Merge pull request 'RM3100 important bugfix' (#733) from eive/fsfw:rm3100_fixes into development

Reviewed-on: fsfw/fsfw#733
This commit is contained in:
Ulrich Mohr 2023-02-09 11:41:53 +01:00
commit f94987c46d
2 changed files with 3 additions and 1 deletions

View File

@ -18,6 +18,8 @@ and this project adheres to [Semantic Versioning](http://semver.org/).
- HAL MGM3100 Handler: Use axis specific gain/scaling factors. Previously,
only the X scaling factor was used.
PR: https://egit.irs.uni-stuttgart.de/fsfw/fsfw/pulls/724
- Bugfix for RM3100 MGM sensors. Z value was previously calculated
with bytes of the X value.
- DHB `setNormalDatapoolEntriesInvalid`: The default implementation did not set the validity
to false correctly because the `read` and `write` calls were missing.
- PUS TMTC creator module: Sequence flags were set to continuation segment (0b00) instead

View File

@ -325,7 +325,7 @@ ReturnValue_t MgmRM3100Handler::handleDataReadout(const uint8_t *packet) {
// trickery here to calculate the raw values first
int32_t fieldStrengthRawX = ((packet[1] << 24) | (packet[2] << 16) | (packet[3] << 8)) >> 8;
int32_t fieldStrengthRawY = ((packet[4] << 24) | (packet[5] << 16) | (packet[6] << 8)) >> 8;
int32_t fieldStrengthRawZ = ((packet[7] << 24) | (packet[8] << 16) | (packet[3] << 8)) >> 8;
int32_t fieldStrengthRawZ = ((packet[7] << 24) | (packet[8] << 16) | (packet[9] << 8)) >> 8;
// Now scale to physical value in microtesla
float fieldStrengthX = fieldStrengthRawX * scaleFactorX;