higher rx set rate during pass #715
@ -26,6 +26,7 @@ will consitute of a breaking change warranting a new major release:
|
||||
|
||||
- Internal error reporter set is now enabled by default and generated every 120 seconds.
|
||||
- Persistent TM store dumps are now performed in chronological order.
|
||||
- Increase Syrlinks RX HK rate to 5.0 seconds during a pass.
|
||||
- Various robustness improvements for the heater handler. The heater handler will now only
|
||||
process the command queue if it is not busy with switch commanding which reduces the amount
|
||||
of possible bugs.
|
||||
|
@ -773,11 +773,13 @@ void SyrlinksHandler::doTransition(Mode_t modeFrom, Submode_t subModeFrom) {
|
||||
auto txStandbyHandler = [&]() {
|
||||
txDataset.setReportingEnabled(false);
|
||||
poolManager.changeCollectionInterval(temperatureSet.getSid(), 60.0);
|
||||
poolManager.changeCollectionInterval(rxDataset.getSid(), 60.0);
|
||||
transState = TransitionState::SET_TX_STANDBY;
|
||||
internalState = InternalState::TX_TRANSITION;
|
||||
};
|
||||
auto txOnHandler = [&](TransitionState tgtTransitionState) {
|
||||
txDataset.setReportingEnabled(true);
|
||||
poolManager.changeCollectionInterval(rxDataset.getSid(), 5.0);
|
||||
poolManager.changeCollectionInterval(txDataset.getSid(), 10.0);
|
||||
poolManager.changeCollectionInterval(temperatureSet.getSid(), 5.0);
|
||||
transState = tgtTransitionState;
|
||||
|