changelog correction
This commit is contained in:
parent
6b36ba8323
commit
a9bd792194
@ -26,6 +26,9 @@ change warranting a new major release:
|
||||
- Set GPS set entries to invalid on MODE_OFF command.
|
||||
- Bump FSFW for bugfix in `setNormalDatapoolEntriesInvalid` where the validity was not set to false
|
||||
properly
|
||||
- Fixed usage of uint instead of int for commanding MTQ. Also fixed the range in which the ACS Ctrl
|
||||
commands the MTQ to match the actual commanding range.
|
||||
PR: https://egit.irs.uni-stuttgart.de/eive/eive-obsw/pulls/363
|
||||
- Regression: Revert swap of SUS0 and SUS6. Those devices are on separate power lines. In a
|
||||
future fix, the calibration matrices of SUS0 and SUS6 will be swapped.
|
||||
|
||||
@ -47,9 +50,6 @@ TMTC rev: 15adb9bf2ec68304a4f87b8dd418c1a8353283a3
|
||||
|
||||
- Bugfix in FSFW where the sequence flags of the PUS packets were set to continuation segment (0b00)
|
||||
instead of unsegmented (0b11).
|
||||
- Fixed usage of uint instead of int for commanding MTQ. Also fixed the range in which the ACS Ctrl
|
||||
commands the MTQ to match the actual commanding range.
|
||||
PR: https://egit.irs.uni-stuttgart.de/eive/eive-obsw/pulls/363
|
||||
- Bugfix in FSFW where the MGM RM3100 value Z axis data was parse incorrectly.
|
||||
PR: https://egit.irs.uni-stuttgart.de/eive/fsfw/pulls/123
|
||||
|
||||
|