#ifndef TEMPERATURESENSOR_H_
|
|
#define TEMPERATURESENSOR_H_
|
|
|
|
#include "../datapool/DataSet.h"
|
|
#include "AbstractTemperatureSensor.h"
|
|
#include "../monitoring/LimitMonitor.h"
|
|
|
|
template<typename T>
|
|
class TemperatureSensor: public AbstractTemperatureSensor {
|
|
public:
|
|
struct Parameters {
|
|
float a;
|
|
float b;
|
|
float c;
|
|
T lowerLimit;
|
|
T upperLimit;
|
|
float gradient;
|
|
};
|
|
struct UsedParameters {
|
|
UsedParameters(Parameters parameters) :
|
|
a(parameters.a), b(parameters.b), c(parameters.c), gradient(
|
|
parameters.gradient) {
|
|
}
|
|
float a;
|
|
float b;
|
|
float c;
|
|
float gradient;
|
|
};
|
|
|
|
static const uint16_t ADDRESS_A = 0;
|
|
static const uint16_t ADDRESS_B = 1;
|
|
static const uint16_t ADDRESS_C = 2;
|
|
static const uint16_t ADDRESS_GRADIENT = 3;
|
|
|
|
static const uint16_t DEFAULT_CONFIRMATION_COUNT = 1; //!< Changed due to issue with later temperature checking even tough the sensor monitor was confirming already (Was 10 before with comment = Correlates to a 10s confirmation time. Chosen rather large, should not be so bad for components and helps survive glitches.)
|
|
|
|
static const uint8_t DOMAIN_ID_SENSOR = 1;
|
|
private:
|
|
void setInvalid() {
|
|
outputTemperature = INVALID_TEMPERATURE;
|
|
outputTemperature.setValid(false);
|
|
uptimeOfOldTemperature.tv_sec = INVALID_UPTIME;
|
|
sensorMonitor.setToInvalid();
|
|
}
|
|
protected:
|
|
static const int32_t INVALID_UPTIME = 0;
|
|
|
|
UsedParameters parameters;
|
|
|
|
T *inputTemperature;
|
|
|
|
PoolVariableIF *poolVariable;
|
|
|
|
PoolVariable<float> outputTemperature;
|
|
|
|
LimitMonitor<T> sensorMonitor;
|
|
|
|
float oldTemperature;
|
|
timeval uptimeOfOldTemperature;
|
|
|
|
virtual float calculateOutputTemperature(T inputTemperature) {
|
|
return parameters.a * inputTemperature * inputTemperature
|
|
+ parameters.b * inputTemperature + parameters.c;
|
|
}
|
|
|
|
void doChildOperation() {
|
|
if (!poolVariable->isValid()
|
|
|| !healthHelper.healthTable->isHealthy(getObjectId())) {
|
|
setInvalid();
|
|
return;
|
|
}
|
|
|
|
outputTemperature = calculateOutputTemperature(*inputTemperature);
|
|
outputTemperature.setValid(PoolVariableIF::VALID);
|
|
|
|
timeval uptime;
|
|
Clock::getUptime(&uptime);
|
|
|
|
if (uptimeOfOldTemperature.tv_sec != INVALID_UPTIME) {
|
|
//In theory, we could use an AbsValueMonitor to monitor the gradient.
|
|
//But this would require storing the gradient in DP and quite some overhead.
|
|
//The concept of delta limits is a bit strange anyway.
|
|
float deltaTime;
|
|
float deltaTemp;
|
|
|
|
deltaTime = (uptime.tv_sec + uptime.tv_usec / 1000000.)
|
|
- (uptimeOfOldTemperature.tv_sec
|
|
+ uptimeOfOldTemperature.tv_usec / 1000000.);
|
|
deltaTemp = oldTemperature - outputTemperature;
|
|
if (deltaTemp < 0) {
|
|
deltaTemp = -deltaTemp;
|
|
}
|
|
if (parameters.gradient < deltaTemp / deltaTime) {
|
|
triggerEvent(TEMP_SENSOR_GRADIENT);
|
|
//Don't set invalid, as we did not recognize it as invalid with full authority, let FDIR handle it
|
|
}
|
|
}
|
|
|
|
//Check is done against raw limits. SHOULDDO: Why? Using °C would be more easy to handle.
|
|
sensorMonitor.doCheck(*inputTemperature);
|
|
|
|
if (sensorMonitor.isOutOfLimits()) {
|
|
uptimeOfOldTemperature.tv_sec = INVALID_UPTIME;
|
|
outputTemperature.setValid(PoolVariableIF::INVALID);
|
|
outputTemperature = INVALID_TEMPERATURE;
|
|
} else {
|
|
oldTemperature = outputTemperature;
|
|
uptimeOfOldTemperature = uptime;
|
|
}
|
|
}
|
|
|
|
public:
|
|
TemperatureSensor(object_id_t setObjectid,
|
|
T *inputTemperature, PoolVariableIF *poolVariable,
|
|
uint8_t vectorIndex, Parameters parameters, uint32_t datapoolId,
|
|
DataSet *outputSet, ThermalModuleIF *thermalModule) :
|
|
AbstractTemperatureSensor(setObjectid, thermalModule), parameters(
|
|
parameters), inputTemperature(inputTemperature), poolVariable(
|
|
poolVariable), outputTemperature(datapoolId, outputSet,
|
|
PoolVariableIF::VAR_WRITE), sensorMonitor(setObjectid,
|
|
DOMAIN_ID_SENSOR,
|
|
DataPool::poolIdAndPositionToPid(
|
|
poolVariable->getDataPoolId(), vectorIndex),
|
|
DEFAULT_CONFIRMATION_COUNT, parameters.lowerLimit,
|
|
parameters.upperLimit, TEMP_SENSOR_LOW, TEMP_SENSOR_HIGH), oldTemperature(
|
|
20), uptimeOfOldTemperature( { INVALID_TEMPERATURE, 0 }) {
|
|
|
|
}
|
|
|
|
float getTemperature() {
|
|
return outputTemperature;
|
|
}
|
|
|
|
bool isValid() {
|
|
return outputTemperature.isValid();
|
|
}
|
|
|
|
virtual ReturnValue_t getParameter(uint8_t domainId, uint16_t parameterId,
|
|
ParameterWrapper *parameterWrapper,
|
|
const ParameterWrapper *newValues, uint16_t startAtIndex) {
|
|
ReturnValue_t result = sensorMonitor.getParameter(domainId, parameterId,
|
|
parameterWrapper, newValues, startAtIndex);
|
|
if (result != INVALID_DOMAIN_ID) {
|
|
return result;
|
|
}
|
|
if (domainId != this->DOMAIN_ID_BASE) {
|
|
return INVALID_DOMAIN_ID;
|
|
}
|
|
switch (parameterId) {
|
|
case ADDRESS_A:
|
|
parameterWrapper->set(parameters.a);
|
|
break;
|
|
case ADDRESS_B:
|
|
parameterWrapper->set(parameters.b);
|
|
break;
|
|
case ADDRESS_C:
|
|
parameterWrapper->set(parameters.c);
|
|
break;
|
|
case ADDRESS_GRADIENT:
|
|
parameterWrapper->set(parameters.gradient);
|
|
break;
|
|
default:
|
|
return INVALID_MATRIX_ID;
|
|
}
|
|
return HasReturnvaluesIF::RETURN_OK;
|
|
}
|
|
|
|
virtual void resetOldState() {
|
|
sensorMonitor.setToUnchecked();
|
|
}
|
|
|
|
};
|
|
|
|
#endif /* TEMPERATURESENSOR_H_ */
|