_data
|
|
)
|
|
tc_queue.appendleft(mode_cmd.pack_command_tuple())
|