Increase number of allowed parallel HK commands #678
@ -25,6 +25,10 @@ will consitute of a breaking change warranting a new major release:
|
||||
- TCS heater switch enumeration naming was old/wrong and was not updated in sync with the object ID
|
||||
update. This lead to the TCS controller commanding the wrong heaters.
|
||||
|
||||
## Changed
|
||||
|
||||
- Increase number of allowed parallel HK commands to 16
|
||||
|
||||
# [v3.0.0] 2023-06-11
|
||||
|
||||
- `eive-tmtc` version v4.0.0
|
||||
|
2
fsfw
2
fsfw
@ -1 +1 @@
|
||||
Subproject commit 5322de059916efcf874b10ccc766b46e53d2470b
|
||||
Subproject commit 0a977ea688cd78585aabb9ba511eaf8030452712
|
@ -238,7 +238,7 @@ void ObjectFactory::produceGenericObjects(HealthTableIF** healthTable_, PusTmFun
|
||||
new Service2DeviceAccess(objects::PUS_SERVICE_2_DEVICE_ACCESS, config::EIVE_PUS_APID,
|
||||
pus::PUS_SERVICE_2, 3, 10);
|
||||
new Service3Housekeeping(objects::PUS_SERVICE_3_HOUSEKEEPING, config::EIVE_PUS_APID,
|
||||
pus::PUS_SERVICE_3, config::HK_SERVICE_QUEUE_DEPTH);
|
||||
pus::PUS_SERVICE_3, config::HK_SERVICE_QUEUE_DEPTH, 16);
|
||||
new Service5EventReporting(
|
||||
PsbParams(objects::PUS_SERVICE_5_EVENT_REPORTING, config::EIVE_PUS_APID, pus::PUS_SERVICE_5),
|
||||
80, 160);
|
||||
|
Loading…
Reference in New Issue
Block a user