303 lines
11 KiB
Python
303 lines
11 KiB
Python
import datetime
|
|
import enum
|
|
import logging
|
|
import struct
|
|
|
|
from eive_tmtc.config.definitions import CustomServiceList
|
|
from eive_tmtc.config.object_ids import PWR_CONTROLLER
|
|
from eive_tmtc.pus_tm.defs import PrintWrapper
|
|
from tmtccmd.config.tmtc import (
|
|
tmtc_definitions_provider,
|
|
TmtcDefinitionWrapper,
|
|
OpCodeEntry,
|
|
)
|
|
from tmtccmd.tmtc import service_provider
|
|
from tmtccmd.tmtc.queue import DefaultPusQueueHelper
|
|
from tmtccmd.pus.s200_fsfw_mode import Mode, pack_mode_command
|
|
from tmtccmd.tmtc.decorator import ServiceProviderParams
|
|
from tmtccmd.pus.tc.s3_fsfw_hk import (
|
|
generate_one_hk_command,
|
|
make_sid,
|
|
enable_periodic_hk_command_with_interval,
|
|
disable_periodic_hk_command,
|
|
)
|
|
from tmtccmd.fsfw.tmtc_printer import FsfwTmTcPrinter
|
|
|
|
from tmtccmd.pus.s20_fsfw_param import create_load_param_cmd
|
|
|
|
from tmtccmd.pus.s20_fsfw_param_defs import (
|
|
create_scalar_float_parameter,
|
|
create_scalar_double_parameter,
|
|
)
|
|
|
|
_LOGGER = logging.getLogger(__name__)
|
|
|
|
|
|
class SetId(enum.IntEnum):
|
|
CORE_HK_SET = 0
|
|
ENABLE_PL_SET = 1
|
|
|
|
|
|
# class ActionId(enum.IntEnum):
|
|
|
|
|
|
class ParamId(enum.IntEnum):
|
|
BATTERY_INTERNAL_RESISTANCE = 0
|
|
BATTERY_MAXIMUM_CAPACITY = 1
|
|
COULOMB_COUNTER_VOLTAGE_UPPER_THRESHOLD = 2
|
|
MAX_ALLOWED_TIME_DIFF = 3
|
|
PAYLOAD_OP_LIMIT_ON = 4
|
|
PAYLOAD_OP_LIMIT_LOW = 5
|
|
HIGHER_MODES_LIMIT = 6
|
|
|
|
|
|
class OpCodes:
|
|
OFF = ["mode_off"]
|
|
ON = ["mode_on"]
|
|
NML = ["mode_normal"]
|
|
SET_PARAMETER = ["set_parameter"]
|
|
REQUEST_CORE_HK = ["core_hk"]
|
|
ENABLE_CORE_HK = ["core_enable_hk"]
|
|
DISABLE_CORE_HK = ["core_disable_hk"]
|
|
REQUEST_ENABLE_PL_HK = ["enable_pl_hk"]
|
|
ENABLE_ENABLE_PL_HK = ["enable_pl_enable_hk"]
|
|
DISABLE_ENABLE_PL_HK = ["enable_pl_disable_hk"]
|
|
|
|
|
|
class Info:
|
|
OFF = "PWR Ctrl Mode to OFF"
|
|
ON = "PWR Ctrl Mode to ON"
|
|
NML = "PWR Ctrl Mode to NORMAL"
|
|
SET_PARAMETER = "Set Parameter"
|
|
REQUEST_CORE_HK = "Request Core HK once"
|
|
ENABLE_CORE_HK = "Enable Core HK Data Generation"
|
|
DISABLE_CORE_HK = "Disable Core HK Data Generation"
|
|
REQUEST_ENABLE_PL_HK = "Request Enable PL HK once"
|
|
ENABLE_ENABLE_PL_HK = "Enable Enable PL HK Data Generation"
|
|
DISABLE_ENABLE_PL_HK = "Disable Enable PL HK Data Generation"
|
|
|
|
|
|
@tmtc_definitions_provider
|
|
def pwr_cmd_defs(defs: TmtcDefinitionWrapper):
|
|
oce = OpCodeEntry()
|
|
oce.add(keys=OpCodes.OFF, info=Info.OFF)
|
|
oce.add(keys=OpCodes.ON, info=Info.ON)
|
|
oce.add(keys=OpCodes.NML, info=Info.NML)
|
|
oce.add(keys=OpCodes.SET_PARAMETER, info=Info.SET_PARAMETER)
|
|
oce.add(keys=OpCodes.REQUEST_CORE_HK, info=Info.REQUEST_CORE_HK)
|
|
oce.add(keys=OpCodes.ENABLE_CORE_HK, info=Info.ENABLE_CORE_HK)
|
|
oce.add(keys=OpCodes.DISABLE_CORE_HK, info=Info.DISABLE_CORE_HK)
|
|
oce.add(keys=OpCodes.REQUEST_ENABLE_PL_HK, info=Info.REQUEST_ENABLE_PL_HK)
|
|
oce.add(keys=OpCodes.ENABLE_ENABLE_PL_HK, info=Info.ENABLE_ENABLE_PL_HK)
|
|
oce.add(keys=OpCodes.DISABLE_ENABLE_PL_HK, info=Info.DISABLE_ENABLE_PL_HK)
|
|
defs.add_service(
|
|
name=CustomServiceList.PWR_CTRL.value, info="PWR Controller", op_code_entry=oce
|
|
)
|
|
|
|
|
|
@service_provider(CustomServiceList.PWR_CTRL.value)
|
|
def pack_acs_ctrl_command(p: ServiceProviderParams):
|
|
op_code = p.op_code
|
|
q = p.queue_helper
|
|
if op_code in OpCodes.OFF:
|
|
q.add_log_cmd(f"{Info.OFF}")
|
|
q.add_pus_tc(pack_mode_command(PWR_CONTROLLER, Mode.OFF, 0))
|
|
elif op_code in OpCodes.ON:
|
|
q.add_log_cmd(f"{Info.ON}")
|
|
q.add_pus_tc(pack_mode_command(PWR_CONTROLLER, Mode.ON, 0))
|
|
elif op_code in OpCodes.NML:
|
|
q.add_log_cmd(f"{Info.NML}")
|
|
q.add_pus_tc(pack_mode_command(PWR_CONTROLLER, Mode.NORMAL, 0))
|
|
elif op_code in OpCodes.SET_PARAMETER:
|
|
q.add_log_cmd(f"{Info.SET_PARAMETER}")
|
|
set_pwr_ctrl_param(q)
|
|
elif op_code in OpCodes.REQUEST_CORE_HK:
|
|
q.add_log_cmd(Info.REQUEST_CORE_HK)
|
|
q.add_pus_tc(
|
|
generate_one_hk_command(make_sid(PWR_CONTROLLER, SetId.CORE_HK_SET))
|
|
)
|
|
elif op_code in OpCodes.ENABLE_CORE_HK:
|
|
interval = float(input("Please specify interval in floating point seconds: "))
|
|
q.add_log_cmd(Info.ENABLE_CORE_HK)
|
|
cmd_tuple = enable_periodic_hk_command_with_interval(
|
|
False, make_sid(PWR_CONTROLLER, SetId.CORE_HK_SET), interval
|
|
)
|
|
q.add_pus_tc(cmd_tuple[0])
|
|
q.add_pus_tc(cmd_tuple[1])
|
|
elif op_code in OpCodes.DISABLE_CORE_HK:
|
|
q.add_log_cmd(Info.DISABLE_CORE_HK)
|
|
q.add_pus_tc(
|
|
disable_periodic_hk_command(
|
|
False, make_sid(PWR_CONTROLLER, SetId.CORE_HK_SET)
|
|
)
|
|
)
|
|
elif op_code in OpCodes.REQUEST_ENABLE_PL_HK:
|
|
q.add_log_cmd(Info.REQUEST_ENABLE_PL_HK)
|
|
q.add_pus_tc(
|
|
generate_one_hk_command(make_sid(PWR_CONTROLLER, SetId.ENABLE_PL_SET))
|
|
)
|
|
elif op_code in OpCodes.ENABLE_ENABLE_PL_HK:
|
|
interval = float(input("Please specify interval in floating point seconds: "))
|
|
q.add_log_cmd(Info.ENABLE_ENABLE_PL_HK)
|
|
cmd_tuple = enable_periodic_hk_command_with_interval(
|
|
False, make_sid(PWR_CONTROLLER, SetId.ENABLE_PL_SET), interval
|
|
)
|
|
q.add_pus_tc(cmd_tuple[0])
|
|
q.add_pus_tc(cmd_tuple[1])
|
|
elif op_code in OpCodes.DISABLE_ENABLE_PL_HK:
|
|
q.add_log_cmd(Info.DISABLE_ENABLE_PL_HK)
|
|
q.add_pus_tc(
|
|
disable_periodic_hk_command(
|
|
False, make_sid(PWR_CONTROLLER, SetId.ENABLE_PL_SET)
|
|
)
|
|
)
|
|
|
|
|
|
def set_pwr_ctrl_param(q: DefaultPusQueueHelper):
|
|
for val in ParamId:
|
|
print("{:<2}: {:<20}".format(val, val.name))
|
|
param = int(input("Specify parameter to set \n" ""))
|
|
match param:
|
|
case ParamId.BATTERY_INTERNAL_RESISTANCE:
|
|
value = float(input("Specify parameter value to set [Ohm]: "))
|
|
q.add_pus_tc(
|
|
create_load_param_cmd(
|
|
create_scalar_float_parameter(
|
|
object_id=PWR_CONTROLLER,
|
|
domain_id=0,
|
|
unique_id=ParamId.BATTERY_INTERNAL_RESISTANCE,
|
|
parameter=value,
|
|
)
|
|
)
|
|
)
|
|
case ParamId.BATTERY_MAXIMUM_CAPACITY:
|
|
value = float(input("Specify parameter value to set [Ah]: "))
|
|
q.add_pus_tc(
|
|
create_load_param_cmd(
|
|
create_scalar_float_parameter(
|
|
object_id=PWR_CONTROLLER,
|
|
domain_id=0,
|
|
unique_id=ParamId.BATTERY_MAXIMUM_CAPACITY,
|
|
parameter=value,
|
|
)
|
|
)
|
|
)
|
|
case ParamId.COULOMB_COUNTER_VOLTAGE_UPPER_THRESHOLD:
|
|
value = float(input("Specify parameter value to set [V]: "))
|
|
q.add_pus_tc(
|
|
create_load_param_cmd(
|
|
create_scalar_float_parameter(
|
|
object_id=PWR_CONTROLLER,
|
|
domain_id=0,
|
|
unique_id=ParamId.COULOMB_COUNTER_VOLTAGE_UPPER_THRESHOLD,
|
|
parameter=value,
|
|
)
|
|
)
|
|
)
|
|
case ParamId.MAX_ALLOWED_TIME_DIFF:
|
|
value = float(input("Specify parameter value to set [s]: "))
|
|
q.add_pus_tc(
|
|
create_load_param_cmd(
|
|
create_scalar_double_parameter(
|
|
object_id=PWR_CONTROLLER,
|
|
domain_id=0,
|
|
unique_id=ParamId.MAX_ALLOWED_TIME_DIFF,
|
|
parameter=value,
|
|
)
|
|
)
|
|
)
|
|
case ParamId.PAYLOAD_OP_LIMIT_ON:
|
|
value = float(input("Specify parameter value to set [1]: "))
|
|
q.add_pus_tc(
|
|
create_load_param_cmd(
|
|
create_scalar_float_parameter(
|
|
object_id=PWR_CONTROLLER,
|
|
domain_id=0,
|
|
unique_id=ParamId.PAYLOAD_OP_LIMIT_ON,
|
|
parameter=value,
|
|
)
|
|
)
|
|
)
|
|
case ParamId.PAYLOAD_OP_LIMIT_LOW:
|
|
value = float(input("Specify parameter value to set [1]: "))
|
|
q.add_pus_tc(
|
|
create_load_param_cmd(
|
|
create_scalar_float_parameter(
|
|
object_id=PWR_CONTROLLER,
|
|
domain_id=0,
|
|
unique_id=ParamId.PAYLOAD_OP_LIMIT_LOW,
|
|
parameter=value,
|
|
)
|
|
)
|
|
)
|
|
case ParamId.HIGHER_MODES_LIMIT:
|
|
value = float(input("Specify parameter value to set [1]: "))
|
|
q.add_pus_tc(
|
|
create_load_param_cmd(
|
|
create_scalar_float_parameter(
|
|
object_id=PWR_CONTROLLER,
|
|
domain_id=0,
|
|
unique_id=ParamId.HIGHER_MODES_LIMIT,
|
|
parameter=value,
|
|
)
|
|
)
|
|
)
|
|
|
|
|
|
def handle_pwr_ctrl_hk_data(
|
|
pw: PrintWrapper,
|
|
set_id: int,
|
|
hk_data: bytes,
|
|
packet_time: datetime.datetime,
|
|
):
|
|
pw.ilog(_LOGGER, f"Received PWR CTRL HK with packet time {packet_time}")
|
|
match set_id:
|
|
case SetId.CORE_HK_SET:
|
|
handle_core_hk_data(pw, hk_data)
|
|
case SetId.ENABLE_PL_SET:
|
|
handle_enable_pl_data(pw, hk_data)
|
|
|
|
|
|
def handle_core_hk_data(pw: PrintWrapper, hk_data: bytes):
|
|
pw.dlog("Received Core HK Set")
|
|
fmt_int16 = "!h"
|
|
fmt_float = "!f"
|
|
inc_len_int16 = struct.calcsize(fmt_int16)
|
|
inc_len_float = struct.calcsize(fmt_float)
|
|
if len(hk_data) < inc_len_int16 + 2 * inc_len_float:
|
|
pw.dlog("Received HK set too small")
|
|
return
|
|
current_idx = 0
|
|
total_battery_current = struct.unpack(
|
|
fmt_int16, hk_data[current_idx : current_idx + inc_len_int16]
|
|
)[0]
|
|
current_idx += inc_len_int16
|
|
open_circuit_voltage_charge = struct.unpack(
|
|
fmt_float, hk_data[current_idx : current_idx + inc_len_float]
|
|
)[0]
|
|
current_idx += inc_len_float
|
|
coulomb_counter_charge = struct.unpack(
|
|
fmt_float, hk_data[current_idx : current_idx + inc_len_float]
|
|
)[0]
|
|
current_idx += inc_len_float
|
|
pw.dlog(f"Total Battery Current: {total_battery_current} [mA]")
|
|
pw.dlog(f"Open Circuit Voltage Charge: {open_circuit_voltage_charge*100:8.3f} [%]")
|
|
pw.dlog(f"Coulomb Counter Charge: {coulomb_counter_charge*100:8.3f} [%]")
|
|
FsfwTmTcPrinter.get_validity_buffer(hk_data[current_idx:], num_vars=3)
|
|
|
|
|
|
def handle_enable_pl_data(pw: PrintWrapper, hk_data: bytes):
|
|
pw.dlog("Received Enable PL HK Set")
|
|
fmt_uint16 = "!B"
|
|
inc_len_uint16 = struct.calcsize(fmt_uint16)
|
|
if len(hk_data) < inc_len_uint16:
|
|
pw.dlog("Received HK set too small")
|
|
return
|
|
current_idx = 0
|
|
pl_use_allowed = struct.unpack(
|
|
fmt_uint16, hk_data[current_idx : current_idx + inc_len_uint16]
|
|
)[0]
|
|
current_idx += inc_len_uint16
|
|
pw.dlog(f"PL Use Allowed: {pl_use_allowed}")
|
|
FsfwTmTcPrinter.get_validity_buffer(hk_data[current_idx:], num_vars=1)
|