eive-tmtc/eive_tmtc/tmtc/com/pdec_handler.py
Robin Mueller dccbf89da1
All checks were successful
EIVE/-/pipeline/head This commit looks good
some more fixes
2024-05-08 10:49:20 +02:00

126 lines
4.1 KiB
Python

# -*- coding: utf-8 -*-
"""
@file pdec_handler.py
@brief Test commanding of PDEC Handler
@author J. Meier
@date 22.11.2021
"""
import enum
from spacepackets.ecss.tc import PusTelecommand
from tmtccmd.tmtc import DefaultPusQueueHelper
from tmtccmd.pus.s20_fsfw_param import create_load_param_cmd
from tmtccmd.pus.s8_fsfw_action import create_action_cmd
from tmtccmd.pus.s20_fsfw_param_defs import create_scalar_u8_parameter
from tmtccmd.config.tmtc import (
tmtc_definitions_provider,
TmtcDefinitionWrapper,
OpCodeEntry,
)
from eive_tmtc.config.definitions import CustomServiceList
class CommandId:
# prints the clcw to the console. Useful for debugging
PRINT_CLCW = bytearray([0x0, 0x0, 0x0, 0x0])
# Print PDEC monitor register
PRINT_PDEC_MON = bytearray([0x0, 0x0, 0x0, 0x1])
class ParameterId(enum.IntEnum):
POSITIVE_WINDOW = 0
NEGATIVE_WINDOW = 1
class ActionId(enum.IntEnum):
RESET_NO_INIT = 2
RESET_WITH_INIT = 3
class OpCode:
PRINT_CLCW = "print_clcw"
PRINT_MON_REG = "print_mon_reg"
POSITIVE_WINDOW = "positive_window"
NEGATIVE_WINDOW = "negative_window"
RESET_WITH_INIT = "reset_with_init"
RESET_NO_INIT = "reset_no_init"
class Info:
PRINT_CLCW = "Will cause the OBSW to print the current CLCW to the debug console"
PRINT_MON_REG = (
"Will cause the OBSW to print the PDEC monitor register to the console"
)
POSITIVE_WINDOW = "Change positive window parameter for AD frames"
NEGATIVE_WINDOW = "Change negative window parameter for AD frames"
RESET_WITH_INIT = "Reset with full initialization"
RESET_NO_INIT = "Reset with mandatory initialization"
def pack_pdec_handler_commands(
object_id: bytes, q: DefaultPusQueueHelper, cmd_str: str
):
q.add_log_cmd(f"Testing PDEC handler with object id: {object_id.hex()}")
prefix = "PDEC Handler "
if cmd_str == OpCode.PRINT_CLCW:
q.add_log_cmd(f"{prefix}: {Info.PRINT_CLCW}")
command = object_id + CommandId.PRINT_CLCW
q.add_pus_tc(PusTelecommand(service=8, subservice=128, app_data=command))
if cmd_str == OpCode.PRINT_MON_REG:
q.add_log_cmd(f"{prefix}: {Info.PRINT_MON_REG}")
command = object_id + CommandId.PRINT_PDEC_MON
q.add_pus_tc(PusTelecommand(service=8, subservice=128, app_data=command))
if cmd_str == OpCode.POSITIVE_WINDOW:
q.add_log_cmd(f"{prefix}: {Info.POSITIVE_WINDOW}")
pw = int(input("Specify positive window to set: "))
q.add_pus_tc(
create_load_param_cmd(
parameter=create_scalar_u8_parameter(
object_id,
0,
ParameterId.POSITIVE_WINDOW,
pw,
),
apid=0,
)
)
if cmd_str == OpCode.NEGATIVE_WINDOW:
q.add_log_cmd(f"{prefix}: {Info.NEGATIVE_WINDOW}")
nw = int(input("Specify negative window to set: "))
q.add_pus_tc(
create_load_param_cmd(
parameter=create_scalar_u8_parameter(
object_id,
0,
ParameterId.NEGATIVE_WINDOW,
nw,
),
apid=0,
)
)
if cmd_str == OpCode.RESET_NO_INIT:
q.add_log_cmd(f"{prefix}: {Info.RESET_NO_INIT}")
q.add_pus_tc(
create_action_cmd(object_id=object_id, action_id=ActionId.RESET_NO_INIT)
)
if cmd_str == OpCode.RESET_WITH_INIT:
q.add_log_cmd(f"{prefix}: {Info.RESET_WITH_INIT}")
q.add_pus_tc(
create_action_cmd(object_id=object_id, action_id=ActionId.RESET_WITH_INIT)
)
@tmtc_definitions_provider
def add_pdec_cmds(defs: TmtcDefinitionWrapper):
oce = OpCodeEntry()
oce.add(OpCode.PRINT_CLCW, Info.PRINT_CLCW)
oce.add(OpCode.PRINT_MON_REG, Info.PRINT_MON_REG)
oce.add(OpCode.POSITIVE_WINDOW, Info.POSITIVE_WINDOW)
oce.add(OpCode.NEGATIVE_WINDOW, Info.NEGATIVE_WINDOW)
oce.add(OpCode.RESET_WITH_INIT, Info.RESET_WITH_INIT)
oce.add(OpCode.RESET_NO_INIT, Info.RESET_NO_INIT)
defs.add_service(CustomServiceList.PDEC_HANDLER.value, "PDEC Handler", oce)