Merge pull request 'TCS Ctrl Time Limit not for Heaters in External Control' (#878) from tcs-ctrl-ignores-ext-ctrl into main
EIVE/eive-obsw/pipeline/head This commit looks good Details

Reviewed-on: #878
Reviewed-by: Robin Müller <muellerr@irs.uni-stuttgart.de>
This commit is contained in:
Marius Eggert 2024-03-18 11:36:32 +01:00
commit a9f5b6d2c7
3 changed files with 17 additions and 3 deletions

View File

@ -22,10 +22,18 @@ will consitute of a breaking change warranting a new major release:
- Added parameter to disable STR input for MEKF.
## Changed
- If a primary heater is set to `EXTERNAL CONTROL` and `ON`, the `TCS Controller` will no
try to control the temperature of that object.
- Set lower OP limit of `PLOC` to -5°C.
## Fixed
- Added prevention of sign jump for target quaternion of GS pointing, which would reduce the
performance of the controller.
- Heaters set to `EXTERNAL CONTROL` no longer can be switched off by the `TCS Controller`, if
they violate the maximum burn duration of the controller.
# [v7.7.2] 2024-03-06

View File

@ -1641,7 +1641,11 @@ bool ThermalController::chooseHeater(heater::Switch& switchNr, heater::Switch re
bool heaterAvailable = true;
HasHealthIF::HealthState mainHealth = heaterHandler.getHealth(switchNr);
heater::SwitchState mainState = heaterHandler.getSwitchState(switchNr);
HasHealthIF::HealthState redHealth = heaterHandler.getHealth(redSwitchNr);
if (mainHealth == HasHealthIF::EXTERNAL_CONTROL and mainState == heater::SwitchState::ON) {
return false;
}
if (mainHealth != HasHealthIF::HEALTHY) {
if (redHealth == HasHealthIF::HEALTHY) {
switchNr = redSwitchNr;
@ -1656,6 +1660,7 @@ bool ThermalController::chooseHeater(heater::Switch& switchNr, heater::Switch re
} else {
ctrlCtx.redSwitchNrInUse = false;
}
return heaterAvailable;
}
@ -1792,7 +1797,8 @@ void ThermalController::heaterMaxDurationControl(
for (unsigned i = 0; i < heater::Switch::NUMBER_OF_SWITCHES; i++) {
// Right now, we only track the maximum duration for heater which were commanded by the TCS
// controller.
if (currentHeaterStates[i] == heater::SwitchState::ON and
if (heaterHandler.getHealth(static_cast<heater::Switch>(i)) != HasHealthIF::EXTERNAL_CONTROL and
currentHeaterStates[i] == heater::SwitchState::ON and
heaterStates[i].trackHeaterMaxBurnTime and
heaterStates[i].heaterOnMaxBurnTime.hasTimedOut()) {
heaterStates[i].switchTransition = false;

View File

@ -197,9 +197,9 @@ class ThermalController : public ExtendedControllerBase {
tcsCtrl::TempLimits pcduAcuLimits = tcsCtrl::TempLimits(-35.0, -35.0, 80.0, 85.0, 85.0);
tcsCtrl::TempLimits pcduPduLimits = tcsCtrl::TempLimits(-35.0, -35.0, 80.0, 85.0, 85.0);
tcsCtrl::TempLimits plPcduBoardLimits = tcsCtrl::TempLimits(-55.0, -40.0, 80.0, 85.0, 125.0);
tcsCtrl::TempLimits plocMissionBoardLimits = tcsCtrl::TempLimits(-30.0, -10.0, 40.0, 45.0, 60);
tcsCtrl::TempLimits plocMissionBoardLimits = tcsCtrl::TempLimits(-30.0, -5.0, 40.0, 45.0, 60);
tcsCtrl::TempLimits plocProcessingBoardLimits =
tcsCtrl::TempLimits(-30.0, -10.0, 40.0, 45.0, 60.0);
tcsCtrl::TempLimits(-30.0, -5.0, 40.0, 45.0, 60.0);
tcsCtrl::TempLimits dacLimits = tcsCtrl::TempLimits(-65.0, -40.0, 113.0, 118.0, 150.0);
tcsCtrl::TempLimits cameraLimits = tcsCtrl::TempLimits(-40.0, -30.0, 60.0, 65.0, 85.0);
tcsCtrl::TempLimits droLimits = tcsCtrl::TempLimits(-40.0, -30.0, 75.0, 80.0, 90.0);