eive-tmtc/eive_tmtc/tmtc/tcs.py

236 lines
8.2 KiB
Python

import enum
import pprint
import struct
from eive_tmtc.pus_tm.defs import PrintWrapper
from eive_tmtc.config.definitions import CustomServiceList
from tmtccmd.config import TmtcDefinitionWrapper, OpCodeEntry
from tmtccmd.config.tmtc import tmtc_definitions_provider
from tmtccmd.tc import DefaultPusQueueHelper
from tmtccmd.tc.pus_200_fsfw_modes import Mode
from tmtccmd.tc.pus_3_fsfw_hk import (
make_sid,
generate_one_hk_command,
)
from eive_tmtc.tmtc.common import pack_mode_cmd_with_info
from eive_tmtc.config.object_ids import (
TCS_BOARD_ASS_ID,
TCS_CONTROLLER,
TCS_SUBSYSTEM_ID,
)
from tmtccmd.util import ObjectIdU32
from tmtccmd.util.tmtc_printer import FsfwTmTcPrinter
class OpCodeAssy:
TCS_BOARD_ASS_NORMAL = ["nml"]
TCS_BOARD_ASS_OFF = ["off"]
class OpCodeSys:
OFF = ["off"]
NML = ["nml"]
REQUEST_PRIMARY_TEMP_SET = ["temp"]
REQUEST_DEVICE_TEMP_SET = ["temp_devs"]
REQUEST_DEVICE_SUS_SET = ["temp_sus"]
class InfoSys:
OFF = "Switch TCS subsystem OFF"
NML = "Switch TCS subsystem NORMAL (nominal)"
REQUEST_PRIMARY_TEMP_SET = "Request HK set of primary sensor temperatures"
REQUEST_DEVICE_TEMP_SET = "Request HK set of device sensor temperatures"
REQUEST_DEVICE_SUS_SET = "Request HK set of the SUS temperatures"
class InfoAssy:
TCS_BOARD_ASS_NORMAL = "Switching TCS board assembly on"
TCS_BOARD_ASS_OFF = "Switching TCS board assembly off"
class SetId(enum.IntEnum):
PRIMARY_SENSORS = 0
DEVICE_SENSORS = 1
SUS_TEMP_SENSORS = 2
@tmtc_definitions_provider
def add_tcs_cmds(defs: TmtcDefinitionWrapper):
oce = OpCodeEntry()
oce.add(
keys=OpCodeAssy.TCS_BOARD_ASS_NORMAL,
info=InfoAssy.TCS_BOARD_ASS_NORMAL,
)
oce.add(
keys=OpCodeAssy.TCS_BOARD_ASS_OFF,
info=InfoAssy.TCS_BOARD_ASS_OFF,
)
defs.add_service(
name=CustomServiceList.TCS_ASS.value,
info="TCS Board Assembly",
op_code_entry=oce,
)
oce = OpCodeEntry()
oce.add(keys=OpCodeSys.OFF, info=InfoSys.OFF)
oce.add(keys=OpCodeSys.NML, info=InfoSys.NML)
oce.add(
keys=OpCodeSys.REQUEST_PRIMARY_TEMP_SET, info=InfoSys.REQUEST_PRIMARY_TEMP_SET
)
oce.add(
keys=OpCodeSys.REQUEST_DEVICE_TEMP_SET, info=InfoSys.REQUEST_DEVICE_TEMP_SET
)
oce.add(keys=OpCodeSys.REQUEST_DEVICE_SUS_SET, info=InfoSys.REQUEST_DEVICE_SUS_SET)
defs.add_service(
name=CustomServiceList.TCS,
info="TCS Board",
op_code_entry=oce,
)
def pack_tcs_sys_commands(q: DefaultPusQueueHelper, op_code: str):
if op_code in OpCodeSys.REQUEST_PRIMARY_TEMP_SET:
sensor_set_sid = make_sid(TCS_CONTROLLER, SetId.PRIMARY_SENSORS)
q.add_log_cmd(InfoSys.REQUEST_PRIMARY_TEMP_SET)
q.add_pus_tc(generate_one_hk_command(sensor_set_sid))
if op_code in OpCodeSys.REQUEST_DEVICE_TEMP_SET:
q.add_log_cmd(InfoSys.REQUEST_DEVICE_TEMP_SET)
q.add_pus_tc(
generate_one_hk_command(make_sid(TCS_CONTROLLER, SetId.DEVICE_SENSORS))
)
if op_code in OpCodeSys.REQUEST_DEVICE_SUS_SET:
q.add_log_cmd(InfoSys.REQUEST_DEVICE_SUS_SET)
q.add_pus_tc(
generate_one_hk_command(make_sid(TCS_CONTROLLER, SetId.SUS_TEMP_SENSORS))
)
if op_code in OpCodeSys.OFF:
q.add_log_cmd(InfoSys.OFF)
pack_mode_cmd_with_info(TCS_SUBSYSTEM_ID, Mode.OFF, 0, q, InfoSys.OFF)
if op_code in OpCodeSys.NML:
q.add_log_cmd(InfoSys.NML)
pack_mode_cmd_with_info(TCS_SUBSYSTEM_ID, Mode.NORMAL, 0, q, InfoSys.OFF)
pack_tcs_ass_cmds(q, op_code)
def pack_tcs_ass_cmds(q: DefaultPusQueueHelper, op_code: str):
if op_code in OpCodeAssy.TCS_BOARD_ASS_NORMAL:
pack_mode_cmd_with_info(
object_id=TCS_BOARD_ASS_ID,
mode=Mode.NORMAL,
submode=0,
q=q,
info=InfoAssy.TCS_BOARD_ASS_NORMAL,
)
if op_code in OpCodeAssy.TCS_BOARD_ASS_OFF:
pack_mode_cmd_with_info(
object_id=TCS_BOARD_ASS_ID,
mode=Mode.OFF,
submode=0,
q=q,
info=InfoAssy.TCS_BOARD_ASS_OFF,
)
def handle_thermal_controller_hk_data(
object_id: ObjectIdU32, printer: FsfwTmTcPrinter, set_id: int, hk_data: bytes
):
# need a better solutuon for this is this is used again..
"""
if TCP_TEMP_SENS_SERVER is None:
TCP_TEMP_SENS_SERVER = TmTcpServer("localhost", 7305)
if TCP_TEMP_DEV_SERVER:
TCP_TEMP_DEV_SERVER = TmTcpServer("localhost", 7306)
"""
if set_id == SetId.PRIMARY_SENSORS:
pw = PrintWrapper(printer)
pw.dlog("Received sensor temperature data")
# get all the floats
tm_data = struct.unpack("!fffffffffffffffffffff", hk_data[: 21 * 4])
parsed_data = {
"SENSOR_PLOC_HEATSPREADER": tm_data[0],
"SENSOR_PLOC_MISSIONBOARD": tm_data[1],
"SENSOR_4K_CAMERA": tm_data[2],
"SENSOR_DAC_HEATSPREADER": tm_data[3],
"SENSOR_STARTRACKER": tm_data[4],
"SENSOR_RW1": tm_data[5],
"SENSOR_DRO": tm_data[6],
"SENSOR_SCEX": tm_data[7],
"SENSOR_X8": tm_data[8],
"SENSOR_HPA": tm_data[9],
"SENSOR_TX_MODUL": tm_data[10],
"SENSOR_MPA": tm_data[11],
"SENSOR_ACU": tm_data[12],
"SENSOR_PLPCDU_HEATSPREADER": tm_data[13],
"SENSOR_TCS_BOARD": tm_data[14],
"SENSOR_MAGNETTORQUER": tm_data[15],
"TMP1075 TCS 0": tm_data[16],
"TMP1075 TCS 1": tm_data[17],
"TMP1075 PL PCDU 0": tm_data[18],
"TMP1075 PL PCDU 1": tm_data[19],
"TMP1075 IF BOARD": tm_data[20],
}
printer.file_logger.info(str(parsed_data))
pp = pprint.PrettyPrinter(depth=4)
pp.pprint(parsed_data)
elif set_id == SetId.DEVICE_SENSORS:
pw = PrintWrapper(printer)
pw.dlog("Received device temperature data")
fmt_str = "!fhhhhiiiifffhffffffffffffff"
tm_data = struct.unpack(fmt_str, hk_data[:98])
parsed_data = {
"Q7S_TEMPERATURE": tm_data[0],
"BATTERY_TEMPERATURE_1": tm_data[1],
"BATTERY_TEMPERATURE_2": tm_data[2],
"BATTERY_TEMPERATURE_3": tm_data[3],
"BATTERY_TEMPERATURE_4": tm_data[4],
"RW_1_TEMPERATURE": tm_data[5],
"RW_2_TEMPERATURE": tm_data[6],
"RW_3_TEMPERATURE": tm_data[7],
"RW_4_TEMPERATURE": tm_data[8],
"STARTRACKER_TEMPERATURE": tm_data[9],
"SYRLINKS_POWER_AMPLIFIER_TEMPERATURE": tm_data[10],
"SYRLINKS_BASEBAND_BOARD_TEMPERATURE": tm_data[11],
"MGT_TEMPERATURE": tm_data[12],
"ACU_TEMPERATURE_1": tm_data[13],
"ACU_TEMPERATURE_2": tm_data[14],
"ACU_TEMPERATURE_3": tm_data[15],
"PDU1_TEMPERATURE": tm_data[16],
"PDU2_TEMPERATURE": tm_data[17],
"P60DOCK_TEMPERATURE_1": tm_data[18],
"P60DOCK_TEMPERATURE_2": tm_data[19],
"GYRO_0_TEMPERATURE": tm_data[20],
"GYRO_1_TEMPERATURE": tm_data[21],
"GYRO_2_TEMPERATURE": tm_data[22],
"GYRO_3_TEMPERATURE": tm_data[23],
"MGM_0_TEMPERATURE": tm_data[24],
"MGM_1_TEMPERATURE": tm_data[25],
"ADC_PL_PCDU_TEMPERATURE": tm_data[26],
}
printer.file_logger.info(str(parsed_data))
pp = pprint.PrettyPrinter(depth=4)
pp.pprint(parsed_data)
elif set_id == SetId.SUS_TEMP_SENSORS:
pw = PrintWrapper(printer)
pw.dlog("Received SUS temperature data")
fmt_str = "!ffffffffffffffffff"
tm_data = struct.unpack(fmt_str, hk_data[: 4 * 18])
parsed_data = {
"SUS_0": tm_data[0],
"SUS_1": tm_data[1],
"SUS_2": tm_data[2],
"SUS_3": tm_data[3],
"SUS_4": tm_data[4],
"SUS_5": tm_data[5],
"SUS_6": tm_data[6],
"SUS_7": tm_data[7],
"SUS_8": tm_data[8],
"SUS_9": tm_data[9],
"SUS_10": tm_data[10],
"SUS_11": tm_data[11],
}
printer.file_logger.info(str(parsed_data))
pp = pprint.PrettyPrinter(depth=4)
pp.pprint(parsed_data)